Description
HI98195 Multiparameter
HI98195 Multiparameter – pH / ORP / EC / TDS / Salinity / Temp – with Complete Set
Product information “HI98195 Multiparameter – pH / ORP / EC / TDS / Salinity / Temp – with Complete Set”
HI98195 is a multiparameter HANNA device that measure PH/EC/TDS/SALINITY /TEMP.
HI98195 is a Rugged, waterproof instrument.
HI98195 is very easy to use, the HI 98195 is the ideal meters for field measurements of lakes, rivers and seas.
The HI 98195 is suit multi parameter to measure the paramets of water and control water quality parameters such as pH, ORP, conductivity, temperature, resistivity, TDS, salinity, and seawater specific gravity.
HI98195 such as other HI9819X series has GLP feature.
To know HI98195 HANNA price or buy HI98195 Multiparameter ,please contact Setare Arsh Aria company.
HI98195 Multiparameter Specification :
pH Range | 0.00 to 14.00 pH |
---|---|
pH Resolution | 0.01 pH |
pH Accuracy | ±0.02 pH |
pH Calibration | automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
mV Range | ±600.0 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.5 mV |
ORP Range | ±2000.0 mV |
ORP Resolution | 0.1 mV |
ORP Accuracy | ±1.0 mV |
ORP Calibration | automatic at one custom point (relative mV) |
EC Range | 0 to 9999 µS/cm; 0.000 to 200.0 mS/cm (absolute EC up to 400.0 mS/cm) |
EC Resolution | auto-ranging: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; auto-ranging (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; manual: 1 µS/cm; 0.001 mS/cm; 0.01 |
EC Accuracy | ±1% of reading or ±1 µS/cm whichever is greater |
EC Calibration | automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
TDS Range | 0 to 9999 ppm (mg/L); 0.000 to 400.0 ppt (g/L) (maximum value depends on TDS factor) |
TDS Resolution | manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt): |
TDS Accuracy | ±1% of reading or ±1 ppm (mg/L), whichever is greater |
TDS Calibration | based on conductivity calibration |
Resistivity Range | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
Resistivity Resolution | dependent on resistivity reading |
Resistivity Calibration | based on conductivity calibration |
Salinity Range | 0.00 to 70.00 PSU |
Salinity Resolution | 0.01 PSU |
Salinity Accuracy | ±2% of reading or ±0.01 PSU whichever is greater |
Salinity Calibration | based on conductivity calibration |
Seawater σ Range | 0.0 to 50.0 σt, σ₀, σ₁₅ |
Seawater σ Resolution | 0.1 σt, σ₀, σ₁₅ |
Seawater σ Accuracy | ±1 σt, σ₀, σ₁₅ |
Seawater σ Calibration | based on conductivity calibration |
Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Atmospheric Pressure Accuracy | ±3 mm Hg within ±15°C from the temperature during calibration |
Atmospheric Pressure Calibration | automatic at one custom point |
Temperature Range | -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
Temperature Resolution | 0.01 K, 0.01 °C, 0.01 °F |
Temperature Accuracy | ±0.15 °C; ±0.27 °F; ±0.15 K |
Temperature Calibration | automatic at one custom point |
Temperature Compensation | automatic from -5 to 55 °C (23 to 131 °F) |
Logging Memory | 45,000 records (continuous logging or log-on-demand of all parameters) |
Logging Interval | one second to three hours |
PC Connectivity | USB to PC with HI9298194 Hanna software installed |
Battery Type/Life | 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight) With probe connected, approximately 104 hours of continuous use without backlight. |
Environment | 0 to 50°C (32 to 122°F); RH 100% (IP67) |
Dimensions | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) |
Weight | 400 g (14.2 oz.) |
Ordering Information | HI98195 is supplied with HI7698195 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI 76981952 Probe maintenance kit (O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert. |
Reviews