HI932C2 Automatic Titrator
HI932C2 Automatic Titrator Potentiometric Titration Systems (pH/mV/ISE)
Hanna Instruments HI932 Automatic Titrator is the perfect answer to your specific titration needs. This device is fully adjustable with accurate results and is used for various titrations including acid and base, ORP, selective ions and photometry.
All you need to start using HI932 is a suitable electrode and titrant.
It is small and compact so that it does not take up much space in the laboratory.
It has a very accurate 1 to 40,000 injection pump to help you get very accurate results by getting an accurate end point.
The HI932 automatic titrator can be ordered with one or two analog boards for successive titration.
The HI932 automatic titrator has the ability to connect to the HI921 autosampler and it is possible to automatically test 18 samples.
The HI-932 automatic titrator is designed to perform a wide variety of potentiometric titrations with high accuracy and flexibility, allowing the user to obtain both accurate results and high-speed analysis.
The titrator can perform fixed endpoint or equivalence point titrations and direct measurements by measuring the pH/mV and temperature of the sample.
Reports and materials can be transferred to a PC via a USB interface, saved to a USB storage device or printed directly from the titrator. An external keyboard can also be attached for added convenience.
The HI-921 & HI-922 Autosamplers can be connected for sample automation.
Dynamic titrant dosing
The dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.
Equivalence endpoint detection
Equivalence endpoint detection is critical in applications where fixed endpoints are not specified in standard methods. This endpoint indicates where the mV response from the titration is greatest with respect to the volume of titrant dosed.
Signal stability timing
The signal stability feature monitors when the mV response of the titration reaction stabilises before providing the next titrant dose. This ensures reliable measurement values throughout the length of a titration.
Multiple equivalence point detection
HI932C2 Automatic Titrator can detect multiple equivalence points during one titration as specified and required in certain standard methods and applications.
Method sequencing
HI932C2 Automatic Titrator offers users the option of linking two methods. This allows for two analyses to be run on the same sample including direct measurements, single endpoint titrations, multiple equivalence point titrations, and back titrations.
Multiple titration types
Paired with the right electrode from our sensor line, our potentiometric titrators can perform acid/base, redox (ORP), complexometric, precipitation, non-aqueous, argentometric, and ion selective titrations, as well as back titrations and titre determinations.
Direct measurement functionality
HI932C2 Automatic Titrator performs as a high accuracy pH, ORP, and ion selective meter that can link, log, and report direct measurements. Users can easily track and manage data without the hassle of manual record keeping.
Burettes and dosing system
Exchangeable burette system
With Hanna’s Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents preventing cross-contamination and saving time.
Multiple burette sizes
HI932C2 Automatic Titrator comes supplied with a 25mL burette but may be equipped with a 5mL, 10mL or 50mL burette. Each burette is constructed with a ground glass syringe and chemically resistant PTFE plunger.
Precision dosing pump
Our unmatched 40,000 step piston driven pump is capable of dosing extremely small and highly accurate volumes of titrant or reagent.
Automatic reagent addition
A peristaltic pump or a second burette may be programmed to volumetrically dispense reagent prior to titration or direct measurement. This helps achieve consistent and accurate results and prevents operator errors such as incorrect volumes or forgetting reagent addition.
Methods of analysis
Customizable methods
These titrators can store up to 100 user-defined or standard titration and direct measurement methods. Each method may be modified and optimized for performance based on application and user requirements.
Titration method support
Onsite installation, training, and customisation is available from one of our product specialists. Hanna offers continued support for any questions you might have along the way.
Market specific methods packs
Hanna offers titration method packages for various markets including food, beverage, dairy, wine, and more.
Data Storage
Up to 100 titration and pH/mV/ISE reports. Transfer data via USB
.Flexible GLP management All necessary GLP (Good Laboratory Practice) information can be recorded with each sample.
Connectivity and functionality
Multifunctional
The titrators also function as a titrator, pH meter, mV/ORP meter, and ISE meter. Valuable laboratory bench space is saved, and multiple analyses can be performed on one sample.
Multiple Connections
HI932C2 Automatic Titrator offers support for two analog boards, allowing up to two electrodes, two burettes, and two stirrers to be connected to one unit simultaneously.
Autosampler connectivity
HI932C2 Automatic Titrator works seamlessly with the HI-922 autosampler featuring 16 or 18 sample tray options, automatic tray identification, and automatic beaker detection. Up to three peristaltic pumps for reagent addition and removal can be connected and real-time analysis and sequencing progress is visible on the HI-932 display as well as indicated by the LED lights of the autosampler.
Interface and display
Interactive colour display
A large, colour LCD screen clearly shows the chosen titration method along with results, units, titration volume, temperature, and mV or pH values.
Detailed titration graphs
A real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.
Fully customizable titration methods
Titration graphs
Titration graphs can be viewed on-screen or saved as images and transferred along with titration report.
Customizable reports
Data to be stored in titration reports is fully customizable.
Specifications
HI932C2 Automatic Titrator Specifications:
pH | ||
Range | -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH | |
Resolution | 0.1; 0.01; 0.001 pH | |
Accuracy (@25°C) | ±0.001 pH | |
pH Calibration | up to five-point calibration, eight standard buffers and five custom buffers | |
mV | ||
Range | -2000.0 to 2000.0 mV | |
Resolution | 0.1 mV | |
Accuracy (@25°C) | ±0.1 mV | |
mV Calibration | single point offset | |
ISE | ||
Range | 1•10-6 to 9.99•1010 | |
Resolution | 1; 0.1; 0.01 | |
Accuracy (@25°C) | ±0.5% monovalent; ±1% divalent | |
ISE Calibration | Up to five-point calibration, seven standard solutions and five user-defined standards | |
Temperature | ||
Range | -5.0 to 105.0°C | |
Resolution | 0.1°C | |
Accuracy (@25°C) | ±0.1°C excluding probe error | |
Additional Specifications | ||
Analog Board(s) capability | 2 | |
Dosing Pump Capability | 2 | |
Burette included | 1 (25mL) | |
Burette Size Capability | 5, 10, 25 and 50 mL | |
Burette Resolution | 1/40000 | |
Display Resolution | 0.001 mL | |
Dosing Accuracy | ±0.1% of full burette volume | |
Display | 14.9cm (5.7”) 320 x 240 pixel) backlit colour LCD | |
GLP Conformity | Instrumentation data storage and printing capabilities | |
Linked Methods | Yes | |
Back Titrations | Yes | |
HI-921 & HI-922 autosampler compatible | Yes | |
Power | 100-240 VAC | |
Ordering information | HI-932C2-02 includes titrator with two analog boards* All models also include: overhead propeller stirrer with stand, 25ml glass burette, dosing pump, temperature sensor, USB cable, USB Flash drive and PC Software. |
|
Additional Extras | ||
HI-930101 | Dosing pump with peristaltic pump | |
HI-930100 | Dosing pump | |
HI-930150 | 50 mL burette assembly (includes syringe, aspiration, and dispensing tubes) | |
HI-930125 | 25 mL burette assembly (includes syringe, aspiration, and dispensing tubes) | |
HI-930110 | 10 mL burette assembly (includes syringe, aspiration, and dispensing tubes) | |
HI-930105 | 5 mL burette assembly (includes syringe, aspiration, and dispensing tubes) | |
*Each Analog board provides 1 BNC (pH, mV, ISE) input, 1 temperature input, 1 stirrer input. |