{"id":4178,"date":"2020-11-25T09:29:33","date_gmt":"2020-11-25T10:29:33","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4178"},"modified":"2025-10-03T03:24:13","modified_gmt":"2025-10-03T03:24:13","slug":"hi98193-dissolved-oxygen-and-bod-meter","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi98193-dissolved-oxygen-and-bod-meter\/","title":{"rendered":"HI98193 Dissolved Oxygen and BOD Meter"},"content":{"rendered":"<h2>HI98193 Dissolved Oxygen and BOD Meter<\/h2>\n<div id=\"attachment_4181\" style=\"width: 235px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4181\" loading=\"lazy\" class=\"size-full wp-image-4181\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193.jpg\" alt=\"HI98193 Dissolved Oxygen and BOD Meter\" width=\"225\" height=\"225\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193.jpg 225w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193-100x100.jpg 100w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><p id=\"caption-attachment-4181\" class=\"wp-caption-text\">HI98193 Dissolved Oxygen and BOD Meter<\/p><\/div>\n<h3>Product information &#8220;<a href=\"http:\/\/www.hannainst.com\">HI98193<\/a> Waterproof Portable Dissolved Oxygen and BOD Meter (4 or 10m cable)&#8221;<\/h3>\n<p dir=\"ltr\">HI98193 is portable and water proof oxygen dissolved meter produced by HANNA.<\/p>\n<p dir=\"ltr\">HI98193 is auto calibration DO meter .<\/p>\n<p dir=\"ltr\">HI98193 is supplied in hard case to carry safe to every where by user.<\/p>\n<p dir=\"ltr\">HI98193 carry case is HI760193.<\/p>\n<p dir=\"ltr\">HI98193 is supplied by HI764073 probe.<\/p>\n<p dir=\"ltr\">HI764073 probe is Polarographic prob .<\/p>\n<p dir=\"ltr\">HI764073 can measure DO and Temperature both.<\/p>\n<p dir=\"ltr\">HI98193 can measure BOD and DO .<\/p>\n<p dir=\"ltr\">HI98193 portable DO meter can measure the ranges of up to 50 ppm and 600% saturation.<\/p>\n<p dir=\"ltr\">HI98193 can connect to PC and transfer saved data via USB port.<\/p>\n<p dir=\"ltr\">HI98193 has GLP capability .<\/p>\n<p dir=\"ltr\">GLP data are contain date, time, pressure, calibrated value, temperature and salinity value of the last calibration.<\/p>\n<p dir=\"ltr\">HI98193 has wide LCD with backlight and user is able to see the reading results in each angle.<\/p>\n<p dir=\"ltr\">\n<p dir=\"ltr\">inside HI760193 IS the meter and electrode, beakers, buffer solutions, cleaning solutions and storage solutions.<\/p>\n<div id=\"attachment_4182\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4182\" loading=\"lazy\" class=\"size-full wp-image-4182\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193-x.jpg\" alt=\"HI98193 Dissolved Oxygen and BOD Meter\" width=\"300\" height=\"168\" \/><p id=\"caption-attachment-4182\" class=\"wp-caption-text\">HI98193 Dissolved Oxygen and BOD Meter<\/p><\/div>\n<p>To know <strong><a href=\"http:\/\/www.hannainst.com\">HI98193 HANNA<\/a> price<\/strong> or <strong>buy HI98193 Dissolved Oxygen and BOD Meter<\/strong> , please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/p>\n<p><strong>HI98193 Dissolved Oxygen and BOD Meter specification :<\/strong><\/p>\n<table id=\"zebra\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\" \/>\n<col \/><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">DO Range<\/th>\n<td class=\"data last\">0.00 to 50.00 ppm (mg\/L); 0.0 to 600.0% saturation<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">DO Resolution<\/th>\n<td class=\"data last\">0.01 ppm (mg\/L); 0.1% saturation<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">DO Accuracy<\/th>\n<td class=\"data last\">\u00b11.5% of reading \u00b11 digit<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">DO Calibration<\/th>\n<td class=\"data last\">automatic one or two point at 100% saturation (8.26 mg\/L) and 0% saturation (0 mg\/L).<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Atmospheric Pressure Range<\/th>\n<td class=\"data last\">450 to 850 mmHg<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Atmospheric Pressure Resolution<\/th>\n<td class=\"data last\">1 mmHg<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Atmospheric Pressure Accuracy<\/th>\n<td class=\"data last\">\u00b1 3 mmHg within \u00b115% from the calibration point<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Atmospheric Pressure Calibration<\/th>\n<td class=\"data last\">one point at any in range pressure value<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Range<\/th>\n<td class=\"data last\">-20.0 to 120.0\u00b0C (-4.0 to 248.0\u00b0F)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Resolution<\/th>\n<td class=\"data last\">0.1\u00b0C (0.1\u00b0F)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Accuracy<\/th>\n<td class=\"data last\">\u00b10.2\u00b0C; \u00b10.4\u00b0F (excluding probe error)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Calibration<\/th>\n<td class=\"data last\">one or two point at any in range temperature value<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Compensation<\/th>\n<td class=\"data last\">automatic from 0 to 50\u00b0C (32 to 122\u00b0F)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Measurement Modes<\/th>\n<td class=\"data last\">direct DO; BOD (biochemical oxygen demand); OUR (oxygen uptake rate); SOUR (specific oxygen uptake rate)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Barometric Compensation<\/th>\n<td class=\"data last\">automatic from 450 to 850 mmHg<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Salinity Compenstaion<\/th>\n<td class=\"data last\">automatic from 0 to 70 g\/L<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Electrode\/Probe<\/th>\n<td class=\"data last\">HI764073 polarographic DO probe with protective sleeve, internal temperature sensor, DIN connector and 4m (13\u2019)\u00a0or 10m (32&#8242;) cable option will be provided.<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Log-on-demand<\/th>\n<td class=\"data last\">up to 400 samples<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">PC Connectivity<\/th>\n<td class=\"data last\">opto-isolated USB with optional HI 92000 software and micro USB cable<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Battery Type\/Life<\/th>\n<td class=\"data last\">1.5V AA batteries (4) \/ approximately 200 hours of continuous use without backlight (50 hours with backlight)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Auto-off<\/th>\n<td class=\"data last\">user selectable: 5, 10, 30, 60 min or can be disabled<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Environment<\/th>\n<td class=\"data last\">0 to 50\u00b0C (32 to 122\u00b0F); RH 100% (IP67)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Dimensions<\/th>\n<td class=\"data last\">185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4\u201d)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Weight<\/th>\n<td class=\"data last\">400 g (14.2 oz.)<\/td>\n<\/tr>\n<tr class=\"last odd\">\n<th class=\"label\">Ordering Information<\/th>\n<td class=\"data last\">HI98193 is supplied with HI764073 DO probe, preformed PTFE membrane cap (2), HI7041S electrolyte solution (30 mL), HI7040 bicomponent zero oxygen solution, 100 mL plastic beakers (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, instrument quality certificate and HI760193 rugged carrying case.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<h2>HI98193 Dissolved Oxygen and BOD Meter<\/h2>\n<p>&nbsp;<\/p>\n[caption id=\"attachment_4181\" align=\"aligncenter\" width=\"225\"]<img loading=\"lazy\" class=\"size-full wp-image-4181\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193.jpg\" alt=\"HI98193 Dissolved Oxygen and BOD Meter\" width=\"225\" height=\"225\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193.jpg 225w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98193-100x100.jpg 100w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/> HI98193 Dissolved Oxygen and BOD Meter[\/caption]\n<h3>Product information &#8220;HI98193 Waterproof Portable Dissolved Oxygen and BOD Meter (4 or 10m cable)&#8221;<\/h3>\n<p dir=\"ltr\">For the measurement of DO the HI98193 is supplied with the HI764073 polarographic dissolved oxygen probe. This probe uses preformed PTFE membrane caps that are field replaceable. The probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connect that is also easy to remove.<\/p>\n","protected":false},"featured_media":4179,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4178"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4178"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4179"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4178"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}