Give us a call now: 22799067
  • 0Shopping Cart
setare arsh aria
  • Home
  • Chemical Test
    • pH / ORP
      • Tester pH / ORP
      • Portable pH / ORP
      • BenchTop pH / ORP
      • Online pH / ORP
    • EC / TDS
      • Tester EC / TDS
      • Portable EC / TDS
      • BenchTop EC / TDS
      • Online EC / TDS
    • DO (Dissolved Oxygen)
      • Portable DO
      • BenchTop DO
      • Online DO
    • Multiparameter
      • Tester Mutiparameter
      • Portable Multiparameter
      • BenchTop Multiparameter
      • Online Multiparameter
    • Turbidity
      • Portable Turbidity
      • BenchTop Turbidity
    • Photometer / Spectrophotometer
      • Checker
      • Portable Photometer
      • Bench Top Photometer
      • Spectrophotometer
      • COD
    • Titrator / Karl Fisher
      • Titrator
      • Karl Fisher
    • Refractometer
    • Electrodes
      • pH Electrodes
      • ORP Electrodes
      • EC/TDS Electrodes
      • DO Electrodes
      • ISE Electrodes
  • Agencies
  • Blog
    • Articles
    • Seminars
    • Exhibitions
  • Services
    • Guarantee & Warranty
    • Training & Installment
  • About
  • Contact
  • FA
  • Menu
HI83306 Multiparameter Photometer
HI83306 Multiparameter Photometer

HI83306 Multiparameter Photometer

HI83306 Multiparameter Photometer

One meter can be used for both photometric and pH measurements. HI-83306 is a compact, multi-parameter photometer for use in the environmental lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.

Categories: Bench Top Photometer, Bench-top Instruments, BenchTop Multiparameter, Multiparameter Tag: HI83306 Multiparameter Photometer
  • Description
  • Reviews (0)

Description

HI83306 Multiparameter Photometer

HI83306 Multiparameter Photometer

HI83306 Multiparameter Photometer

HI83306 is Multiparameter Photometer with modern and optical design and suit device for  environmental laboratory .

HI83306 works with photometric method.

HI83306 measurs pH via an optional Ph electrode.

 

HI83306

HI83306

HI83306

HI83306

HI83306 measure 16 key water quality parameters with 23 different programmed methods.

HI83306 is useful device to measure Environmental parameters include nitrate, phosphorous and dissolved oxygen.

 

Key features of HI83300 been listed as below:

  • Backlit 128 x 64 Pixel Graphic Liquid Crystal Display
  • Built-in Reaction Timer for Photometric Measurements
  • Absorbance mode – concentration versus absorbance
  • Units of Measurement plus chemical form displayed
  • Result conversion at the touch of a button
  • Cuvette cover
  • pH and temperature measurement with a single probe
  • Good Laboratory Practice (GLP) – track calibration information including date, time, buffers used, offset and slope for traceability
  • pH CAL Check alerts user to potential problems during the calibration process
  • Data Logging – Up to 1000 photometric and pH readings can be stored.
  • Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.
  • Battery Status Indicator
  • Error Messages

HI83306 characteristics been listed as below:

  • High Efficiency LED Light Source
  • High Quality Narrow Band Interference Filters
  • Reference Detector for a Stable Light Source
  • Large Cuvette Size
  • Focusing Lens for Greater Light Yield

 

HI83306 Multiparameter Photometer Specifications

Input Channels 1 pH electrode input and 5 photometer wavelengths
pH Electrode Digital pH electrode (not included)
Logging type Log on demand with user name and sample ID optional input
Logging Memory 1000 readings
Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity
GLP Calibration data for connected pH electrode
Display 128 x 64 pixel LCD with backlight
Battery Type/Life 3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement
Power supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
Environment 0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing
Dimensions 206 x 177 x 97mm (8.1 x 7.0 x 3.8″)
Weight 1.0 kg (2.2lbs)
Photometer/Colorimeter Light Source 5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters
Photometre/Colorimeter Light Detector Silicon Photodetector
Bandpass filter Bandwidth 8nm
Bandpass filter wavelength accruacy +-1nm
Cuvette Type Round, 24.6mm
Number of Methods 128 Max
Ordering Information HI-83306 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.
AMMONIA
Ammonia Range Low Range: 0.00 to 3.00 mg/L (as NH3-N) Medium Range: 0.00 to 10.00 mg/L (as NH3-N) High Range: 0.0 to 100.0 mg/L (as NH3-N)
Ammonia Resolution 0.01 mg/L; 0.1 mg/L
Ammonia Accuracy Low Range: ±0.04 mg/L ±4% of reading Medium Range: ±0.05 mg/L ±5% of reading High range: ±0.5 mg/L ±5% of reading at 25 °C
Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method
CHLORINE
Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Free Chlorine Resolution 0.01 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading
Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Total Chlorine Resolution 0.01 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading
Chlorine Method Adaptation of the EPA 330.5 DPD method
CHROMIUM, HEXAVALENT
Chromium, Hexavalent Range Low Range: 0 to 300 μg/L (as Cr6+) High Range: 0 to 1000 μg/L (as Cr6+)
Chromium, Hexavalent Resolution 1 μg/L
Chromium, Hexavalent Accuracy Low Range: ±1 μg/L ±4% of reading High Range: ±5 μg/L ±4% of reading
Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.
COLOUR, WATER
Colour, Water Range 0 to 500 PCU (Platinum Cobalt Units)
Colour, Water Resolution 1 PCU
Colour, Water Accuracy ±10 PCU ±5% of reading
Colour, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method.
COPPER
Copper Range Low Range: 0.000 to 1.500 mg/L (as Cu2+) High range: 0.00 to 5.00 mg/L (as Cu2+)
Copper Resolution 0.001 mg/L; 0.01 mg/L
Copper Accuracy Low Range: ±0.01 mg/L ±5% of reading High Range ±0.02 mg/L ±4% of reading
Copper Method Adaptation of the EPA bicinchoninate method
CYANURIC ACID
Cyanuric Acid Range 0 to 80 mg/L (as CYA)
Cyanuric Acid Resolution 1 mg/L
Cyanuric Acid Accuracy ±1 mg/L ±15% of reading
Cyanuric Acid Method Adaptation of the turbidimetric method
MOLYBDENUM
Molybdenum Range 0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution 0.1 mg/L
Molybdenum Accuracy ±0.3 mg/L ±5% of reading
Molybdenum Method Adaptation of the mercaptoacetic acid method
NICKEL
Nickel Range Low Range: 0.000 to 1.000 mg/L (as Ni) High Range: 0.00 to 7.00 g/L (as Ni)
Nickel Resolution 0.001 mg/L; 0.01 g/L
Nickel Accuracy Low range: ±0.010 mg/L ±7% of reading High Range: ±0.07 g/L ±4% of reading
Nickel Method Low Range: Adaptation of the PAN method High Range: Adaptation of the photometric method
NITRATE
Nitrate Range 0.0 to 30.0 mg/L (as NO3– N)
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading
Nitrate Method Adaptation of the cadmium reduction method
NITRITE
Nitrite Range Freshwater High Range: 0 to 150 mg/L (as NO2-)
Nitrite Resolution Freshwater: 1 mg/L
Nitrite Accuracy Freshwater High Range: ±4 mg/L ±4% of reading
Nitrite Method HR – Adaptation of the Ferrous Sulphate method
OXYGEN, DISSOLVED
Oxygen, Dissolved Range 0.0 to 10.0 mg/L (as O2)
Oxygen, Dissolved Resolution 0.1 mg/L
Oxygen, Dissolved Accuracy ±0.4 mg/L ±3% of reading
Oxygen, Dissolved Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
pH
pH Range Photometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH
pH Resolution Photometer: 0.1 pH pH electrode: 0.1 pH
pH Accuracy Photometer: ±0.1 pH pH electrode: ±0.01 pH
pH Calibration Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature Compensation Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used
pH CAL Check (electrode diagnostics) clean electrode and check buffer/check probe displayed during calibration
pH Method Photometer: phenol red
pH-mV Range ±1000 mV
pH-mV Resolution 0.1 mV
pH-mV Accuracy ±0.2 mV
PHOSPHATE
Phosphate Range Freshwater Low Range: 0.00 to 2.50 mg/L (as PO43-) High range: 0.0 to 30.0 mg/L (as PO43-)
Phosphate Resolution Freshwater: 0.01 mg/L; 0.1 mg/L
Phosphate Accuracy Freshwater Low Range: ±0.04 mg/L ±4% of reading High Range: ±1 mg/L ±4% of reading
Phosphate Method Freshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method
SILICA
Silica Range Low Range: 0.00 to 2.00 mg/L (as SiO2)
Silica Resolution 0.01 mg/L
Silica Accuracy Low Range: ±0.03 mg/L ±3% of reading
Silica Method Low Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method
SILVER
Silver Range 0.000 to 1.000 mg/L (as Ag)
Silver Resolution 0.001 mg/L
Silver Accuracy ±0.020 mg/L ±5% of reading
Silver Method Adaptation of the PAN method
ZINC
Zinc Range 0.00 to 3.00 mg/L (as Zn)
Zinc Resolution 0.01 mg/L
Zinc Accuracy ±0.03 mg/L ±3% of reading
Zinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
REAGENTS
Ammonia HR, MR & LR HR – HI-93733-01 (100 tests); HI-93733-03 (300 tests); MR – HI-93715-01 (100 tests); HI-93715-03 (300 tests); LR – HI-93700-01 (100 tests); HI-93700-03 (300 tests)
Chlorine – Free Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)
Chlorine Total HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)
Chlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)
Chromium VI – HR & LR HR – HI-93723-01 (100 tests); HI-93723-03 (300 tests)
LR – HI-93749-01 (100 tests); HI-93749-03 (300 tests)
Copper – HR & LR HR – HI-93702-01 (100 tests); HI-93702-03 (300 tests)
LR – HI-95747-01 (100 tests); HI-95747-03 (300 tests)
Cyanuric Acid HI-93722-01 (100 tests); HI-93722-03 (300 tests)
Molybdenum HI-93730-01 (100 tests); HI-93730-03 (300 tests)
Nickel – HR & LR HR – HI-93726-01 (100 tests); HI-93726-03 (300 tests)
LR – HI-93740-01 (50 tests); HI-93740-03 (150 tests)
Nitrate HI-93728-01 (100 tests); HI-93728-03 (300 tests)
Nitrite – HR & LR HR – HI-93708-01 (100 tests); HI-93708-03 (300 tests)
LR – HI-93707-01 (100 tests); HI-93707-03 (300 tests)
Oxygen, Dissolved (DO) HI-93732-01 (100 tests); HI-93732-03 (300 tests)
pH HI-93710-01 (100 tests); HI-93710-03 (300 tests)
Phosphate – HR & LR HR – HI-93717-01 (100 tests); HI-93717-03 (300 tests)
LR – HI-93713-01 (100 tests); HI-93713-03 (300 tests)
Silica – LR LR – HI-93705-01 (100 tests); HI-93705-03 (300 tests)
Silver HI-93737-01 (50 tests); HI-93737-03 (150 tests)
Zinc HI-93731-01 (100 tests); HI-93731-03 (300 tests)

To know HI83306 HANNA price or buy HI83306 Multiparameter Photometer ,please contact Setare Arsh Aria company.

Reviews

There are no reviews yet.

Be the first to review “HI83306 Multiparameter Photometer” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

  • HI98199 Multiparameter

    HI98199 Multiparameter

  • HI83314 Multiparameter with COD photometer

    HI83314 Multiparameter with COD photometer

  • HI83303 Multiparameter Photometer

    HI83303 Multiparameter Photometer

  • HI2300 EC/TDS/NaCl/°C Meter

    HI2300 EC/TDS/NaCl/°C Meter

Contact Us

  • Unit 26 – No 253 – Kolahdooz Avenue – Tehran – Iran
  • Tel : 0982122799056 , 65
  • Fax : 0982122799073
  • Email: info@sa-aria.com

direction:ltr

Related Links

  • www.hannainst.com
  • www.testometric.co.uk
  • www.xrite.com
  • www.moderner.com
Setare Arsh Aria is a consulting and trading company which would like to improve the quality level of our country’s industries in the fields of laboratory, educational and QC instruments. We believe that our most important asset is the team of people we have at Setare Arsh Aria and the skills they bring to the company.
Setare Arsh Aria is the official agent of many best-known companies. We are trying our best to develop our customers’ knowledge and skills by distributing those companies’ technical knowledge and services.
We would be honored to provide satisfactory and support to our costomers by offering our products with the best quality and reasonable price.
© Copyright - setare arsh aria
HI96711C Chlorine Free and Total Photometer HI96711C Chlorine Free and Total Photometer HI83303 Multiparameter Photometer HI83303 Multiparameter Photometer
Scroll to top