Give us a call now: 22799067
  • 0Shopping Cart
setare arsh aria
  • Home
  • Chemical Test
    • pH / ORP
      • Tester pH / ORP
      • Portable pH / ORP
      • BenchTop pH / ORP
      • Online pH / ORP
    • EC / TDS
      • Tester EC / TDS
      • Portable EC / TDS
      • BenchTop EC / TDS
      • Online EC / TDS
    • DO (Dissolved Oxygen)
      • Portable DO
      • BenchTop DO
      • Online DO
    • Multiparameter
      • Tester Mutiparameter
      • Portable Multiparameter
      • BenchTop Multiparameter
      • Online Multiparameter
    • Turbidity
      • Portable Turbidity
      • BenchTop Turbidity
    • Photometer / Spectrophotometer
      • Checker
      • Portable Photometer
      • Bench Top Photometer
      • Spectrophotometer
      • COD
    • Titrator / Karl Fisher
      • Titrator
      • Karl Fisher
    • Refractometer
    • Electrodes
      • pH Electrodes
      • ORP Electrodes
      • EC/TDS Electrodes
      • DO Electrodes
      • ISE Electrodes
  • Agencies
  • Blog
    • Articles
    • Seminars
    • Exhibitions
  • Services
    • Guarantee & Warranty
    • Training & Installment
  • About
  • Contact
  • FA
  • Menu
HI83303 Multiparameter Photometer
HI83303 Multiparameter Photometer

HI83303 Multiparameter Photometer

HI83303 Multiparameter Photometer

HI83303 Multiparameter Photometer

HI83303 Multiparameter Photometer

 

HI-83303 Aquaculture Photometer with pH meter

Advanced optical system – Unparalleled performance from a benchtop photometer.

To save valuable benchtop space, the HI-83303 doubles as a professional pH meter with its digital pH/temperature electrode input. Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.

Categories: Bench Top Photometer, BenchTop Multiparameter, Multiparameter Tags: HI83303 hanna specification, HI83303 Multiparameter Photometer, HI83303 price
  • Description
  • Reviews (0)

Description

HI83303 Multiparameter Photometer

HI83303 Multiparameter Photometer

HI83303 Multiparameter Photometer

 

The HI83303 is a multiparameter Photometer with very small and modern size to measure water parameters.

HI83303 is proper device for aquaculture industry .

HI83300 measures 12 key water quality parameters.

HI83303 measure pH with a digital pH PROBE.

pH prob in HI83300 measure temperature too.

 

 

HI-83303 Aquaculture Photometer with pH meter

HI83303 works with optical system.

HI83303 measure Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.

HI83300 key characteristics been listed as below 

  • High Efficiency LED Light Source
  • High Quality Narrow Band Interference Filters
  • Reference Detector for a Stable Light Source
  • Large Cuvette Size
  • Focusing Lens for Greater Light Yield

 

Key features of HI83300 ARE AS BELOW:

  • Advanced optical system with brighter, long-lasting LED light source
  • Backlit 128 x 64 Pixel Graphic Liquid Crystal Display
  • Built-in Reaction Timer for Photometric Measurements
  • Absorbance mode – concentration versus absorbance
  • Units of Measurement plus chemical form displayed
  • Result conversion at the touch of a button
  • Cuvette cover
  • pH and temperature measurement with a single probe
  • Good Laboratory Practice (GLP) – track calibration information including date, time, buffers used, offset and slope for traceability
  • CAL Check alerts user to potential problems during the calibration process
  • Data Logging – Up to 1000 photometric and pH readings can be stored
  • Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs
  • Battery Status Indicator
  • Error Messages

To know HI83303 HANNA price or buy HI83303 Multiparameter Photometer, please contact Setare Arsh Aria company.

HI83303 Multiparameter Photometer Specifications:

Input Channels 1 pH electrode input and 5 photometer wavelengths
pH Electrode Digital pH electrode (not included)
Loggin g type Log on demand with user name and sample ID optional input
Logging Memory 1000 readings
Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity
GLP Calibration data for connected pH electrode
Display 128 x 64 pixel LCD with backlight
Battery Type/Life 3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement
Power supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
Environment 0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing
Dimensions 206 x 177 x 97mm (8.1 x 7.0 x 3.8″)
Weight 1.0 kg (2.2lbs)
Photometer/Colorimeter Light Source 5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters
Photometre/Colorimeter Light Detector Silicon Photodetector
Bandpass filter Bandwidth 8nm
Bandpass filter wavelength accruacy +-1nm
Cuvette Type Round, 24.6mm
Number of Methods 128 Max
Ordering Information HI-83303 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.
ALKALINITY
Alkalinity Range Freshwater: 0 to 500 mg/L (as CaCO3) Marine: 0 to 300 mg/L (as CaCO3)
Alkalinity Resolution 1 mg/L
Alkalinity Accuracy ±5 mg/L ±5% of reading
Alkalinity Method Colorimetric method
AMMONIA
Ammonia Range Low Range: 0.00 to 3.00 mg/L (as NH3-N) Medium Range: 0.00 to 10.00 mg/L (as NH3-N) High Range: 0.0 to 100.0 mg/L (as NH3-N)
Ammonia Resolution 0.01 mg/L; 0.1 mg/L
Ammonia Accuracy Low Range: ±0.04 mg/L ±4% of reading Medium Range: ±0.05 mg/L ±5% of reading High range: ±0.5 mg/L ±5% of reading at 25 °C
Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method
CALCIUM
Calcium Range Freshwater: 0 to 400 mg/L (as Ca2+) Marine: 200 to 600 mg/L (as Ca2+)
Calcium Resolution 1 mg/L
Calcium Accuracy Freshwater: ±10 mg/L ±5% of reading Marine: ±6% of reading
Calcium Method Freshwater: Adaptation of the Oxalate method Seawater: Adaptation of the Zincon method
CHLORINE
Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Free Chlorine Resolution 0.01 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading
Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Total Chlorine Resolution 0.01 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading
Chlorine Method Adaptation of the EPA 330.5 DPD method
COPPER
Copper Range Low Range: 0.000 to 1.500 mg/L (as Cu2+) High range: 0.00 to 5.00 mg/L (as Cu2+)
Copper Resolution 0.001 mg/L; 0.01 mg/L
Copper Accuracy Low Range: ±0.01 mg/L ±5% of reading High Range ±0.02 mg/L ±4% of reading
Copper Method Adaptation of the EPA bicinchoninate method
NITRATE
Nitrate Range 0.0 to 30.0 mg/L (as NO3— N)
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading
Nitrate Method Adaptation of the cadmium reduction method
NITRITE
Nitrite Range Freshwater Low Range: 0 to 600 μg/L (as NO2–N) High Range: 0 to 150 mg/L (as NO2-) Marine Ultra Low Range: 0 to 200 μg/L (as NO2–N)
Nitrite Resolution Freshwater: 1 μg/L; 1 mg/L Marine: 1 μg/L
Nitrite Accuracy Freshwater Low Range: ±20 μg/L ±4% of reading High Range: ±4 mg/L ±4% of reading Marine: ±10 μg/L ±4% of reading
Nitrite Method Adaptation of the EPA Diazotization method 354.1; HR Ferrous Sulphate
OXYGEN, DISSOLVED
Oxygen, Dissolved Range 0.0 to 10.0 mg/L (as O2)
Oxygen, Dissolved Resolution 0.1 mg/L
Oxygen, Dissolved Accuracy ±0.4 mg/L ±3% of reading
Oxygen, Dissolved Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
pH
pH Range Photometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH
pH Resolution Photometer: 0.1 pH pH electrode: 0.1 pH
pH Accuracy Photometer: ±0.1 pH pH electrode: ±0.01 pH
pH Calibration Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature Compensation Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used
pH CAL Check (electrode diagnostics) clean electrode and check buffer/check probe displayed during calibration
pH Method Photometer: phenol red
pH-mV Range ±1000 mV
pH-mV Resolution 0.1 mV
pH-mV Accuracy ±0.2 mV
PHOSPHATE
Phosphate Range Freshwater Low Range: 0.00 to 2.50 mg/L (as PO43-) High range: 0.0 to 30.0 mg/L (as PO43-) Seawater Ultra Low Range: 0 to 200 μg/L (as P)
Phosphate Resolution Freshwater: 0.01 mg/L; 0.1 mg/L Seawater: 1 μg/L
Phosphate Accuracy Freshwater Low Range: ±0.04 mg/L ±4% of reading High Range: ±1 mg/L ±4% of reading Seawater Ultra Low Range: ±5 μg/L ±5% of reading
Phosphate Method Freshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method
REAGENTS:
Alkalinity HI-775-26 for freshwater; HI-755-26 for saltwater
Ammonia HR & LR HR – HI-93733-01 (100 tests); HI-93733-03 (300 tests); MR – HI-93715-01 (100 tests); HI-93715-03 (300 tests); LR – HI-93700-01 (100 tests); HI-93700-03 (300 tests)
Calcium HI-937521-01 (50 tests); HI-937521-03 (150 tests)
Calcium – Marine HI-758-26
Chlorine – Free Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)
Chlorine Total HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)
Copper – HR, total & LR HR – HI-93702-01 (100 tests); HI-93702-03 (300 tests)
Total copper – HI-93702T – 01 (100 tests); HI-93702T-03 (300 tests)
LR – HI-95747-01 (100 tests); HI-95747-03 (300 tests)
Nitrate HI-93728-01 (100 tests); HI-93728-03 (300 tests)
Nitrite – HR & LR HR – HI-93708-01 (100 tests); HI-93708-03 (300 tests)
LR – HI-93707-01 (100 tests); HI-93707-03 (300 tests)
Nitrite – ULR Marine HI-764-25
Oxygen, Dissolved (DO) HI-93732-01 (100 tests); HI-93732-03 (300 tests)
pH HI-93710-01 (100 tests); HI-93710-03 (300 tests)
Phosphate – ULR Marine HI-736-25
Phosphate – HR & LR HR – HI-93717-01 (100 tests); HI-93717-03 (300 tests)
LR – HI-93713-01 (100 tests); HI-93713-03 (300 tests)

 

Reviews

There are no reviews yet.

Be the first to review “HI83303 Multiparameter Photometer” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

  • HI98129 COMBO Tester for pH/EC/TDS/C°

    HI98129 Multi parameter

  • HI98130 Multiparameter Tester

    HI98130 Multiparameter Tester

  • HI98131 Multiparameter Tester

    HI98131 Multiparameter Tester

  • HI83300 Multiparameter Photometer

    HI83300 Multiparameter Photometer

Contact Us

  • Unit 26 – No 253 – Kolahdooz Avenue – Tehran – Iran
  • Tel : 0982122799056 , 65
  • Fax : 0982122799073
  • Email: info@sa-aria.com

direction:ltr

Related Links

  • www.hannainst.com
  • www.testometric.co.uk
  • www.xrite.com
  • www.moderner.com
Setare Arsh Aria is a consulting and trading company which would like to improve the quality level of our country’s industries in the fields of laboratory, educational and QC instruments. We believe that our most important asset is the team of people we have at Setare Arsh Aria and the skills they bring to the company.
Setare Arsh Aria is the official agent of many best-known companies. We are trying our best to develop our customers’ knowledge and skills by distributing those companies’ technical knowledge and services.
We would be honored to provide satisfactory and support to our costomers by offering our products with the best quality and reasonable price.
© Copyright - setare arsh aria
HI83306 Multiparameter Photometer HI83306 Multiparameter Photometer HI83399 multiparameter with COD photometer HI83399 multiparameter with COD photometer
Scroll to top