{"id":4248,"date":"2020-11-28T08:28:44","date_gmt":"2020-11-28T09:28:44","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4248"},"modified":"2021-04-27T16:54:42","modified_gmt":"2021-04-27T16:54:42","slug":"hi98196-multiparameter","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi98196-multiparameter\/","title":{"rendered":"HI98196 Multiparameter"},"content":{"rendered":"<h2>HI98196 Multiparameter<\/h2>\n<h3>HI98196 Multiparameter &#8211; pH \/ ORP \/ DO \/ Temp &#8211; 4m Cable Complete Set<\/h3>\n<div id=\"attachment_4250\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4250\" loading=\"lazy\" class=\"size-full wp-image-4250\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98196-300x300-2.jpg\" alt=\"HI98196 Multiparameter\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98196-300x300-2.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98196-300x300-2-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98196-300x300-2-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98196-300x300-2-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98196-300x300-2-100x100.jpg 100w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-4250\" class=\"wp-caption-text\">HI98196 Multiparameter<\/p><\/div>\n<p>&nbsp;<\/p>\n<h4>Product information &#8220;HI98196 Multiparameter &#8211; pH \/ ORP \/ DO \/ Temp &#8211; 4m Cable Complete Set&#8221;<\/h4>\n<p>HI98196 is a portable device of HANNA that measure pH , ORP , DO,Temp.<\/p>\n<p>HI98196 is suit multi parameter for measuring these parameters in lakes , rivers and sea.<\/p>\n<p>HI98196 is Rugged, waterproof and easy to use.<\/p>\n<p>HI98196 has GLP capability .<\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>To know <strong>HI98196 <a href=\"http:\/\/www.hannainst.com\">HANNA<\/a> price or buy HI98196 multiparameter<\/strong> , please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/p>\n<p>&nbsp;<\/p>\n<div><strong>technical Specification of HI98196 :<\/strong><\/div>\n<table id=\"zebra\" class=\"data-table\">\n<colgroup>\n<col width=\"25%\" \/>\n<col \/><\/colgroup>\n<tbody>\n<tr class=\"first odd\">\n<th class=\"label\">pH Range<\/th>\n<td class=\"data last\">0.00 to 14.00 pH<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">pH Resolution<\/th>\n<td class=\"data last\">0.01 pH<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">pH Accuracy<\/th>\n<td class=\"data last\">\u00b10.02 pH<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">pH Calibration<\/th>\n<td class=\"data last\">automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">mV Range<\/th>\n<td class=\"data last\">\u00b1600.0 mV<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">mV Resolution<\/th>\n<td class=\"data last\">0.1 mV<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">mV Accuracy<\/th>\n<td class=\"data last\">\u00b10.5 mV<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">ORP Range<\/th>\n<td class=\"data last\">\u00b12000 mV<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">ORP Resolution<\/th>\n<td class=\"data last\">0.1 mV<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">ORP Accuracy<\/th>\n<td class=\"data last\">\u00b11.0 mV<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">ORP Calibration<\/th>\n<td class=\"data last\">automatic at one custom point (relative mV)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">DO Range<\/th>\n<td class=\"data last\">0.0 to 500.0%; 0.00 to 50.00 ppm (mg\/L)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">DO Resolution<\/th>\n<td class=\"data last\">0.1%; 0.01 ppm (mg\/L)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">DO Accuracy<\/th>\n<td class=\"data last\">0.0 to 300.0% saturation: \u00b11.5% of reading or \u00b11.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg\/L): \u00b11.5% of reading or \u00b10.10 ppm (mg\/L), whichever is greater, 30.00 ppm (mg\/L) to 50.00 ppm (mg\/L): \u00b13% of reading, 300.0 to 500.0% saturation: \u00b13% of reading<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">DO Calibration<\/th>\n<td class=\"data last\">automatic one or two point at 100% saturation (8.26 mg\/L) and 0% saturation (0 mg\/L).<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Atmospheric Pressure Range<\/th>\n<td class=\"data last\">450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Atmospheric Pressure Resolution<\/th>\n<td class=\"data last\">0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Atmospheric Pressure Accuracy<\/th>\n<td class=\"data last\">\u00b13 mm Hg within \u00b115\u00b0C from the temperature during calibration<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Atmospheric Pressure Calibration<\/th>\n<td class=\"data last\">automatic at one custom point<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Range<\/th>\n<td class=\"data last\">-5.00 to 55.00 \u00b0C, 23.00 to 131.00 \u00b0F, 268.15 to 328.15 K<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Resolution<\/th>\n<td class=\"data last\">0.01 K, 0.01 \u00b0C, 0.01 \u00b0F<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Accuracy<\/th>\n<td class=\"data last\">\u00b10.15 \u00b0C; \u00b10.27 \u00b0F; \u00b10.15 K<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Temperature Calibration<\/th>\n<td class=\"data last\">automatic at one custom point<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Temperature Compensation<\/th>\n<td class=\"data last\">automatic from -5 to 55 \u00b0C (23 to 131 \u00b0F)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Logging Memory<\/th>\n<td class=\"data last\">45,000 records (continuous logging or log-on-demand of all parameters)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Logging Interval<\/th>\n<td class=\"data last\">one second to three hours<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">PC Connectivity<\/th>\n<td class=\"data last\">USB to PC with HI9298194 Hanna software installed<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Battery Type\/Life<\/th>\n<td class=\"data last\">1.5V AA batteries (4) \/ approximately 360 hours of continuous use without backlight (50 hours with backlight)\u00a0<strong>With probe connected, approximately 104 hours of continuous use without backlight.<\/strong><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Environment<\/th>\n<td class=\"data last\">0 to 50\u00b0C (32 to 122\u00b0F); RH 100% (IP67)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th class=\"label\">Dimensions<\/th>\n<td class=\"data last\">185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4\u201d)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th class=\"label\">Weight<\/th>\n<td class=\"data last\">400 g (14.2 oz.)<\/td>\n<\/tr>\n<tr class=\"last even\">\n<th class=\"label\">Ordering Information<\/th>\n<td class=\"data last\">HI98196 is supplied with HI7698196 probe, HI7698194-1 pH\/ORP sensor, HI7698194-2 DO sensor, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<h3>HI98196 Multiparameter &#8211; pH \/ ORP \/ DO \/ Temp &#8211; 4m Cable Complete Set<\/h3>\n[caption id=\"attachment_4250\" align=\"aligncenter\" width=\"300\"]<img loading=\"lazy\" class=\"size-full wp-image-4250\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98196-300x300-2.jpg\" alt=\"HI98196 Multiparameter\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98196-300x300-2.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98196-300x300-2-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98196-300x300-2-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98196-300x300-2-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI98196-300x300-2-100x100.jpg 100w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> HI98196 Multiparameter[\/caption]\n<p>&nbsp;<\/p>\n<h4>Product information &#8220;HI98196 Multiparameter &#8211; pH \/ ORP \/ DO \/ Temp &#8211; 4m Cable Complete Set&#8221;<\/h4>\n<p>Rugged, waterproof and easy to use, the HI 98196 is the ideal meters\u00a0 for field measurements of lakes, rivers and seas.<\/p>\n<p>The HI 98196 can\u00a0 measure water quality parameters such as pH, ORP,\u00a0temperature and\u00a0dissolved oxygen concentration. Atmospheric pressure is measured for DO\u00a0 compensation.<\/p>\n","protected":false},"featured_media":4249,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4248"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4248"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4249"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4248"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}