Give us a call now: 22799067
  • 0Shopping Cart
setare arsh aria
  • Home
  • Chemical Test
    • pH / ORP
      • Tester pH / ORP
      • Portable pH / ORP
      • BenchTop pH / ORP
      • Online pH / ORP
    • EC / TDS
      • Tester EC / TDS
      • Portable EC / TDS
      • BenchTop EC / TDS
      • Online EC / TDS
    • DO (Dissolved Oxygen)
      • Portable DO
      • BenchTop DO
      • Online DO
    • Multiparameter
      • Tester Mutiparameter
      • Portable Multiparameter
      • BenchTop Multiparameter
      • Online Multiparameter
    • Turbidity
      • Portable Turbidity
      • BenchTop Turbidity
    • Photometer / Spectrophotometer
      • Checker
      • Portable Photometer
      • Bench Top Photometer
      • Spectrophotometer
      • COD
    • Titrator / Karl Fisher
      • Titrator
      • Karl Fisher
    • Refractometer
    • Electrodes
      • pH Electrodes
      • ORP Electrodes
      • EC/TDS Electrodes
      • DO Electrodes
      • ISE Electrodes
  • Agencies
  • Blog
    • Articles
    • Seminars
    • Exhibitions
  • Services
    • Guarantee & Warranty
    • Training & Installment
  • About
  • Contact
  • FA
  • Menu
HI83399 multiparameter with COD photometer
HI83399 multiparameter with COD photometer

HI83399 multiparameter with COD photometer

HI83399 multiparameter with COD photometer

HI83399 multiparameter with COD photometer

HI83399 multiparameter with COD photometer

HI-83399 Water and wastewater multi-parameter with COD photometer & pH meter

One meter can be used for both photometric and pH measurements. HI-83399 is a compact, multi-parameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available, with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and imperfections in the glass cuvette.

Categories: Bench Top Photometer, BenchTop Multiparameter, COD, Multiparameter Tags: HI83399 multiparameter photometer, HI83399 multiparameter with COD photometer
  • Description
  • Reviews (0)

Description

8HI83399 multiparameter with COD photometer

HI83399 multiparameter with COD photometer

HI83399 multiparameter with COD photometer

The HI83399 is a benchtop multiparameter photometer that can measure COD and pH .

The dimension of HI83399 is small and suitable for measuring the key water parameters and water quality control  .The HI83399 measure by optical design.

HI-83399 Water and wastewater multi-parameter with COD photometer & pH meter

HI83399 is proper device for using in water and wast water industry to measure 40 key water and wastewater quality parameters with 73 different methods .

HI83399 multiparameter with COD photometer

HI83399 multiparameter with COD photometer

 

HI88399 Key features been listed below:

  • Advanced optical system with brighter, long-lasting LED light source
  • Backlit 128 x 64 Pixel Graphic Liquid Crystal Display
  • Built-in Reaction Timer for Photometric Measurements
  • Absorbance mode – concentration versus absorbance
  • Units of Measurement plus chemical form displayed
  • Result conversion at the touch of a button
  • Cuvette cover
  • pH and temperature measurement with a single probe
  • Good Laboratory Practice (GLP) – track calibration information including date, time, buffers used, offset and slope for traceability
  • CAL Check alerts user to potential problems during the calibration process
  • Data Logging – Up to 1000 photometric and pH readings can be stored
  • Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs
  • Battery Status Indicator
  • Error Messages

HI83399 TOPIC characteristics been listed below: 

  • High Efficiency LED Light Source
  • High Quality Narrow Band Interference Filters
  • Reference Detector for a Stable Light Source
  • Large Cuvette Size
  • Focusing Lens for Greater Light Yield

 

To know HI83399 HANNA price or buy HI83399 multiparameter with COD photometer , please contact Setare Arsh Aria company.

Specifications

Specifications list

Specifications

Input Channels 1 pH electrode input and 5 photometer wavelengths
pH Electrode Digital pH electrode (not included)
Logging type Log on demand with user name and sample ID optional input
Logging Memory 1000 readings
Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity
GLP Calibration data for connected pH electrode
Display 128 x 64 pixel LCD with backlight
Battery Type/Life 3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement
Power supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
Environment 0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing
Dimensions 206 x 177 x 97mm (8.1 x 7.0 x 3.8″)
Weight 1.0 kg (2.2lbs)
Photometer/Colorimeter Light Source 5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters
Photometre/Colorimeter Light Detector Silicon Photodetector
Bandpass filter Bandwidth 8nm
Bandpass filter wavelength accruacy +-1nm
Cuvette Type Round, 24.6mm
Number of Methods 128 Max
Ordering Information HI-83399 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.
ALKALINITY
Alkalinity Range Freshwater: 0 to 500 mg/L (as CaCO3) Marine: 0 to 300 mg/L (as CaCO3)
Alkalinity Resolution 1 mg/L
Alkalinity Accuracy ±5 mg/L ±5% of reading
Alkalinity Method Bromocresol green method
ALUMINIUM
Aluminium Range 0.00 to 1.00 mg/L (as Al3+)
Aluminium Resolution 0.01 mg/L
Aluminium Accuracy ±0.04 mg/L ±4% of reading
Aluminium Method Adaptation of the aluminon method
AMMONIA
Ammonia Range Low Range: 0.00 to 3.00 mg/L (as NH3-N) Medium Range: 0.00 to 10.00 mg/L (as NH3-N) High Range: 0.0 to 100.0 mg/L (as NH3-N)
Ammonia Resolution 0.01 mg/L; 0.1 mg/L
Ammonia Accuracy Low Range: ±0.04 mg/L ±4% of reading Medium Range: ±0.05 mg/L ±5% of reading High range: ±0.5 mg/L ±5% of reading at 25 °C
Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method
BROMINE
Bromine Range 0.00 to 8.00 mg/L (as Br2)
Bromine Resolution 0.01 mg/L
Bromine Accuracy ±0.08 mg/L ±3% of reading
Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.
CALCIUM
Calcium Range Freshwater: 0 to 400 mg/L (as Ca2+) Marine: 200 to 600 mg/L (as Ca2+)
Calcium Resolution 1 mg/L
Calcium Accuracy Freshwater: ±10 mg/L ±5% of reading Marine: ±6% of reading
Calcium Method Freshwater: Adaptation of the Oxalate method Seawater: Adaptation of the Zincon method
CHLORIDE
Chloride Range 0.0 to 20.0 mg/L (as Cl⁻)
Chloride Resolution 0.1 mg/L
Chloride Accuracy ±0.5 mg/L ±6% of reading at 25 °C
CHLORINE DIOXIDE
Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2)
Chlorine Dioxide Resolution 0.01 mg/L
Chlorine Dioxide Accuracy ±0.10 mg/L ±5% of reading
Chlorine Dioxide Method Adaptation of the Chlorophenol Red method.
CHLORINE
Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2)
Free Chlorine Resolution 0.01 mg/L Ultra Low Range: 0.001 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading Ultra Low Range: ±0.020 mg/L ±3% of reading
Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2) Ultra High Range: 0 to 500 mg/L (as Cl2)
Total Chlorine Resolution 0.01 mg/L; 0.001 mg/L; 1 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading Ultra Low Range: ±0.020 mg/L ±3% of reading Ultra High Range: ±3 mg/L ±3% of reading
Chlorine Method Adaptation of the EPA 330.5 DPD method Free Chlorine (ULR) & Total Chlorine (UHR): Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl
CHROMIUM, HEXAVALENT
Chromium, Hexavalent Range Low Range: 0 to 300 μg/L (as Cr6+) High Range: 0 to 1000 μg/L (as Cr6+)
Chromium, Hexavalent Resolution 1 μg/L
Chromium, Hexavalent Accuracy Low Range: ±1 μg/L ±4% of reading High Range: ±5 μg/L ±4% of reading
Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.
COD
COD Low, Medium & High Range Low Range: 0 to 150 mg/L (as O2) Medium Range: 0 to 1500 mg/L (as O2) High Range: 0 to 15000 mg/L (as O2
Resolution 1mg/L
Accuracy Low Range: ±5 mg/L ±4% of reading Medium Range: ±15 mg/L ±4% of reading High Range: ±150 mg/L or ±2% of reading
Method Low and medium range: dichromate mercury-free High Range: dichromate
COLOUR, WATER
Colour, Water Range 0 to 500 PCU (Platinum Cobalt Units)
Colour, Water Resolution 1 PCU
Colour, Water Accuracy ±10 PCU ±5% of reading
Colour, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method.
COPPER
Copper Range Low Range: 0.000 to 1.500 mg/L (as Cu2+) High range: 0.00 to 5.00 mg/L (as Cu2+)
Copper Resolution 0.001 mg/L; 0.01 mg/L
Copper Accuracy Low Range: ±0.01 mg/L ±5% of reading High Range ±0.02 mg/L ±4% of reading
Copper Method Adaptation of the EPA bicinchoninate method
CYANURIC ACID
Cyanuric Acid Range 0 to 80 mg/L (as CYA)
Cyanuric Acid Resolution 1 mg/L
Cyanuric Acid Accuracy ±1 mg/L ±15% of reading
Cyanuric Acid Method Adaptation of the turbidimetric method
FLUORIDE
Fluoride Range Low Range: 0.00 to 2.00 mg/L (as F-) High range: 0.0 to 20.0 mg/L (as F-)
Fluoride Resolution 0.01 mg/L; 0.1 mg/L
Fluoride Accuracy Low Range: ±0.03 mg/L ±3% of reading High Range: ±0.5 mg/L ±3% of reading
Fluoride Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
HARDNESS, CALCIUM
Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3)
Hardness, Calcium Resolution 0.01 mg/L
Hardness, Calcium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method
HARDNESS, MAGNESIUM
Hardness, Magnesium Range 0.00 to 2.00 mg/L (as CaCO3)
Hardness, Magnesium Resolution 0.01 mg/L
Hardness, Magnesium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method (Calmagite)
HARDNESS, TOTAL
Hardness, Total Range Low Range: 0 to 250 mg/L (as CaCO3) Medium Range: 200 to 500 mg/L (as CaCO3) High Range: 400 to 750 mg/L (as CaCO3)
Hardness, Total Resolution 1 mg/L
Hardness, Total Accuracy Low Range: ±5 mg/L ±4% of reading Medium Range: ±7 mg/L ±3% of reading High Range: ±10 mg/L ±2% of reading
Hardness, Total Method Calmagite
HYDRAZINE
Hydrazine Range 0 to 400 μg/L (as N2H4)
Hydrazine Resolution 1 μg/L
Hydrazine Accuracy ±4% of full scale reading
Hydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method
IODINE
Iodine Range 0.0 to 12.5 mg/L (as I2)
Iodine Resolution 0.1 mg/L
Iodine Accuracy ±0.1 mg/L ±5% of reading
Iodine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
IRON
Iron Range Low Range: 0.000 to 1.600 mg/L (as Fe) High Range: 0.00 to 5.00 mg/L (as Fe)
Iron Resolution 0.001 mg/L; 0.01 mg/L
Iron Accuracy Low Range: ±0.01 mg/L ±8% of reading High Range: ±0.04 mg/L ±2% of reading
Iron Method Low Range: Adaptation of the TPTZ Method High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters
MAGNESIUM
Magnesium Range 0 to 150 mg/L (as Mg2+)
Magnesium Resolution 1 mg/L
Magnesium Accuracy ±5 mg/L ±3% of reading
Magnesium Method Adaptation of the Calmagite method
MANGANESE
Manganese Range Low Range: 0 to 300 µg/L (as Mn) High range: 0.0 to 20.0 mg/L (as Mn)
Manganese Resolution 1 µg/L; 0.1 mg/L
Manganese Accuracy Low Range: ±10 µg/L ±3% of reading High Range: ±0.3 mg/L ±5% of reading
Manganese Method Low Range: Adaptation of the PAN Method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method
MOLYBDENUM
Molybdenum Range 0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution 0.1 mg/L
Molybdenum Accuracy ±0.3 mg/L ±5% of reading
Molybdenum Method Adaptation of the mercaptoacetic acid method
NICKEL
Nickel Range Low Range: 0.000 to 1.000 mg/L (as Ni) High Range: 0.00 to 7.00 g/L (as Ni)
Nickel Resolution 0.001 mg/L; 0.01 g/L
Nickel Accuracy Low range: ±0.010 mg/L ±7% of reading High Range: ±0.07 g/L ±4% of reading
Nickel Method Low Range: Adaptation of the PAN method High Range: Adaptation of the photometric method
NITRATE
Nitrate Range 0.0 to 30.0 mg/L (as NO3— N)
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading
Nitrate Method Adaptation of the cadmium reduction method
NITRITE
Nitrite Range Freshwater Low Range: 0 to 600 μg/L (as NO2–N) High Range: 0 to 150 mg/L (as NO2-) Marine Ultra Low Range: 0 to 200 μg/L (as NO2–N)
Nitrite Resolution Freshwater: 1 μg/L; 1 mg/L Marine: 0.1 mg/L
Nitrite Accuracy Freshwater Low Range: ±20 μg/L ±4% of reading High Range: ±4 mg/L ±4% of reading Marine: ±0.5 mg/L ±10% of reading
Nitrite Method Adaptation of the EPA Diazotization method 354.1; HR Ferrous Sulphate; Cadium Reduction
NITROGEN
Nitrogen, Total Low & High Range Total Low Range: 0.0 to 25.0 mg/L (as NO3–-N) High Range: 0 to 150 mg/L (as N)
Resolution 1mg/L
Accuracy Low Range: ±1.0 mg/L ±5% of reading High Range: ±3 mg/L or ±4% of reading
Method Chromotropic acid
OXYGEN, DISSOLVED
Oxygen, Dissolved Range 0.0 to 10.0 mg/L (as O2)
Oxygen, Dissolved Resolution 0.1 mg/L
Oxygen, Dissolved Accuracy ±0.4 mg/L ±3% of reading
Oxygen, Dissolved Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
OXYGEN, SCAVENGER
Oxygen, Scavenger Range 0 to 1000 μg/L (as DEHA) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.00 to 2.50 mg/L (as Hydroquinone) 0.00 to 4.50 mg/L (as ISO-ascorbic acid)
Oxygen, Scavenger Resolution 1 μg/L (DEHA); 0.01 mg/L
Oxygen, Scavenger Accuracy ±5 μg/L ±5% of reading
Oxygen, Scavenger Method Adaptation of the iron reduction method
OZONE
Ozone Range 0.00 to 2.00 mg/L (as O3)
Ozone Resolution 0.01 mg/L
Ozone Accuracy ±0.02 mg/L ±3% of reading
Ozone Method Colorimetric DPD Method
pH
pH Range 6.5 to 8.5 pH
pH Resolution 0.1 pH
pH Accuracy ±0.1 pH
pH Method phenol red
PHOSPHATE
Phosphate Range Freshwater Low Range: 0.00 to 2.50 mg/L (as PO43-) High range: 0.0 to 30.0 mg/L (as PO43-) Seawater Ultra Low Range: 0 to 200 μg/L (as P)
Phosphate Resolution Freshwater: 0.01 mg/L; 0.1 mg/L Seawater: 1 μg/L
Phosphate Accuracy Freshwater Low Range: ±0.04 mg/L ±4% of reading High Range: ±1 mg/L ±4% of reading Seawater Ultra Low Range: ±5 μg/L ±5% of reading
Phosphate Method Freshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method
POTASSIUM
Potassium Range 0.0 to 20.0 mg/L (as K)
Potassium Resolution 0.1 mg/L
Potassium Accuracy ±3.0 mg/L ±7% of reading
Potassium Method Adaptation of the Turbidimetric Tetraphenylborate method
SILICA
Silica Range Low Range: 0.00 to 2.00 mg/L (as SiO2) High Range: 0 to 200 mg/L (as SiO2)
Silica Resolution 0.01 mg/L; 1 mg/L
Silica Accuracy Low Range: ±0.03 mg/L ±3% of reading High Range: ±1 mg/L ±5% of reading
Silica Method Low Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method High Range: Adaptation of the USEPA Method 370.1 and Standard Method 4500-SiO2
SILVER
Silver Range 0.000 to 1.000 mg/L (as Ag)
Silver Resolution 0.001 mg/L
Silver Accuracy ±0.020 mg/L ±5% of reading
Silver Method Adaptation of the PAN method
SULPHATE
Sulphate Range 0 to 150 mg/L (as SO42-)
Sulphate Resolution 1 mg/L
Sulphate Accuracy ±5 mg/L ±3% of reading
Sulphate Method Turbidimetric – Sulphate is precipitated with barium chloride crystals
SURFACTANTS, ANIONIC
Range 0.0 to 3.50 mg/L (as SDBS)
Resolution 0.01mg/L
Accuracy ±0.04 mg/L ±3% of reading
Method Methylene blue
ZINC
Zinc Range 0.00 to 3.00 mg/L (as Zn)
Zinc Resolution 0.01 mg/L
Zinc Accuracy ±0.03 mg/L ±3% of reading
Zinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
REAGENTS
Alkalinity HI-93755-01 (100 tests); HI-93755-03 (300 tests)
Aluminium HI-93712-01 (100 tests); HI-93712-03 (300 tests)
Ammonia HR, MR & LR HR – HI-93733-01 (100 tests); HI-93733-03 (300 tests); MR – HI-93715-01 (100 tests); HI-93715-03 (300 tests); LR – HI-93700-01 (100 tests); HI-93700-03 (300 tests)
Bromine HI-93716-01 (100 tests); HI-93716-03 (300 tests)
Calcium HI-937521-01 (50 tests); HI-937521-03 (150 tests)
Calcium and Magnesium HI-93752-01 (50 x 2 tests) HI-93752-03 (150 x 2 tests)
Chloride HI-93753-01 (100 tests); HI-93753-03 (300 Tests)
Chlorine Dioxide Reagents: HI-93738-01 (100 tests); HI-93738-03 (300 tests)
Chlorine – Free Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)
Chlorine UHR HI-95771-01 (100 tests); HI-95771-03 (300 tests)
Chlorine, Free and Total HR HI-93734-01 (100 tests); HI-93734-03 (300 tests)
Chlorine, Free ULR HI-95762-01 (100 tests); HI-95762-03 (300 tests)
Chlorine Total HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)
Chlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)
Chromium VI – HR & LR HR – HI-93723-01 (100 tests); HI-93723-03 (300 tests)
LR – HI-93749-01 (100 tests); HI-93749-03 (300 tests)
Copper – HR, total & LR HR – HI-93702-01 (100 tests); HI-93702-03 (300 tests)
Total copper – HI-93702T – 01 (100 tests); HI-93702T-03 (300 tests)
LR – HI-95747-01 (100 tests); HI-95747-03 (300 tests)
Cyanide HI-93714-01 (100 tests); HI-93714-03 (300 tests)
Cyanuric Acid HI-93722-01 (100 tests); HI-93722-03 (300 tests)
Detergents, Anionic HI-95769-01 (40 tests)
Fluoride – HR & LR HR – HI-93739-01 (100 tests); HI-93739-03 (300 tests)
LR – HI-93729-01 (100 tests); HI-93729-03 (300 tests)
Glycine Powder HI-93703-52 (100 tests)
Hardness, Calcium HI-93720-01 (100 tests); HI-93720-03 (300 tests)
Hardness, Magnesium and total hardness HI-93719-01 (100 tests); HI-93719-03 (300 tests)
Hardness, total HR, MR, LR and Total LR+MR+LR HR – HI-93735-02 (100 tests); MR – HI-93735-01 (100 tests); LR – HI-93735-00 (100 tests); HR MR &LR – HI-93735-0 (100 x 3 tests)
Hydrazine HI-93704-01 (100 tests); HI-93704-03 (300 tests)
Iodine HI-93718-01 (100 tests); HI-93718-03 (300 tests)
Iron – HR & LR HR – HI-93721-01 (100 tests); HI-93721-03 (300 tests)
LR – HI-93746-01 (100 tests); HI-93746-03 (300 tests)
Manganese – HR & LR HR – HI-93709-01 (100 tests); HI-93709-03 (300 tests)
LR – HI-93748-01 (50 tests); HI-93748-03 (150 tests)
Magnesium HI-937520-01 (50 tests); HI-937520-03 (150 tests)
Molybdenum HI-93730-01 (100 tests); HI-93730-03 (300 tests)
Nickel – HR & LR HR – HI-93726-01 (100 tests); HI-93726-03 (300 tests)
LR – HI-93740-01 (50 tests); HI-93740-03 (150 tests)
Nitrate HI-93728-01 (100 tests); HI-93728-03 (300 tests)
Nitrite – HR & LR HR – HI-93708-01 (100 tests); HI-93708-03 (300 tests)
LR – HI-93707-01 (100 tests); HI-93707-03 (300 tests)
Oxygen, Dissolved (DO) HI-93732-01 (100 tests); HI-93732-03 (300 tests)
Ozone HI-93757-01 (100 tests); HI-93757-03 (300 tests)
pH HI-93710-01 (100 tests); HI-93710-03 (300 tests)
Phosphate – HR & LR HR – HI-93717-01 (100 tests); HI-93717-03 (300 tests)
LR – HI-93713-01 (100 tests); HI-93713-03 (300 tests)
Phosphorus HI-93706-01 (100 tests); HI-93706-03 (300 tests)
Potassium HI-93750-01 (100 tests); HI-93750-03 (300 tests)
Silica – HR & LR HR – HI-96770-01 (100 tests); HI-96770-03 (300 tests)
LR – HI-93705-01 (100 tests); HI-93705-03 (300 tests)
Silver HI-93737-01 (50 tests); HI-93737-03 (150 tests)
Sulphate HI-93751-01 (100 tests); HI-93751-03 (300 tests)
Zinc HI-93731-01 (100 tests); HI-93731-03 (300 tests)

Reviews

There are no reviews yet.

Be the first to review “HI83399 multiparameter with COD photometer” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

  • HI98131 Multiparameter Tester

    HI98131 Multiparameter Tester

  • Multiparameter 2020-2030-2040

    Multiparameter 2020-2030-2040

  • HI98130 Multiparameter Tester

    HI98130 Multiparameter Tester

  • HI98129 COMBO Tester for pH/EC/TDS/C°

    HI98129 Multi parameter

Contact Us

  • Unit 26 – No 253 – Kolahdooz Avenue – Tehran – Iran
  • Tel : 0982122799056 , 65
  • Fax : 0982122799073
  • Email: info@sa-aria.com

direction:ltr

Related Links

  • www.hannainst.com
  • www.testometric.co.uk
  • www.xrite.com
  • www.moderner.com
Setare Arsh Aria is a consulting and trading company which would like to improve the quality level of our country’s industries in the fields of laboratory, educational and QC instruments. We believe that our most important asset is the team of people we have at Setare Arsh Aria and the skills they bring to the company.
Setare Arsh Aria is the official agent of many best-known companies. We are trying our best to develop our customers’ knowledge and skills by distributing those companies’ technical knowledge and services.
We would be honored to provide satisfactory and support to our costomers by offering our products with the best quality and reasonable price.
© Copyright - setare arsh aria
HI83303 Multiparameter Photometer HI83303 Multiparameter Photometer HI83300 Multiparameter Photometer HI83300 Multiparameter Photometer
Scroll to top