{"id":4241,"date":"2020-11-28T08:11:53","date_gmt":"2020-11-28T09:11:53","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4241"},"modified":"2021-04-27T17:03:22","modified_gmt":"2021-04-27T17:03:22","slug":"hi98195-multiparameter","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi98195-multiparameter\/","title":{"rendered":"HI98195 Multiparameter"},"content":{"rendered":"<h2>HI98195 Multiparameter<\/h2>\n<h3>HI98195 Multiparameter &#8211; pH \/ ORP \/ EC \/ TDS \/ Salinity \/ Temp &#8211; with Complete Set<\/h3>\n<div id=\"attachment_4242\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4242\" loading=\"lazy\" class=\"size-full wp-image-4242\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98195-2-300x300-1.jpg\" alt=\"HI98195 Multiparameter\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98195-2-300x300-1.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98195-2-300x300-1-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98195-2-300x300-1-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98195-2-300x300-1-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98195-2-300x300-1-100x100.jpg 100w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-4242\" class=\"wp-caption-text\">HI98195 Multiparameter<\/p><\/div>\n<p>&nbsp;<\/p>\n<h3>Product information &#8220;HI98195 Multiparameter &#8211; pH \/ ORP \/ EC \/ TDS \/ Salinity \/ Temp &#8211; with Complete Set&#8221;<\/h3>\n<p>HI98195 is a multiparameter HANNA device that measure PH\/EC\/TDS\/SALINITY \/TEMP.<\/p>\n<p>HI98195 is a Rugged, waterproof instrument.<\/p>\n<p>HI98195 is very easy to use, the HI 98195 is the ideal meters\u00a0 for field measurements of lakes, rivers and seas.<\/p>\n<p>The HI 98195 is suit multi parameter to measure the paramets of water and control water quality parameters such as pH, ORP, conductivity, temperature, resistivity, TDS, salinity, and\u00a0 seawater specific gravity.<\/p>\n<p>HI98195 such as other HI9819X series has GLP feature.<\/p>\n<p>&nbsp;<\/p>\n<p>To know <strong><a href=\"http:\/\/www.hannainst.com\">HI98195<\/a> HANNA price<\/strong> or buy <strong>HI98195 Multiparameter ,please <\/strong>contact<a href=\"http:\/\/www.sa-aria.com\"><strong> Setare Arsh Aria <\/strong><\/a>company.<\/p>\n<p><strong>HI98195 Multiparameter Specification :<\/strong><\/p>\n<div>\n<table id=\"zebra\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\" \/>\n<col \/><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">pH Range<\/th>\n<td class=\"data last\">0.00 to 14.00 pH<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">pH Resolution<\/th>\n<td class=\"data last\">0.01 pH<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">pH Accuracy<\/th>\n<td class=\"data last\">\u00b10.02 pH<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">pH Calibration<\/th>\n<td class=\"data last\">automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">mV Range<\/th>\n<td class=\"data last\">\u00b1600.0 mV<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">mV Resolution<\/th>\n<td class=\"data last\">0.1 mV<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">mV Accuracy<\/th>\n<td class=\"data last\">\u00b10.5 mV<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">ORP Range<\/th>\n<td class=\"data last\">\u00b12000.0 mV<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">ORP Resolution<\/th>\n<td class=\"data last\">0.1 mV<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">ORP Accuracy<\/th>\n<td class=\"data last\">\u00b11.0 mV<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">ORP Calibration<\/th>\n<td class=\"data last\">automatic at one custom point (relative mV)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">EC Range<\/th>\n<td class=\"data last\">0 to 9999 \u00b5S\/cm; 0.000 to 200.0 mS\/cm (absolute EC up to 400.0 mS\/cm)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">EC Resolution<\/th>\n<td class=\"data last\">auto-ranging: 1 \u00b5S\/cm from 0 to 9999 \u00b5S\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm; auto-ranging (fixed mS\/cm): 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 from 100.0 to 400.0 mS\/cm ; manual: 1 \u00b5S\/cm; 0.001 mS\/cm; 0.01<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">EC Accuracy<\/th>\n<td class=\"data last\">\u00b11% of reading or \u00b11 \u00b5S\/cm whichever is greater<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">EC Calibration<\/th>\n<td class=\"data last\">automatic single point, with six standard solutions (84 \u00b5S\/cm, 1413 \u00b5S\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">TDS Range<\/th>\n<td class=\"data last\">0 to 9999 ppm (mg\/L); 0.000 to 400.0 ppt (g\/L) (maximum value depends on TDS factor)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">TDS Resolution<\/th>\n<td class=\"data last\">manual: 1 ppm (mg\/L); 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L); auto-ranging: 1 ppm (mg\/L) from 0 to 9999 ppm (mg\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L); auto-ranging (fixed ppt):<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">TDS Accuracy<\/th>\n<td class=\"data last\">\u00b11% of reading or \u00b11 ppm (mg\/L), whichever is greater<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">TDS Calibration<\/th>\n<td class=\"data last\">based on conductivity calibration<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Resistivity Range<\/th>\n<td class=\"data last\">0 to 999999 \u03a9\u2022cm; 0 to 1000.0 k\u03a9\u2022cm; 0 to 1.0000 M\u03a9\u2022cm<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Resistivity Resolution<\/th>\n<td class=\"data last\">dependent on resistivity reading<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Resistivity Calibration<\/th>\n<td class=\"data last\">based on conductivity calibration<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Salinity Range<\/th>\n<td class=\"data last\">0.00 to 70.00 PSU<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Salinity Resolution<\/th>\n<td class=\"data last\">0.01 PSU<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Salinity Accuracy<\/th>\n<td class=\"data last\">\u00b12% of reading or \u00b10.01 PSU whichever is greater<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Salinity Calibration<\/th>\n<td class=\"data last\">based on conductivity calibration<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Seawater \u03c3 Range<\/th>\n<td class=\"data last\">0.0 to 50.0 \u03c3t, \u03c3\u2080, \u03c3\u2081\u2085<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Seawater \u03c3 Resolution<\/th>\n<td class=\"data last\">0.1 \u03c3t, \u03c3\u2080, \u03c3\u2081\u2085<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Seawater \u03c3 Accuracy<\/th>\n<td class=\"data last\">\u00b11 \u03c3t, \u03c3\u2080, \u03c3\u2081\u2085<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Seawater \u03c3 Calibration<\/th>\n<td class=\"data last\">based on conductivity calibration<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Atmospheric Pressure Range<\/th>\n<td class=\"data last\">450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Atmospheric Pressure Resolution<\/th>\n<td class=\"data last\">0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Atmospheric Pressure Accuracy<\/th>\n<td class=\"data last\">\u00b13 mm Hg within \u00b115\u00b0C from the temperature during calibration<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Atmospheric Pressure Calibration<\/th>\n<td class=\"data last\">automatic at one custom point<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Range<\/th>\n<td class=\"data last\">-5.00 to 55.00 \u00b0C, 23.00 to 131.00 \u00b0F, 268.15 to 328.15 K<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Resolution<\/th>\n<td class=\"data last\">0.01 K, 0.01 \u00b0C, 0.01 \u00b0F<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Accuracy<\/th>\n<td class=\"data last\">\u00b10.15 \u00b0C; \u00b10.27 \u00b0F; \u00b10.15 K<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Calibration<\/th>\n<td class=\"data last\">automatic at one custom point<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Compensation<\/th>\n<td class=\"data last\">automatic from -5 to 55 \u00b0C (23 to 131 \u00b0F)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Logging Memory<\/th>\n<td class=\"data last\">45,000 records (continuous logging or log-on-demand of all parameters)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Logging Interval<\/th>\n<td class=\"data last\">one second to three hours<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">PC Connectivity<\/th>\n<td class=\"data last\">USB to PC with HI9298194 Hanna software installed<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Battery Type\/Life<\/th>\n<td class=\"data last\">1.5V AA batteries (4) \/ approximately 360 hours of continuous use without backlight (50 hours with backlight)\u00a0<strong>With probe connected, approximately 104 hours of continuous use without backlight.<\/strong><\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Environment<\/th>\n<td class=\"data last\">0 to 50\u00b0C (32 to 122\u00b0F); RH 100% (IP67)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Dimensions<\/th>\n<td class=\"data last\">185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4\u201d)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Weight<\/th>\n<td class=\"data last\">400 g (14.2 oz.)<\/td>\n<\/tr>\n<tr class=\"last odd\">\n<th class=\"label\">Ordering Information<\/th>\n<td class=\"data last\">HI98195 is supplied with HI7698195 probe, HI7698194-1 pH\/ORP sensor, HI7698194-3 EC sensor, HI 76981952 Probe maintenance kit (O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h3>HI98195 Multiparameter<\/h3>\n<h3>HI98195 Multiparameter &#8211; pH \/ ORP \/ EC \/ TDS \/ Salinity \/ Temp &#8211; with Complete Set<\/h3>\n[caption id=\"attachment_4242\" align=\"aligncenter\" width=\"300\"]<img loading=\"lazy\" class=\"size-full wp-image-4242\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98195-2-300x300-1.jpg\" alt=\"HI98195 Multiparameter\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98195-2-300x300-1.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98195-2-300x300-1-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98195-2-300x300-1-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98195-2-300x300-1-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98195-2-300x300-1-100x100.jpg 100w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> HI98195 Multiparameter[\/caption]\n<p>&nbsp;<\/p>\n<h3>Product information &#8220;HI98195 Multiparameter &#8211; pH \/ ORP \/ EC \/ TDS \/ Salinity \/ Temp &#8211; with Complete Set&#8221;<\/h3>\n<p>Rugged, waterproof and easy to use, the HI 98195 is the ideal meters\u00a0 for field measurements of lakes, rivers and seas.<\/p>\n<p>The HI 98195 can\u00a0 measure water quality parameters such as pH, ORP, conductivity, temperature, resistivity, TDS, salinity, and\u00a0 seawater specific gravity.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":4242,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4241"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4241"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4242"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4241"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}