Description
HI2002 edge™ – pH/ORP meter with CAL Check
HI2002 is a professional bench top pH meter.
Wall Mount HI2002 edge.
Cradle and Electrode Holder HI2002 edge.
Two USB Ports HI2002 edge.
Data Logging HI2002 edge.
To know HI2002 HANNA price or buy HI202 edge ,please contact Setare Arsh Aria Company.
HI2002 edge™ – pH/ORP meter with CAL Check pH Specifications:
pH Range | -2.000 to 16.000 pH (Standard Mode), -2.00 to 16.00 pH (Basic Mode) |
---|---|
pH Resolution | 0.001 pH, 0.01 pH |
pH Accuracy (@25ºC/77ºF) | ±0.01 pH, ±0.002 pH |
pH Calibration | 5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01 |
pH Temperature Compensation | ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F* |
mV Range | ±1000.0 mV; ±2000.0 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.2 mV (±999.9 mV); ±1 mV (±2000 mV) |
Relative mV Calibration | Single point calibration |
HI2002 edge™ – pH/ORP meter with CAL Check Temperature Specifications:
Temperature Range | -20.0 to 120.0 ºC, -4.0 to 248.0 °F |
---|---|
Temperature Resolution | 0.1 °C, 0.1 °F |
Temperature Accuracy | ±0.5 °C, ±0.9 °F |
°C/°F | Yes |
HI2002 edge™ – pH/ORP meter with CAL Check Additional Specifications
pH Electrode Diagnostics | Glass and reference junction diagnostics ( HI 11311 & HI 12301 only), out of calibration range , probe condition, response time |
---|---|
GLP | Yes |
Logging | up to 1000*** records organized in: Manual log-on-demand (Max. 200 logs), Manual log-on-stability (Max. 200 logs), Interval logging *** (Max. 600 samples; 100 lots) |
Connectivity | 1 micro USB port for charging and PC connectivity, 1 USB port for storage |
Environment | 0 to 50°C (32 to 122°F), RH max 95% non-condensing |
Battery Type/Life | Built-in rechargeable battery with up to 8 hours of continuous use |
Power Supply | 5 VDC adapter (included) |
Dimensions | 202 x 140 x 12.7mm (8” x 5.5” x 0.5”) |
Weight | 250 g (8.82 oz) |
Ordering Information | edge® HI2002 includes benchtop docking station with electrode holder, wall mount cradle, USB cable, HI11310 glass body refillable pH electrode with temperature sensor, 2 sachets each of pH 4, 7, 10, cleaning solution, 5 VDC power adapter and instruction manual. |
Notes | * temperature limits will be reduced to actual probe/sensor limits *** For standard mode only (logging) † pH 3.00 is only visible when using specific pH electrodes and will replace pH 4.01 buffer |
Reviews
There are no reviews yet.