Give us a call now: 22799067
  • 0Shopping Cart
setare arsh aria
  • Home
  • Chemical Test
    • pH / ORP
      • Tester pH / ORP
      • Portable pH / ORP
      • BenchTop pH / ORP
      • Online pH / ORP
    • EC / TDS
      • Tester EC / TDS
      • Portable EC / TDS
      • BenchTop EC / TDS
      • Online EC / TDS
    • DO (Dissolved Oxygen)
      • Portable DO
      • BenchTop DO
      • Online DO
    • Multiparameter
      • Tester Mutiparameter
      • Portable Multiparameter
      • BenchTop Multiparameter
      • Online Multiparameter
    • Turbidity
      • Portable Turbidity
      • BenchTop Turbidity
    • Photometer / Spectrophotometer
      • Checker
      • Portable Photometer
      • Bench Top Photometer
      • Spectrophotometer
      • COD
    • Titrator / Karl Fisher
      • Titrator
      • Karl Fisher
    • Refractometer
    • Electrodes
      • pH Electrodes
      • ORP Electrodes
      • EC/TDS Electrodes
      • DO Electrodes
      • ISE Electrodes
  • Agencies
  • Blog
    • Articles
    • Seminars
    • Exhibitions
  • Services
    • Guarantee & Warranty
    • Training & Installment
  • About
  • Contact
  • FA
  • Menu
HI801 Iris Spectrophotometer
HI801 Iris Spectrophotometer

HI801 Iris Spectrophotometer

HI801 Iris Spectrophotometer

 

HI801 Iris Spectrophotometer

HI801 Iris Spectrophotometer

 

The HI-801 iris is a sleek and intuitive spectrophotometer that allows for measurement of all wavelengths of visible light.

Customise your methods, take a wide range of measurements, and feel confident in your testing accuracy with iris.

  • iris features precise wavelength selection between 340 nm to 900 nm for complete method compliance and accuracy that is necessary in industries like professional laboratories, water treatment facilities, wineries, and more.
Categories: Photometer / Spectrophotometer, Bench-top Instruments, Products Tag: HI801 Iris Spectrophotometer
  • Description
  • Reviews (0)

Description

HI801 Iris Spectrophotometer

HI801 Iris Spectrophotometer

HI801 Iris Spectrophotometer

 

THE UNIQUE HANNA SPECTROPHOTOMER

HI801 is a Visible Spectrophotometer . HI801 canmeasures all visible wavelengths those are in visible light.

with customizing measuring method can achieve the high accuracy in HI801.

 

HI801 can measure accurate selection of wavelengths between 340 nm and 900 nm in accordance .

 

 

  • user can use multiple cuvette shapes and sizes,  calibration curves, and methods as his favorite and customize it.

hi801 dispay is 6 inch displayand extermly large and to see and read. The high contrast makes every character on the display stand out – even during outdoor use.

hi801 cuvette has an universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed between round, square & vial.

 

summery of HI801 Charactristic:

 

  • Pre-programmed methods with the option to expand
  • Worry free replacements
  • Designed for dynamic environments
  • Quality data without the hassle
  • Sort and share your data

 

 

 

Menu navigation that makes sense

Quickly navigate between screens with custom keys, and access your favourite methods directly from the home screen with our “favourite methods” feature.

All of your important information is easily visible

HI801  has a wide LCD with 6” size . its wide display make users to read the informations is from the display screen.

Zero resistance with a capacitive touch pad

the bottoms of HI801 are so sensitive and they can sense even pushing by gloves .

user have to keep the bottons clean.

Change sample size easily

HI801  has universal cuvvette holder and it can help user to change cuvette size if needed.

Specifications

To know HI801 HANNA price or buy HI801 Iris Spectrophotometer , please contact Setare Arsh Aria company.

HI801 Iris Spectrophotometer Specifications

Wavelength Range 340 to 900 nm
Wavelength Resolution 1 nm
Wavelength Accuracy ±1.5 nm
Measurement Modes Transmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg/L, ppt, °f, °e, ppb, meq/L, μg/L, PCU, Pfund, pH, dKH, °dH, meq/kg or no measurement unit)
Wavelength Selection automatic, based on the selected method (editable for user methods only)
Light Source tungsten halogen lamp
Optical System split beam sample and reference light detectors
Wavelength Calibration Internal, automatic at power-on, visual feedback
Stray Light <0.1 % T at 340 nm with NaNO2
Spectral bandwidth 5 nm (full width at half maximum)
Sample Cell 16 mm round, 22 mm round, 13 mm vial, 10 mm square, 50 mm rectangular (with automatic detection)
Programs (Factory/User) Up to 150 factory (85 pre-loaded); up to 100 user developed
Data Points Stored Up to 9999 measured values
Export Capability .csv file format, .pdf file format
Connectivity (1) USB – A (mass storage host); (1) USB – B (mass storage device)
Battery Type / Life 3000 measurements or 8 hours
Power Supply 15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery
Environment 0 to 50 °C (32 to 122 °F); 0 to 95% RH
Dimensions 155 x 205 x 322 mm
Weight 3 kg (6.6 lbs)
Ordering Information HI-801 is supplied with 22 mm sample cuvette and cap (4), 10 mm square, 13 mm round and 16 mm round cuvette adapters, cloth for wiping cuvettes, scissors, USB cable, lithium ion rechargeable battery, 115VAC to 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate.
ABSORBANCE
 Range 0.000 to 3.000 Abs
 Resolution 0.001 Abs
 Accuracy (@25°C) 5 mAbs at 0.000-0.500 Abs 1% at 0.500-3.000 Abs
ALKALINITY
 Range 0 to 500 mg/L (as CaCO3 )
 Resolution 1 mg/L
 Accuracy (@25°C) ±5 mg/L ±5% of reading
 Method Colorimetric Method
 Wavelength 610 nm
 Reagent Code HI-775-26
ALKALINITY, MARINE
 Range 0 to 300 mg/L (as CaCO3 )
 Resolution 1 mg/L
 Accuracy (@25°C) ±5 mg/L ±5% of reading
 Method Colorimetric Method
 Wavelength 610 nm
 Reagent Code HI-755-26
ALUMINIUM
 Range 0.00 to 1.00 mg/L (as Al3+)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.04 mg/L ±4% of reading
 Method Adaptation of the aluminon method
 Wavelength 525 nm
 Reagent Code HI-93712-01
AMMONIA, LOW RANGE
 Range 0.00 to 3.00 mg/L (as NH3 -N)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.04 mg/L ±4% of reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method.
 Wavelength 420 nm
 Reagent Code HI-93700-01
AMMONIA, MEDIUM RANGE
 Range 0.00 to10.00 mg/L (as NH3 -N)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.05 mg/L ±5% of reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method
 Wavelength 420 nm
 Reagent Code HI-93715-01
AMMONIA, HIGH RANGE
 Range 0.0 to 100.0 mg/L (as NH3 -N)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.5 mg/L ±5% of reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method
 Wavelength 420 nm
 Reagent Code HI-93733-01
BROMINE
 Range 0.00 to 8.00 mg/L (as Br2 )
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.08 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
 Wavelength 525 nm
 Reagent Code HI-93716-01
CALCIUM
 Range 0 to 400 mg/L (as Ca2+)
 Resolution 1 mg/L
 Accuracy (@25°C) ±10 mg/L ±5% of reading
 Method Adaptation of the Oxalate method
 Wavelength 466nm
 Reagent Code HI-937521-01
CALCIUM, MARINE
 Range 200 to 600 mg/L (as Ca2+)
 Resolution 1 mg/L
 Accuracy (@25°C) ±6% of reading
 Method Adaptation of the Zincon method
 Wavelength 610 nm
 Reagent Code HI-758-26
CHEMICAL OXYGEN DEMAND
LOW RANGE
 Range 0 to 150 mg/L (as O2 )
 Resolution 1 mg/L
 Accuracy (@25°C) ±5 mg/L or ±4% of reading
 Method Adaptation of the USEPA 410.4
 Wavelength 420 nm
 Reagent Code HI-93754A-25
CHEMICAL OXYGEN DEMAND
MEDIUM RANGE
 Range 0 to 1500 mg/L (as O2)
 Resolution 1 mg/L
 Accuracy (@25°C) ±15 mg/L or ±4% of reading
 Method Adaptation of the USEPA 410.4
 Wavelength 610 nm
 Reagent Code HI-93754B-25
CHEMICAL OXYGEN DEMAND
HIGH RANGE
 Range 0 to 15000 mg/L (as O2 )
 Resolution 1 mg/L
 Accuracy (@25°C) ±150 mg/L or ±2% of reading
 Method Adaptation of the USEPA 410.4
 Wavelength 610 nm
 Reagent Code HI-93754C-25
CHLORIDE
 Range 0.0 to 20.0 mg/L (as Cl)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.5 mg/L ±6% of reading
 Method Adaptation of the mercury(II) thiocyanate method
 Wavelength 466 nm
 Reagent Code HI-93753-01
CHLORINE DIOXIDE
 Range 0.00 to 2.00 mg/L (as ClO2 )
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.10 mg/L ±5% of reading
 Method Adaptation of the Chlorophenol Red method
 Wavelength 575 nm
 Reagent Code HI-93738-01
CHLORINE, FREE ULTRA LOW RANGE
 Range 0.000 to 0.500 mg/L (as Cl2 )
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.020 mg/L ±3% of reading
 Method Adaptation of the Standard Method 4500-Cl G
 Wavelength 525 nm
 Reagent Code HI-95762-01
CHLORINE, FREE LOW RANGE
 Range 0.00 to 5.00 mg/L (as Cl2)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the EPA DPD method 330.5
 Wavelength 525 nm
 Reagent Code HI-93701-01
CHLORINE, FREE HIGH RANGE
 Range 0.00 to 10.00 mg/L (as Cl2)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the EPA DPD method 330.5
 Wavelength 525 nm
 Reagent Code HI-93734-01
CHLORINE, TOTAL ULTRA LOW RANGE
 Range 0.000 to 0.500 mg/L (as Cl2 )
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.020 mg/L ±3% of reading
 Method Adaptation of the EPA recommended Method 330.5
 Wavelength 525 nm
 Reagent Code HI-95761-01
CHLORINE, TOTAL LOW RANGE
 Range 0.00 to 5.00 mg/L (as Cl2)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the EPA DPD method 330.5
 Wavelength 525 nm
 Reagent Code HI-93711-01
CHLORINE, TOTAL HIGH RANGE
 Range 0.00 to 10.00 mg/L (as Cl2)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the EPA DPD method 330.5
 Wavelength 525 nm
 Reagent Code HI-93734-01
CHLORINE, TOTAL ULTRA HIGH RANGE
 Range 0 to 500 mg/L (as Cl2)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl
 Wavelength 525 nm
 Reagent Code HI-95771-01
CHROMIUM (VI), LOW RANGE
 Range 0 to 300 µg/L (as Cr(VI))
 Resolution 1 µg/L
 Accuracy (@25°C) ±10 µg/L ±4% of reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide method
 Wavelength 525 nm
 Reagent Code HI-93749-01
CHROMIUM (VI), HIGH RANGE
 Range 0 to 1000 µg/L (as Cr(VI))
 Resolution 1 µg/L
 Accuracy (@25°C) ±5 µg/L ±4% of reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide method
 Wavelength 525 nm
 Reagent Code HI-93723-01
COLOUR OF WATER
 Range 0 to 500 PCU (Platinum Cobalt Units)
 Resolution 1 PCU
 Accuracy (@25°C) ±10 PCU ±5% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method
 Wavelength 420 nm
 Reagent Code
COPPER, LOW RANGE
 Range 0.000 to 1.500 mg/L (as Cu)
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.010 mg/L ±5% of reading
 Method Adaptation of the EPA method
 Wavelength 575 nm
 Reagent Code HI-95747-01
COPPER, HIGH RANGE
 Range 0.00 to 5.00 mg/L (as Cu)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.02 mg/L ±4% of reading
 Method Adaptation of the EPA method
 Wavelength 575 nm
 Reagent Code HI-93702-01
CYANIDE
 Range 0.000 to 0.200 mg/L (as CN-)
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.005 mg/L ±3% of reading
 Method Pyridine-Pyrazalone
 Wavelength 610 nm
 Reagent Code HI-93714-01
CYANURIC ACID
 Range 0 to 100 mg/L (as CYA)
 Resolution 1 mg/L
 Accuracy (@25°C) ±1 mg/L ±15% of reading
 Method Adaptation of the turbidimetric method
 Wavelength 525 nm
 Reagent Code HI-93722-01
FLUORIDE, LOW RANGE
 Range 0.00 to 2.00 mg/L (as F)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
 Wavelength 575 nm
 Reagent Code HI-93729-01
FLUORIDE, HIGH RANGE
 Range 0.0 to 20.0 mg/L (as F)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.5 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
 Wavelength 575 nm
 Reagent Code HI-93739-01
HARDNESS, CALCIUM
 Range 0.00 to 2.70 mg/L (as CaCO3)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.11 mg/L ±5% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method
 Wavelength 525 nm
 Reagent Code HI-93720-01
HARDNESS, MAGNESIUM
 Range 0.00 to 2.00 mg/L (as CaCO3)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.11 mg/L ±5% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method
 Wavelength 525 nm
 Reagent Code HI-93719-01
HARDNESS, TOTAL LOW RANGE
 Range 0.00 to 250 mg/L (as CaCO3)
 Resolution 1 mg/L
 Accuracy (@25°C) ±5 mg/L ±4% of reading
 Method Adaptation of the EPA recommended method 130.1
 Wavelength 466 nm
 Reagent Code HI-93735-00
HARDNESS, TOTAL MEDIUM RANGE
 Range 200 to 500 mg/L (as CaCO3)
 Resolution 1 mg/L
 Accuracy (@25°C) ±7 mg/L ±3% of reading
 Method Adaptation of the EPA recommended method 130.1
 Wavelength 466 nm
 Reagent Code HI-93735-01
HARDNESS, TOTAL HIGH RANGE
 Range 400 to 750 mg/L (as CaCO3)
 Resolution 1 mg/L
 Accuracy (@25°C) ±10 mg/L ±2% of reading
 Method Adaptation of the EPA recommended method 130.1
 Wavelength 466 nm
 Reagent Code HI-93735-02
HYDRAZINE
 Range 0 to 400 µg/L (as N2H4 )
 Resolution 1 µg/L
 Accuracy (@25°C) ±4% of full scale reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminobenzaldehyde method
 Wavelength 466 nm
 Reagent Code HI-93704-01
IODINE
 Range 0.0 to 12.5 mg/L (as I2)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.1 mg/L ±5% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
 Wavelength 525 nm
 Reagent Code HI-93718-01
IRON, LOW RANGE
 Range 0.000 to 1.600 mg/L (as Fe)
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.010 mg/L ±8% of reading
 Method Adaptation of the TPTZ Method
 Wavelength 575 nm
 Reagent Code HI-93746-01
IRON, HIGH RANGE
 Range 0.00 to 5.00 mg/L (as Fe)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.04 mg/L ±2% of reading
 Method Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters
 Wavelength 525 nm
 Reagent Code HI-93721-01
MAGNESIUM
 Range 0 to 150 mg/L (as Mg2+)
 Resolution 1 mg/L
 Accuracy (@25°C) ±5 mg/L ±3% of reading
 Method Adaptation of the Calmagite method
 Wavelength 466 nm
 Reagent Code HI-937520-01
MANGANESE, LOW RANGE
 Range 0 to 300 µg/L (as Mn)
 Resolution 1 µg/L
 Accuracy (@25°C) ±10 µg/L ±3% of reading
 Method Adaptation of the PAN Method
 Wavelength 575 nm
 Reagent Code HI-93748-01
MANGANESE, HIGH RANGE
 Range 0.0 to 20.0 mg/L (as Mn)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.2 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method
 Wavelength 525 nm
 Reagent Code HI-93709-01
MAPLE SYRUP
 Range 0.00 to 100.00 %T
 Resolution 0.01 %T
 Accuracy (@25°C) ±3% of reading
 Method Direct measure
 Wavelength 560 nm
 Reagent Code HI-93703-57
MOLYBDENUM
 Range 0.0 to 40.0 mg/L (as Mo6+)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.3 mg/L ±5% of reading
 Method Adaptation of the mercaptoacetic acid method
 Wavelength 420 nm
 Reagent Code HI-93730-01
NICKEL, LOW RANGE
 Range 0.000 to 1.000 mg/L (as Ni)
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.010 mg/L ±7% of reading
 Method Adaptation of the PAN method
 Wavelength 575 nm
 Reagent Code HI-93740-01
NICKEL, HIGH RANGE
 Range 0.00 to 7.00 g/L (as Ni)
 Resolution 0.01 g/L
 Accuracy (@25°C) ±0.07g/L ±4% of reading
 Method Adaptation of the photometric method
 Wavelength 575 nm
 Reagent Code HI-93726-01
NITRATE
 Range 0.0 to 30.0 mg/L (as NO3 – N)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.5 mg/L ±10% of reading
 Method Adaptation of the cadmium reduction method
 Wavelength 525 nm
 Reagent Code HI-93728-01
NITRATE, CHROMOTROPIC ACID
 Range 0.0 to 30.0 mg/L (as NO3 – N)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±1.0 mg/L ±3% of reading
 Method Chromotropic acid method
 Wavelength 410 nm
 Reagent Code HI-93766-50
NITRITE MARINE
ULTRA LOW RANGE
 Range 0 to 200 µg/L (as N02-N)
 Resolution 1 µg/L
 Accuracy (@25°C) ±10 µg/L ±4% of reading
 Method Adaptation of the EPA Diazotization method 354.1
 Wavelength 466nm
 Reagent Code HI-764-25
NITRITE, LOW RANGE
 Range 0 to 600 µg/L (as N02-N)
 Resolution 1 µg/L
 Accuracy (@25°C) ±20 µg/L ±4% of reading
 Method Adaptation of the EPA Diazotization method 354.1
 Wavelength 466nm
 Reagent Code HI-93707-01
NITRITE, HIGH RANGE
 Range 0 to 150 mg/L (as NO2-)
 Resolution 1 mg/L
 Accuracy (@25°C) ±4 mg/L ±4% of reading
 Method Adaptation of the Ferrous Sulphate method
 Wavelength 575 nm
 Reagent Code HI-93708-01
NITROGEN, TOTAL LOW RANGE
 Range 0.0 to 25.0 mg/L (as N)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±1.0 mg/L or ±5% of reading
 Method Chromotropic acid method
 Wavelength 420 nm
 Reagent Code HI-93767A-50
NITROGEN, TOTAL HIGH RANGE
 Range 10 TO 150 mg/L (as N)
 Resolution 1 mg/L
 Accuracy (@25°C) ±3 mg/L or ±4% of reading
 Method Chromotropic acid method
 Wavelength 420 nm
 Reagent Code HI-93767b-50
OXYGEN, DISSOLVED
 Range 0.0 to 10.0 mg/L (as O2)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.4 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
 Wavelength 420 nm
 Reagent Code HI-93732-01
OXYGEN SCAVENGERS
(CARBOHYDRAZIDE)
 Range 0.00 to 1.50 mg/L (as Carbohydrazide)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.02 mg/L ±3% of reading
 Method Adaptation of the iron reduction method
 Wavelength 575 nm
 Reagent Code HI-96773-01
OXYGEN SCAVENGERS
(DIETHYLHYDROXYLAMINE)(DEHA)
 Range 0 to 1000 µg/L (as DEHA)
 Resolution 1 µg/L
 Accuracy (@25°C) ±5 µg/L ±5% of reading
 Method Adaptation of the iron reduction method
 Wavelength 575 nm
 Reagent Code HI-96773-01
OXYGEN SCAVENGERS
(HYDROQUINONE)
 Range 0.00 to 2.50 mg/L (as Hydroquinone)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.04 mg/L ±3% of reading
 Method Adaptation of the iron reduction method
 Wavelength 575 nm
 Reagent Code HI-96773-01
OXYGEN SCAVENGERS
(ISO-ASCORBIC ACID)
 Range 0.00 to 4.50 mg/L (as Iso-ascorbic acid)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the iron reduction method
 Wavelength 575 nm
 Reagent Code HI-96773-01
OZONE
 Range 0.00 to 2.00 mg/L (as O3 )
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.02 mg/L ±3% of reading
 Method Colorimetric DPD Method
 Wavelength 525 nm
 Reagent Code HI-93757-01
pH
 Range 6.5 to 8.5 pH
 Resolution 0.1pH
 Accuracy (@25°C) ±0.1 pH
 Method Adaptation of the Phenol Red method
 Wavelength 525 nm
 Reagent Code HI-93710-01
PHOSPHORUS
MARINE ULTRA LOW RANGE
 Range 0 to 200 µg/L (as P)
 Resolution 1 µg/L
 Accuracy (@25°C) ±5 µg/L ±5% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Ascorbic Acid method
 Wavelength 610 nm
 Reagent Code HI-736-25
PHOSPHATE, LOW RANGE
 Range 0.00 to 2.50 mg/L (as PO4 3-)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.04 mg/L ±4% of reading
 Method Adaptation of the Ascorbic Acid method
 Wavelength 610 nm
 Reagent Code HI-93713-01
PHOSPHATE, HIGH RANGE
 Range 0.0 to 30.0 mg/L (as PO4 3-)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±1.0 mg/L ±4% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method
 Wavelength 525 nm
 Reagent Code HI-93717-01
PHOSPHORUS
REACTIVE LOW RANGE
 Range 0.00 to 1.60 mg/L (as P)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.05 mg/L or ±4% of reading
 Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method
 Wavelength 610 nm
 Reagent Code HI-93758A-50
PHOSPHORUS
REACTIVE HIGH RANGE
 Range 0.0 to 32.6 mg/L (as P)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.5 mg/L or ±4% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method
 Wavelength 420 nm
 Reagent Code HI-93763A-50
PHOSPHORUS, ACID HYDROLYZABLE
 Range 0.00 to 1.60 mg/L (as P)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.05 mg/L or ±5% of reading
 Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method
 Wavelength 610 nm
 Reagent Code HI-93758B-50
PHOSPHORUS
TOTAL LOW RANGE
 Range 0.00 to 1.15 mg/L (as P)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.05 mg/L or ±6% of reading
 Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method
 Wavelength 610 nm
 Reagent Code HI-93758c-50
PHOSPHORUS
TOTAL HIGH RANGE
 Range 0.00 to 32.6 mg/L (as P)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.05 mg/L or ±5% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method
 Wavelength 420 nm
 Reagent Code HI-93763B-50
POTASSIUM, LOW RANGE
 Range 0.0 to 20.0 mg/L (as K)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±2 mg/L ±7% of reading
 Method Adaptation of the Turbidimetric Tetraphenylborate method
 Wavelength 466 nm
 Reagent Code HI-93750-01
POTASSIUM, MEDIUM RANGE
 Range 10 to 100 mg/L (as K)
 Resolution 1 mg/L
 Accuracy (@25°C) ±10 mg/L ±7% of reading
 Method Adaptation of the Turbidimetric Tetraphenylborate method
 Wavelength 466 nm
 Reagent Code HI-93750-01
POTASSIUM, HIGH RANGE
 Range 20 to 200 mg/L (as K)
 Resolution 1 mg/L
 Accuracy (@25°C) ±20 mg/L ±7% of reading
 Method Adaptation of the Turbidimetric Tetraphenylborate method
 Wavelength 466 nm
 Reagent Code HI-93750-01
SILICA, LOW RANGE
 Range 0.00 to 2.00 mg/L (as SiO2 )
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method
 Wavelength 610 nm
 Reagent Code HI-93750-01
SILICA, HIGH RANGE
 Range 0 to 200 mg/L (as SiO2 )
 Resolution 1 mg/L
 Accuracy (@25°C) ±1 mg/L ±5% of reading
 Method Adaptation of the USEPA Method 370.1 for drinking, surface and saline waters, domestic and industrial wastes and Standard Method 4500-SiO2
 Wavelength 466 nm
 Reagent Code HI-96770-01
SILVER
 Range 0.000 to 1.000 mg/L (as Ag)
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.020 mg/L ±5% of reading
 Method Adaptation of the PAN method
 Wavelength 575 nm
 Reagent Code HI-93737-01
SULPHATE
 Range 0 to 150 mg/L (as SO42-)
 Resolution 1 mg/L
 Accuracy (@25°C) ±5 mg/L ±3% of reading
 Method Sulphate is precipitated with barium chloride crystals
 Wavelength 466 nm
 Reagent Code HI-93751-01
SURFACTANTS, ANIONIC
 Range 0.00 to 3.50 mg/L (as SDBS)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.04 mg/L ±3% of reading
 Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS
 Wavelength 610 nm
 Reagent Code HI-95769-01
ZINC
 Range 0.00 to 3.00 mg/L (as Zn)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
 Wavelength 575 nm
 Reagent Code HI-93731-01

Reviews

There are no reviews yet.

Be the first to review “HI801 Iris Spectrophotometer” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

  • pH Tester HI98108

    HI98108 pH Tester

  • HI921 Autosampler for Automatic Titrator

    HI921 Autosampler for Automatic Titrator

  • BL983315 TDS Mini Controller

    BL983315 TDS Mini Controller

  • HI98162

    HI98162 Professional Portable Milk pH Meter

Contact Us

  • Unit 26 – No 253 – Kolahdooz Avenue – Tehran – Iran
  • Tel : 0982122799056 , 65
  • Fax : 0982122799073
  • Email: info@sa-aria.com

direction:ltr

Related Links

  • www.hannainst.com
  • www.testometric.co.uk
  • www.xrite.com
  • www.moderner.com
Setare Arsh Aria is a consulting and trading company which would like to improve the quality level of our country’s industries in the fields of laboratory, educational and QC instruments. We believe that our most important asset is the team of people we have at Setare Arsh Aria and the skills they bring to the company.
Setare Arsh Aria is the official agent of many best-known companies. We are trying our best to develop our customers’ knowledge and skills by distributing those companies’ technical knowledge and services.
We would be honored to provide satisfactory and support to our costomers by offering our products with the best quality and reasonable price.
© Copyright - setare arsh aria
HI83325 Multiparameter Photometer HI83325 Multiparameter Photometer HI839800 25 Vial Thermo-Reactor COD HI839800 25 Vial Thermo-Reactor COD
Scroll to top