{"id":4074,"date":"2020-11-23T16:16:34","date_gmt":"2020-11-23T17:16:34","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4074"},"modified":"2024-08-14T18:31:49","modified_gmt":"2024-08-14T18:31:49","slug":"hi98197-ultra-pure-water-ec-resistivity-portable-meter","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi98197-ultra-pure-water-ec-resistivity-portable-meter\/","title":{"rendered":"HI98197 Ultra Pure Water EC\/Resistivity Portable Meter"},"content":{"rendered":"<h2>HI98197 Ultra Pure Water EC\/Resistivity Portable Meter<\/h2>\n<h3>Product information &#8220;HI98197 Ultra Pure Water EC\/Resistivity Waterproof Portable Meter&#8221;<\/h3>\n<p>HI98197 is portable EC\/Resestivity meter only for measuring conductivity of dionized water.<\/p>\n<p>HI98197 is rugged and water proof device .<\/p>\n<p>HI98197 is packed in hard carrying case to be carry safe by user to everywhere.<\/p>\n<p>HI98197 probe is HI76312.<\/p>\n<p>HI76312 probe is four- ring probe for 0.001 \u03bcS\/cm.<\/p>\n<p>HI98197 has GLP capability .<\/p>\n<p>HI98197 can transfer datas via USB to PC.<\/p>\n<p>&nbsp;<\/p>\n<p>The HI98197 is supplied with a specialized HI763123 four-ring conductivity probe that not only allows for a 0.001\u00a0\u03bcS\/cm resolution measurement but also has screw type threads for insertion into the HI605453 AISI 316 stainless steel flow cell.<\/p>\n<div id=\"attachment_4076\" style=\"width: 193px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4076\" loading=\"lazy\" class=\"size-full wp-image-4076\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98197.jpg\" alt=\"HI98197 Ultra Pure Water EC\/Resistivity Portable Meter\" width=\"183\" height=\"275\" \/><p id=\"caption-attachment-4076\" class=\"wp-caption-text\">HI98197 Ultra Pure Water EC\/Resistivity Portable Meter<\/p><\/div>\n<p>The HI763123 measure temperature and conductivity both.<\/p>\n<p>The HI763123 connection for connecting to meter is DIN.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>BELOW IS SOME hi98197 FEATURE LISTED:<\/strong><\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li><b><strong style=\"font-style: inherit;\">Expanded Ranges<\/strong><\/b><\/li>\n<li><b><strong style=\"font-style: inherit;\">USP &lt;645&gt;<\/strong><\/b> &#8211;<\/li>\n<li><b><strong style=\"font-style: inherit;\">5-Point Calibration<\/strong><\/b><\/li>\n<li><b><strong style=\"font-style: inherit;\">Temperature Compensation<\/strong><\/b><\/li>\n<li><b><strong style=\"font-style: inherit;\">TDS Conversion Factor<\/strong><\/b><\/li>\n<li><b><strong style=\"font-style: inherit;\">User Profiles<\/strong><\/b> &#8211;<\/li>\n<li><b><strong style=\"font-style: inherit;\">Logging<\/strong><\/b><\/li>\n<li><b><strong style=\"font-style: inherit;\">Good Laboratory Practice (GLP)<\/strong><\/b><\/li>\n<li><b><strong style=\"font-style: inherit;\">Contextual Help<\/strong><\/b><\/li>\n<li><b><strong style=\"font-style: inherit;\">Graphic LCD<\/strong><\/b><\/li>\n<li><b><strong style=\"font-style: inherit;\">Thermoformed Carrying Case<\/strong><\/b><\/li>\n<\/ul>\n<div id=\"attachment_4077\" style=\"width: 235px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4077\" loading=\"lazy\" class=\"size-full wp-image-4077\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98197-x.jpg\" alt=\"HI98197 Ultra Pure Water EC\/Resistivity Portable Meter\" width=\"225\" height=\"225\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98197-x.jpg 225w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98197-x-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98197-x-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98197-x-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98197-x-100x100.jpg 100w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><p id=\"caption-attachment-4077\" class=\"wp-caption-text\">HI98197 Ultra Pure Water EC\/Resistivity Portable Meter<\/p><\/div>\n<p>To know <strong><a href=\"http:\/\/www.hannainst.com\">HI98197<\/a> price<\/strong> or <strong>buy HI98197 Ultra Pure Water EC\/Resistivity Portable Meter<\/strong>\u00a0 ,please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong> <\/a>company.<\/p>\n<p><strong>HI98197 Ultra Pure Water EC\/Resistivity Portable Meter specification:<\/strong><\/p>\n<table id=\"zebra\" class=\"data-table\">\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">EC Range<\/th>\n<td class=\"data last\">0.000 to 9.999 \u03bcS\/cm; 10.00 to 99.99 \u03bcS\/cm; 100.0 to 999.9 \u03bcS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm (actual conductivity; temperature compensated to 400 mS\/cm)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">EC Resolution<\/th>\n<td class=\"data last\">0.001 \u03bcS\/cm; 0.01 \u03bcS\/cm; 0.1 \u03bcS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">EC Accuracy<\/th>\n<td class=\"data last\">\u00b11% of reading (\u00b10.01 \u03bcS\/cm or 1 digit, whichever is greater)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">EC Calibration<\/th>\n<td class=\"data last\">automatic up to five points with seven memorized standards (0.00 \u03bcS\/cm, 84.0 \u03bcS\/cm, 1.413 mS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">TDS Range<\/th>\n<td class=\"data last\">0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g\/L); 10.00 to 99.99 ppt (g\/L); 100.0 to 400.0 ppt (g\/L)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">TDS Resolution<\/th>\n<td class=\"data last\">0.01 ppm; 0.1 ppm; 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">TDS Accuracy<\/th>\n<td class=\"data last\">\u00b11% of reading (\u00b10.05 mg\/L (ppm) or 1 digit, whichever is greater)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">TDS Calibration<\/th>\n<td class=\"data last\">based on conductivity calibration<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Resistivity Range<\/th>\n<td class=\"data last\">1.0 to 99.9 \u03a9\u2022cm; 100 to 999 \u03a9\u2022cm; 1.00 to 9.99 K\u03a9\u2022cm; 10.0 to 99.9 K\u03a9\u2022cm; 100 to 999 K\u03a9\u2022cm; 1.00 to 9.99 M\u03a9\u2022cm; 10.0 to 100.0 M\u03a9\u2022cm<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Resistivity Resolution<\/th>\n<td class=\"data last\">0.1 \u03a9\u2022cm; 1 \u03a9\u2022cm; 0.01 K\u03a9\u2022cm; 0.1 K\u03a9\u2022cm; 1 K\u03a9\u2022cm; 0.01 M\u03a9\u2022cm; 0.1 M\u03a9\u2022cm<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Resistivity Accuracy<\/th>\n<td class=\"data last\">\u00b11% of reading (\u00b110 \u03a9 or 1 digit, whichever is greater)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Resistivity Calibration<\/th>\n<td class=\"data last\">based on conductivity calibration<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Salinity Range<\/th>\n<td class=\"data last\">% NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); natural seawater scale &#8211; UNESCO 1966: 0.00 to 80.00 (ppt)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Salinity Resolution<\/th>\n<td class=\"data last\">0.1%; 0.01<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Salinity Accuracy<\/th>\n<td class=\"data last\">\u00b11% of reading<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Salinity Calibration<\/th>\n<td class=\"data last\">max. one point only in % range (with HI7037 standard); use conductivity calibration for all other ranges<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Range<\/th>\n<td class=\"data last\">-20.0 to 120.0\u00b0C (-4.0 to 248.0\u00b0F)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Resolution<\/th>\n<td class=\"data last\">0.1\u00b0C (0.1\u00b0F)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Accuracy<\/th>\n<td class=\"data last\">\u00b10.2\u00b0C; \u00b10.4\u00b0F (excluding probe error)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Calibration<\/th>\n<td class=\"data last\">one or two points<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Compensation<\/th>\n<td class=\"data last\">noTC, Linear (-20 to 120 \u00b0C; -4 to 248\u00b0F), Non Linear &#8211; ISO\/DIN 7888 (-0 to 36 \u00b0C; 32 to 96.8\u00b0F)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Measurement Modes<\/th>\n<td class=\"data last\">autorange, autoend, lock and fixed range<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Reference Temperature<\/th>\n<td class=\"data last\">15\u00b0C, 20\u00b0C and 25\u00b0C<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Coefficient<\/th>\n<td class=\"data last\">0.00 to 10.00 %\/\u00b0C<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">TDS Factor<\/th>\n<td class=\"data last\">0.40 to 1.00<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Electrode\/Probe<\/th>\n<td class=\"data last\">HI763123 platinum, four ring conductivity\/TDS probe with internal temperature sensor and 1 m cable (included)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Log-on-demand<\/th>\n<td class=\"data last\">400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Memorized Profiles<\/th>\n<td class=\"data last\">up to 10<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">PC Connectivity<\/th>\n<td class=\"data last\">opto-isolated USB with optional HI 92000 software and micro USB cable<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Battery Type\/Life<\/th>\n<td class=\"data last\">1.5V AA batteries (4) \/ approximately 100 hours of continuous use (without backlight), 25 hours with backlight<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Auto-off<\/th>\n<td class=\"data last\">user selectable: 5, 10, 30, 60 min or can be disabled<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Environment<\/th>\n<td class=\"data last\">0 to 50\u00b0C (32 to 122\u00b0F); RH 100% (IP67)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Dimensions<\/th>\n<td class=\"data last\">185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4\u201d)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Weight<\/th>\n<td class=\"data last\">400 g (14.2 oz.)<\/td>\n<\/tr>\n<tr class=\"last odd\">\n<th class=\"label\">Ordering Information<\/th>\n<td class=\"data last\">HI98197 is supplied with HI763123 conductivity probe, HI605453 stainless steel flow cell, HI7033M 84 \u03bcS\/cm calibration solution (230 mL), HI7031M 1413 \u03bcS\/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instructions and rugged carrying case<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<h2>HI98197 Ultra Pure Water EC\/Resistivity Portable Meter<\/h2>\n<h4>Product information &#8220;HI98197 Ultra Pure Water EC\/Resistivity Waterproof Portable Meter&#8221;<\/h4>\n<p>The HI98197 is supplied with a specialized HI763123 four-ring conductivity probe that not only allows for a 0.001\u00a0\u03bcS\/cm resolution measurement but also has screw type threads for insertion into the HI605453 AISI 316 stainless steel flow cell.<\/p>\n","protected":false},"featured_media":4075,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4074"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4074"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4075"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4074"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}