Description
HI83303 Multiparameter Photometer
The HI83303 is a multiparameter Photometer with very small and modern size to measure water parameters.
HI83303 is proper device for aquaculture industry .
HI83300 measures 12 key water quality parameters.
HI83303 measure pH with a digital pH PROBE.
pH prob in HI83300 measure temperature too.
HI-83303 Aquaculture Photometer with pH meter
HI83303 works with optical system.
HI83303 measure Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.
HI83300 key characteristics been listed as below
- High Efficiency LED Light Source
- High Quality Narrow Band Interference Filters
- Reference Detector for a Stable Light Source
- Large Cuvette Size
- Focusing Lens for Greater Light Yield
Key features of HI83300 ARE AS BELOW:
- Advanced optical system with brighter, long-lasting LED light source
- Backlit 128 x 64 Pixel Graphic Liquid Crystal Display
- Built-in Reaction Timer for Photometric Measurements
- Absorbance mode – concentration versus absorbance
- Units of Measurement plus chemical form displayed
- Result conversion at the touch of a button
- Cuvette cover
- pH and temperature measurement with a single probe
- Good Laboratory Practice (GLP) – track calibration information including date, time, buffers used, offset and slope for traceability
- CAL Check alerts user to potential problems during the calibration process
- Data Logging – Up to 1000 photometric and pH readings can be stored
- Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs
- Battery Status Indicator
- Error Messages
To know HI83303 HANNA price or buy HI83303 Multiparameter Photometer, please contact Setare Arsh Aria company.
HI83303 Multiparameter Photometer Specifications:
Input Channels | 1 pH electrode input and 5 photometer wavelengths | |
pH Electrode | Digital pH electrode (not included) | |
Loggin g type | Log on demand with user name and sample ID optional input | |
Logging Memory | 1000 readings | |
Connectivity | USB-A host for flash drive; micro-USB-B for power and computer connectivity | |
GLP | Calibration data for connected pH electrode | |
Display | 128 x 64 pixel LCD with backlight | |
Battery Type/Life | 3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement | |
Power supply | 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) | |
Environment | 0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing | |
Dimensions | 206 x 177 x 97mm (8.1 x 7.0 x 3.8″) | |
Weight | 1.0 kg (2.2lbs) | |
Photometer/Colorimeter Light Source | 5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters | |
Photometre/Colorimeter Light Detector | Silicon Photodetector | |
Bandpass filter Bandwidth | 8nm | |
Bandpass filter wavelength accruacy | +-1nm | |
Cuvette Type | Round, 24.6mm | |
Number of Methods | 128 Max | |
Ordering Information | HI-83303 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual. |
ALKALINITY | ||
Alkalinity Range | Freshwater: 0 to 500 mg/L (as CaCO3) Marine: 0 to 300 mg/L (as CaCO3) | |
Alkalinity Resolution | 1 mg/L | |
Alkalinity Accuracy | ±5 mg/L ±5% of reading | |
Alkalinity Method | Colorimetric method |
AMMONIA | ||
Ammonia Range | Low Range: 0.00 to 3.00 mg/L (as NH3-N) Medium Range: 0.00 to 10.00 mg/L (as NH3-N) High Range: 0.0 to 100.0 mg/L (as NH3-N) | |
Ammonia Resolution | 0.01 mg/L; 0.1 mg/L | |
Ammonia Accuracy | Low Range: ±0.04 mg/L ±4% of reading Medium Range: ±0.05 mg/L ±5% of reading High range: ±0.5 mg/L ±5% of reading at 25 °C | |
Ammonia Method | Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method |
CALCIUM | ||
Calcium Range | Freshwater: 0 to 400 mg/L (as Ca2+) Marine: 200 to 600 mg/L (as Ca2+) | |
Calcium Resolution | 1 mg/L | |
Calcium Accuracy | Freshwater: ±10 mg/L ±5% of reading Marine: ±6% of reading | |
Calcium Method | Freshwater: Adaptation of the Oxalate method Seawater: Adaptation of the Zincon method |
CHLORINE | ||
Free Chlorine Range | 0.00 to 5.00 mg/L (as Cl2) | |
Free Chlorine Resolution | 0.01 mg/L | |
Free Chlorine Accuracy | ±0.03 mg/L ±3% of reading | |
Total Chlorine Range | 0.00 to 5.00 mg/L (as Cl2) | |
Total Chlorine Resolution | 0.01 mg/L | |
Total Chlorine Accuracy | ±0.03 mg/L ±3% of reading | |
Chlorine Method | Adaptation of the EPA 330.5 DPD method |
COPPER | ||
Copper Range | Low Range: 0.000 to 1.500 mg/L (as Cu2+) High range: 0.00 to 5.00 mg/L (as Cu2+) | |
Copper Resolution | 0.001 mg/L; 0.01 mg/L | |
Copper Accuracy | Low Range: ±0.01 mg/L ±5% of reading High Range ±0.02 mg/L ±4% of reading | |
Copper Method | Adaptation of the EPA bicinchoninate method |
NITRATE | ||
Nitrate Range | 0.0 to 30.0 mg/L (as NO3— N) | |
Nitrate Resolution | 0.1 mg/L | |
Nitrate Accuracy | ±0.5 mg/L ±10% of reading | |
Nitrate Method | Adaptation of the cadmium reduction method |
NITRITE | ||
Nitrite Range | Freshwater Low Range: 0 to 600 μg/L (as NO2–N) High Range: 0 to 150 mg/L (as NO2-) Marine Ultra Low Range: 0 to 200 μg/L (as NO2–N) | |
Nitrite Resolution | Freshwater: 1 μg/L; 1 mg/L Marine: 1 μg/L | |
Nitrite Accuracy | Freshwater Low Range: ±20 μg/L ±4% of reading High Range: ±4 mg/L ±4% of reading Marine: ±10 μg/L ±4% of reading | |
Nitrite Method | Adaptation of the EPA Diazotization method 354.1; HR Ferrous Sulphate |
OXYGEN, DISSOLVED | ||
Oxygen, Dissolved Range | 0.0 to 10.0 mg/L (as O2) | |
Oxygen, Dissolved Resolution | 0.1 mg/L | |
Oxygen, Dissolved Accuracy | ±0.4 mg/L ±3% of reading | |
Oxygen, Dissolved Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method |
pH | ||
pH Range | Photometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH | |
pH Resolution | Photometer: 0.1 pH pH electrode: 0.1 pH | |
pH Accuracy | Photometer: ±0.1 pH pH electrode: ±0.01 pH | |
pH Calibration | Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01) | |
pH Temperature Compensation | Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used | |
pH CAL Check (electrode diagnostics) | clean electrode and check buffer/check probe displayed during calibration | |
pH Method | Photometer: phenol red | |
pH-mV Range | ±1000 mV | |
pH-mV Resolution | 0.1 mV | |
pH-mV Accuracy | ±0.2 mV |
PHOSPHATE | ||
Phosphate Range | Freshwater Low Range: 0.00 to 2.50 mg/L (as PO43-) High range: 0.0 to 30.0 mg/L (as PO43-) Seawater Ultra Low Range: 0 to 200 μg/L (as P) | |
Phosphate Resolution | Freshwater: 0.01 mg/L; 0.1 mg/L Seawater: 1 μg/L | |
Phosphate Accuracy | Freshwater Low Range: ±0.04 mg/L ±4% of reading High Range: ±1 mg/L ±4% of reading Seawater Ultra Low Range: ±5 μg/L ±5% of reading | |
Phosphate Method | Freshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method |
REAGENTS: | ||
Alkalinity | HI-775-26 for freshwater; HI-755-26 for saltwater | |
Ammonia HR & LR | HR – HI-93733-01 (100 tests); HI-93733-03 (300 tests); MR – HI-93715-01 (100 tests); HI-93715-03 (300 tests); LR – HI-93700-01 (100 tests); HI-93700-03 (300 tests) | |
Calcium | HI-937521-01 (50 tests); HI-937521-03 (150 tests) | |
Calcium – Marine | HI-758-26 | |
Chlorine – Free | Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests) | |
Chlorine Total | HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid) | |
Copper – HR, total & LR | HR – HI-93702-01 (100 tests); HI-93702-03 (300 tests) Total copper – HI-93702T – 01 (100 tests); HI-93702T-03 (300 tests) LR – HI-95747-01 (100 tests); HI-95747-03 (300 tests) |
|
Nitrate | HI-93728-01 (100 tests); HI-93728-03 (300 tests) | |
Nitrite – HR & LR | HR – HI-93708-01 (100 tests); HI-93708-03 (300 tests) LR – HI-93707-01 (100 tests); HI-93707-03 (300 tests) |
|
Nitrite – ULR Marine | HI-764-25 | |
Oxygen, Dissolved (DO) | HI-93732-01 (100 tests); HI-93732-03 (300 tests) | |
pH | HI-93710-01 (100 tests); HI-93710-03 (300 tests) | |
Phosphate – ULR Marine | HI-736-25 | |
Phosphate – HR & LR | HR – HI-93717-01 (100 tests); HI-93717-03 (300 tests) LR – HI-93713-01 (100 tests); HI-93713-03 (300 tests) |
Reviews