{"id":4136,"date":"2020-11-24T16:29:21","date_gmt":"2020-11-24T17:29:21","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4136"},"modified":"2021-04-28T11:33:09","modified_gmt":"2021-04-28T11:33:09","slug":"hi5321-ec-tds-salinity-and-temperature","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi5321-ec-tds-salinity-and-temperature\/","title":{"rendered":"HI5321 EC \/ TDS \/ Salinity and Temperature"},"content":{"rendered":"<h2>HI5321 EC \/ TDS \/ Salinity and Temperature<\/h2>\n<div id=\"attachment_4138\" style=\"width: 235px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4138\" loading=\"lazy\" class=\"size-full wp-image-4138\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/5321.jpg\" alt=\"HI5321 EC \/ TDS \/ Salinity and Temperature\" width=\"225\" height=\"225\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/5321.jpg 225w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/5321-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/5321-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/5321-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/5321-100x100.jpg 100w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><p id=\"caption-attachment-4138\" class=\"wp-caption-text\">HI5321 EC \/ TDS \/ Salinity and Temperature<\/p><\/div>\n<h3>Product information &#8220;HI5321 RESEARCH GRADE EC \/ TDS \/ Salinity and Temperature with Color-Display&#8221;<\/h3>\n<p>HI5321 is EC \/ TDS \/ Salinity and Temperature bech top meter made from HANNA.<\/p>\n<p>HI5321 is professional bench top meter that is top choice for research institute.<\/p>\n<p>HI5321 is supplied with HI76312 four ring probe.<\/p>\n<p>HI5321 is supplied with the HI76312 four-ring conductivity probe.<\/p>\n<p>HI76312 probe measure conductivity in wide range from 0.000 \u03bcS\/cm to 1000.0 mS\/cm*.<\/p>\n<p>HI5321 has GLP capability.<\/p>\n<p>HI5321 \u00a0features a color graphic LCD with on-screen help, graphic, and custom color configurations.<\/p>\n<p>HI5321 is very top choice for pharmaceutical industry.<\/p>\n<p>HI5321 works with selectable loggin modes.automatic, manual and AutoHold logging<\/p>\n<p>&nbsp;<\/p>\n<p><strong>some HI5321 featurs been listed as below :<\/strong><\/p>\n<h4><\/h4>\n<ul>\n<li><b><strong style=\"font-style: inherit;\">Highly Customizable User Interface<\/strong><\/b> \u2013<\/li>\n<li><b><strong style=\"font-style: inherit;\">Color Graphic LCD <\/strong><\/b><\/li>\n<li><b><strong style=\"font-style: inherit;\">Capacitive Touch<\/strong><\/b>\u00a0<b><strong style=\"font-style: inherit;\">Four Ring Conductivity Probe<\/strong><\/b>\u00a0<b><strong style=\"font-style: inherit;\">Choice of Calibration<\/strong><\/b><\/li>\n<\/ul>\n<ul>\n<li><b><strong style=\"font-style: inherit;\">GLP Data<\/strong><\/b><\/li>\n<li><b><strong style=\"font-style: inherit;\">Data Logging<\/strong><\/b><\/li>\n<li><b><strong style=\"font-style: inherit;\">Data Transfer<\/strong><\/b><\/li>\n<li><b><strong style=\"font-style: inherit;\">Contextual Help<\/strong><\/b><\/li>\n<\/ul>\n<p>To know <strong><a href=\"http:\/\/www.hannainst.com\">HI5321<\/a> HANNA price<\/strong> or <strong>buy HI5321 EC \/ TDS \/ Salinity<\/strong> and Temperature , please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/p>\n<h3>\u00a0EC Specifications<\/h3>\n<p>EC RangeEC ResolutionEC Accuracy (@25\u00baC\/77\u00baF)EC Calibration<\/p>\n<table>\n<tbody>\n<tr>\n<td>0.000 to 9.999 \u03bcS\/cm, 10.00 to 99.99 \u03bcS\/cm, 100.0 to 999.9 \u03bcS\/cm, 1.000 to 9.999 mS\/cm, 10.00 to 99.99 mS\/cm, 100.0 to 1000.0 mS\/cm actual EC*<\/td>\n<\/tr>\n<tr>\n<td>0.001 \u03bcS\/cm, 0.01 \u03bcS\/cm, 0.1 \u03bcS\/cm, 1 \u03bcS\/cm, 0.001 mS\/cm, 0.01 mS\/cm, 0.1 mS\/cm<\/td>\n<\/tr>\n<tr>\n<td>\u00b11% of reading (\u00b10.01 \u03bcS\/cm)<\/td>\n<\/tr>\n<tr>\n<td>automatic standard recognition (0.000 \u03bcS\/cm, 84.00 \u03bcS\/cm, 1.413 mS\/cm, 5.000 mS\/cm, 12.88 mS\/cm, 80.00 mS\/cm, 111.8 mS\/cm) or user standard; single point or multi-point calibration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u00a0TDS Specifications<\/h3>\n<p>TDS RangeTDS ResolutionTDS Accuracy (@25\u00baC\/77\u00baF)<\/p>\n<table>\n<tbody>\n<tr>\n<td>0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 ppt, 10.00 to 99.99 ppt, 100.0 to 400.0 ppt actual TDS* (with 1.00 factor)<\/td>\n<\/tr>\n<tr>\n<td>0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt<\/td>\n<\/tr>\n<tr>\n<td>\u00b11% of reading (\u00b10.01 ppm)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Resistivity Specifications<\/h3>\n<p>Resistivity RangeResistivity ResolutionResistivity Accuracy<\/p>\n<table>\n<tbody>\n<tr>\n<td>1.0 to 99.9 \u03a9\u2022cm; 100 to 999 \u03a9\u2022cm; 1.00 to 9.99 K\u03a9\u2022cm; 10.0 to 99.9 K\u03a9\u2022cm; 100 to 999 K\u03a9\u2022cm; 1.00 to 9.99 M\u03a9\u2022cm; 10.0 to 100.0 M\u03a9\u2022cm<\/td>\n<\/tr>\n<tr>\n<td>0.1 \u03a9\u2022cm; 1 \u03a9\u2022cm; 0.01 K\u03a9\u2022cm; 0.1 K\u03a9\u2022cm; 1 K\u03a9\u2022cm; 0.01 M\u03a9\u2022cm; 0.1 M\u03a9\u2022cm*<\/td>\n<\/tr>\n<tr>\n<td>\u00b12% of reading (\u00b11 \u03a9\u2022cm)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Salinity Specifications<\/h3>\n<p>Salinity RangeSalinity ResolutionSalinity Accuracy (@25\u00baC\/77\u00baF)Salinity Calibration<\/p>\n<table>\n<tbody>\n<tr>\n<td>practical scale: 0.00 to 42.00 psu; natural seawater scale: 0.00 to 80.00 ppt; percent scale: 0.0 to 400.0%<\/td>\n<\/tr>\n<tr>\n<td>0.01 for practical scale\/natural seawater scale; 0.1% for percent scale<\/td>\n<\/tr>\n<tr>\n<td>\u00b11% of reading<\/td>\n<\/tr>\n<tr>\n<td>percent scale\u2014one-point (with HI7037 standard)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Temperature Specifications<\/h3>\n<p>Temperature RangeTemperature ResolutionTemperature AccuracyTemperature CompensationTemperature CoefficientReference Temperature<\/p>\n<table>\n<tbody>\n<tr>\n<td>-20.0 to 120.0 \u00baC**; -4.0 to 248.0 \u00baF**; 253.15 to 393.15 K**<\/td>\n<\/tr>\n<tr>\n<td>0.1 \u00b0C, 0.1 \u00b0F, 0.1 K<\/td>\n<\/tr>\n<tr>\n<td>\u00b10.2 \u00b0C; \u00b10.4 \u00b0F; \u00b10.2 K (without probe)<\/td>\n<\/tr>\n<tr>\n<td>disabled, linear and non-linear (natural water)<\/td>\n<\/tr>\n<tr>\n<td>0.00 to 10.00 %\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>5.0 to 30.0 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Additional Specifications<\/h3>\n<p>Cell ConstantCell TypeElectrode\/ProbeProfilesUSP \u27e8645\u27e9 CompliantGLPLoggingDisplayConnectivityEnvironmentPower SupplyDimensionsWeightOrdering InformationNotes<\/p>\n<table>\n<tbody>\n<tr>\n<td>0.0500 to 200.00<\/td>\n<\/tr>\n<tr>\n<td>4 cells<\/td>\n<\/tr>\n<tr>\n<td>HI76312 platinum, four-ring EC\/TDS probe with and 1 m (3.3\u2019) cable (included)<\/td>\n<\/tr>\n<tr>\n<td>up to 10, 5 each channel<\/td>\n<\/tr>\n<tr>\n<td>yes<\/td>\n<\/tr>\n<tr>\n<td>cell constant, reference temperature, temperature coefficient, calibration points, calibration time stamp, and probe offset for conductivity<\/td>\n<\/tr>\n<tr>\n<td>record: 100,000 data point storage, up to 100 lots with max. 50,000 records\/lot; interval: settable between 1 second and max log time of 180 minutes; type: automatic, manual, AutoHOLD; additional: 200 records USP<\/td>\n<\/tr>\n<tr>\n<td>color graphic LCD with on-screen help, graphing, and custom color configuration<\/td>\n<\/tr>\n<tr>\n<td>USB<\/td>\n<\/tr>\n<tr>\n<td>0 to 50\u00b0C (32 to 122\u00b0F; 273 to 323 K), RH max 95% non-condensing<\/td>\n<\/tr>\n<tr>\n<td>12 VDC adapter (included)<\/td>\n<\/tr>\n<tr>\n<td>160 x 231 x 94 mm (6.3 x 9.1 x 3.7\u201d)<\/td>\n<\/tr>\n<tr>\n<td>1.2 kg (2.64 lbs.)<\/td>\n<\/tr>\n<tr>\n<td>HI5321 is supplied with HI76312 conductivity probe, HI76404W electrode holder, 12 VDC power adapter and instructions<\/td>\n<\/tr>\n<tr>\n<td>*Uncompensated conductivity (or TDS) is the conductivity (or TDS) value without temperature compensation. **Reduced to actual probe limits<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>HI5321 EC \/ TDS \/ Salinity and Temperature<\/p>\n[caption id=\"attachment_4138\" align=\"aligncenter\" width=\"225\"]<img loading=\"lazy\" class=\"size-full wp-image-4138\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/5321.jpg\" alt=\"HI5321 EC \/ TDS \/ Salinity and Temperature\" width=\"225\" height=\"225\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/5321.jpg 225w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/5321-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/5321-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/5321-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/5321-100x100.jpg 100w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/> HI5321 EC \/ TDS \/ Salinity and Temperature[\/caption]\n<h3>Product information &#8220;HI5321 RESEARCH GRADE EC \/ TDS \/ Salinity and Temperature with Color-Display&#8221;<\/h3>\n<h4>HI5321 EC \/ TDS \/ Salinity and Temperature Details<\/h4>\n<p>The HI5321 is an advanced research grade benchtop EC\/TDS\/Salinity\/Resistivity meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity.<\/p>\n","protected":false},"featured_media":4137,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4136"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4136"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4137"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4136"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}