Description
HI2202 pH Meter and HALO
HI2202 is a benchtop pH meter that ,we can use it in form of portable .
HI2202 has a Bluetooth Smart Technology.
HI2202 has Built-In Temperature Sensor.
The probe has lass body . it is resistant to many chemicals and easy to clean.
Design of junction is double , this design is suitable for a variety of solutions that can contain substances such as heavy metals or Tris buffer that will cause the silver chloride (AgCl) found in a single junction probe to precipitate and clog the junction.
To know HI2202 price or buy HI2202 HALO Hanna ,please contact Setare Arsh Aria Company.
pH Specifications (HI11102)
pH Range pH Resolution pH Accuracy (@25ºC/77ºF)pH Calibration pH Temperature Compensation
-2.000 to 16.000 pH (Standard Mode), -2.00 to 16.00 pH (Basic Mode), ±1000 mV |
0.001 pH, 0.01 pH, 0.1 mV |
±0.2 mV, ±0.01 pH, ±0.002 pH |
5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01 |
ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F* |
*For other electrodes, please visit the accessories section to look at the individual specification.
HI2202 – pH Meter and HALO™ pH Probe with Bluetooth® Smart Technology – No Cable Temperature Specifications
Temperature Range
-20.0 to 120.0 ºC, -4.0 to 248.0 °F |
0.1 °C, 0.1 °F |
±0.5 °C, ±0.9 °F |
Yes |
HI2202 – pH Meter and HALO™ pH Probe with Bluetooth® Smart Technology – No Cable Additional Specifications
GLP Logging
Yes |
stores up to 1000 records: 200 records (log-on-demand and stability logging) |
1 micro USB port for charging and PC connectivity, 1 USB port for storage |
0 to 50°C (32 to 122°F), RH max 95% non-condensing |
5 VDC adapter (included) |
202 x 140 x 12 mm (7.9” x 5.5” x .05”) |
250 grams (8.82 oz.) |
HI2202 edge® blu includes benchtop docking station with electrode holder, wall mount cradle, USB cable, HI11102 glass body, gel filled pH electrode with temperature sensor, pH 4 buffer solution sachets, pH 7 buffer solution sachets, pH 10 buffer solution sachets, electrode cleaning solution sachets, 5 VDC power adapter, instruction manual and instrument quality certificate. |
* temperature limits will be reduced to actual probe/sensor limits ** with temperature compensation function disabled † pH 3.00 is only visible when using specific pH electrodes and will replace pH 4.01 buffer |
Electrode Specifications (For HI11102)
Reference Junction
double, Ag/AgCl |
ceramic |
gel |
spheric |
Bluetooth Smart (Bluetooth 4.0), 10 m (33′) range |
-5 to 80°C (23 to 176°F) |
integrated |
glass |
*For other electrodes, please visit the accessories section to look at the individual specification.
Hanna Lab App Specifications
Range Resolution Accuracy (@25ºC/77ºF)Calibration
-2.000 to 16.000 pH / ±800 mV / -20.0 to 120.0 ºC *(will be reduced to actual probe/sensor limits) |
0.1, 0.01, 0.001 pH / 1, 0.1 mV |
±0.005 pH / ±0.3 mV |
Up to five points with seven standard buffers |
1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH |
Automatic from -5.0 to 100.0 ºC / 23.0 to 212.0 ºF *(will be reduced to actual probe/sensor limits) |