{"id":4085,"date":"2020-11-23T16:34:03","date_gmt":"2020-11-23T17:34:03","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4085"},"modified":"2021-04-28T15:17:12","modified_gmt":"2021-04-28T15:17:12","slug":"hi98192-portable-ec-tds-resistivity-salinity-meter","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi98192-portable-ec-tds-resistivity-salinity-meter\/","title":{"rendered":"HI98192 Portable EC\/TDS\/Resistivity\/Salinity Meter"},"content":{"rendered":"<h2>HI98192 Portable EC\/TDS\/Resistivity\/Salinity Meter<\/h2>\n<h3>Product information &#8220;HI98192 Waterproof Portable EC\/TDS\/Resistivity\/Salinity Meter&#8221;<\/h3>\n<div id=\"attachment_4087\" style=\"width: 275px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4087\" loading=\"lazy\" class=\"size-full wp-image-4087\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98192.jpg\" alt=\"HI98192 Portable EC\/TDS\/Resistivity\/Salinity Meter\" width=\"265\" height=\"190\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98192.jpg 265w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98192-260x185.jpg 260w\" sizes=\"(max-width: 265px) 100vw, 265px\" \/><p id=\"caption-attachment-4087\" class=\"wp-caption-text\">HI98192 Portable EC\/TDS\/Resistivity\/Salinity Meter<\/p><\/div>\n<p>HI98192 is portable EC\/TDS\/ SALINITY meter made by HANNA.<\/p>\n<p>HI98192 measure the conductivity water from lowest range in dionized water to salty seawater.<\/p>\n<p>HI98192 can save data and via USB transfer datas to PC.<\/p>\n<p>HI98192 is supplied by HI763133 probe.<\/p>\n<p>HI763133 probe is four ring probe.<\/p>\n<p>HI763133 has DIN connector to connect to Meter.<\/p>\n<p>HI98192 measure conductivity from 0.000 \u03bcS\/cm to 1000 mS\/cm.<\/p>\n<p>HI98192 has GLP capability.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>some more details for HI98192 been listed as below :<\/strong><\/p>\n<p>&nbsp;<\/p>\n<ul>EC and TDS measurements are fully customizable and include:<\/ul>\n<ul>\n<li>Cell constant selection between 0.0 and 10.000<\/li>\n<li>Selection of linear or non-linear (natural water), or<\/li>\n<li>No temperature compensation<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>.The compact, durable HI720192 carry case is thermoformed to hold all necessary components for taking a field measurement, including: the meter, probe, beakers and conductivity standards.<\/p>\n<div id=\"attachment_4088\" style=\"width: 235px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4088\" loading=\"lazy\" class=\"size-full wp-image-4088\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98192-x.jpg\" alt=\"HI98192 Portable EC\/TDS\/Resistivity\/Salinity Meter\" width=\"225\" height=\"225\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98192-x.jpg 225w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98192-x-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98192-x-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98192-x-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98192-x-100x100.jpg 100w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><p id=\"caption-attachment-4088\" class=\"wp-caption-text\">HI98192 Portable EC\/TDS\/Resistivity\/Salinity Meter<\/p><\/div>\n<p>To know <strong><a href=\"http:\/\/www.hannainst.com\">HI98192<\/a> price<\/strong> or <strong>buy\u00a0 HI98192 Portable EC\/TDS\/Resistivity\/Salinity Meter<\/strong> ,please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/p>\n<p><strong>HI98192 Portable EC\/TDS\/Resistivity\/Salinity Meter specification:<\/strong><\/p>\n<table id=\"zebra\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\" \/>\n<col \/><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">EC Range<\/th>\n<td class=\"data last\">0.000 to 9.999 \u03bcS\/cm*; 10.00 to 99.99 \u03bcS\/cm; 100.0 to 999.9 \u03bcS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm (actual conductivity; temperature compensated to 400 mS\/cm)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">EC Resolution<\/th>\n<td class=\"data last\">0.001 \u03bcS\/cm; 0.01 \u03bcS\/cm; 0.1 \u03bcS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">EC Accuracy<\/th>\n<td class=\"data last\">\u00b11% of reading (\u00b10.01 \u03bcS\/cm or 1 digit, whichever is greater)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">EC Calibration<\/th>\n<td class=\"data last\">automatic up to five points with seven memorized standards (0.00 \u03bcS\/cm, 84.0 \u03bcS\/cm, 1.413 mS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">TDS Range<\/th>\n<td class=\"data last\">0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g\/L); 10.00 to 99.99 ppt (g\/L); 100.0 to 400.0 ppt (g\/L)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">TDS Resolution<\/th>\n<td class=\"data last\">0.01 ppm; 0.1 ppm; 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">TDS Accuracy<\/th>\n<td class=\"data last\">\u00b11% of reading (\u00b10.05 mg\/L (ppm) or 1 digit, whichever is greater)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Resistivity Range<\/th>\n<td class=\"data last\">1.0 to 99.9 \u03a9\u2022cm; 100 to 999 \u03a9\u2022cm; 1.00 to 9.99 K\u03a9\u2022cm; 10.0 to 99.9 K\u03a9\u2022cm; 100 to 999 K\u03a9\u2022cm; 1.00 to 9.99 M\u03a9\u2022cm; 10.0 to 100.0 M\u03a9\u2022cm<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Resistivity Resolution<\/th>\n<td class=\"data last\">0.1 \u03a9\u2022cm; 1 \u03a9\u2022cm; 0.01 K\u03a9\u2022cm; 0.1 K\u03a9\u2022cm; 1 K\u03a9\u2022cm; 0.01 M\u03a9\u2022cm; 0.1 M\u03a9\u2022cm*<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Resistivity Accuracy<\/th>\n<td class=\"data last\">\u00b11% of reading (\u00b110 \u03a9 or 1 digit, whichever is greater)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Salinity Range<\/th>\n<td class=\"data last\">% NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); natural seawater scale &#8211; UNESCO 1966: 0.00 to 80.00 (ppt)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Salinity Resolution<\/th>\n<td class=\"data last\">0.1%; 0.01<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Salinity Accuracy<\/th>\n<td class=\"data last\">\u00b11% of reading<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Salinity Calibration<\/th>\n<td class=\"data last\">max. one point only in % range (with HI7037 standard); use conductivity calibration for all other ranges<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Range<\/th>\n<td class=\"data last\">-20.0 to 120.0\u00b0C (-4.0 to 248.0\u00b0F)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Resolution<\/th>\n<td class=\"data last\">0.1\u00b0C (0.1\u00b0F)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Accuracy<\/th>\n<td class=\"data last\">\u00b10.2\u00b0C; \u00b10.4\u00b0F (excluding probe error)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Calibration<\/th>\n<td class=\"data last\">one or two points<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Compensation<\/th>\n<td class=\"data last\">noTC, Linear (-20 to 120 \u00b0C; -4 to 248\u00b0F), Non Linear &#8211; ISO\/DIN 7888 (-0 to 36 \u00b0C; 32 to 96.8\u00b0F)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Measurement Modes<\/th>\n<td class=\"data last\">autorange, autoend, lock and fixed range<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Reference Temperature<\/th>\n<td class=\"data last\">15\u00b0C, 20\u00b0C and 25\u00b0C<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Coefficient<\/th>\n<td class=\"data last\">0.00 to 10.00 %\/\u00b0C<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">TDS Factor<\/th>\n<td class=\"data last\">0.40 to 1.00<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Electrode\/Probe<\/th>\n<td class=\"data last\">HI763133, four ring conductivity\/TDS probe with internal temperature sensor and 4 m (13.2\u2019) cable (included)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Log-on-demand<\/th>\n<td class=\"data last\">400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Memorized Profiles<\/th>\n<td class=\"data last\">up to 10<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">PC Connectivity<\/th>\n<td class=\"data last\">opto-isolated USB with optional HI 92000 software and micro USB cable<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Battery Type\/Life<\/th>\n<td class=\"data last\">1.5V AA batteries (4) \/ approximately 100 hours of continuous use (without backlight), 25 hours with backlight<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Auto-off<\/th>\n<td class=\"data last\">user selectable: 5, 10, 30, 60 min or can be disabled<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Environment<\/th>\n<td class=\"data last\">0 to 50\u00b0C (32 to 122\u00b0F); RH 100% (IP67)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Dimensions<\/th>\n<td class=\"data last\">185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4\u201d)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Weight<\/th>\n<td class=\"data last\">400 g (14.2 oz.)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Ordering Information<\/th>\n<td class=\"data last\">HI98192 is supplied with HI763133 conductivity probe, HI7031M 1413 \u03bcS\/cm calibration solution (230 mL), HI7035M 111.8 mS\/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case.<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Notes<\/th>\n<td class=\"data last\">*The 0.001 \u03bcS\/cm EC range and 0.1 M\u03a9\u2022cm not available with supplied probe<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<h4>HI98192 Portable EC\/TDS\/Resistivity\/Salinity Meter<\/h4>\n<p>The HI98192 is supplied with the HI763133 four-ring conductivity probe with a built in temperature sensor. This technology allows for accurate readings that cover a complete range with a single sensor.<\/p>\n<p>The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763133 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.<\/p>\n","protected":false},"featured_media":4086,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4085"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4085"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4086"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4085"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}