{"id":4256,"date":"2020-11-28T08:54:33","date_gmt":"2020-11-28T09:54:33","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4256"},"modified":"2021-04-27T16:29:30","modified_gmt":"2021-04-27T16:29:30","slug":"hi98199-multiparameter","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi98199-multiparameter\/","title":{"rendered":"HI98199 Multiparameter"},"content":{"rendered":"<h2>HI98199 Multiparameter<\/h2>\n<div id=\"attachment_4258\" style=\"width: 277px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4258\" loading=\"lazy\" class=\"size-medium wp-image-4258\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98199_with_EC_2020_with_probe-1-267x300.jpg\" alt=\"HI98199 Multiparameter\" width=\"267\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98199_with_EC_2020_with_probe-1-267x300.jpg 267w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98199_with_EC_2020_with_probe-1-768x862.jpg 768w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98199_with_EC_2020_with_probe-1-628x705.jpg 628w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98199_with_EC_2020_with_probe-1-600x674.jpg 600w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/98199_with_EC_2020_with_probe-1.jpg 832w\" sizes=\"(max-width: 267px) 100vw, 267px\" \/><p id=\"caption-attachment-4258\" class=\"wp-caption-text\">HI98199 Multiparameter<\/p><\/div>\n<section>\n<article>\n<div class=\"section-row\">\n<div id=\"extended-description-tabs\" class=\"extended-description\">\n<div class=\"row\">\n<div id=\"description\" class=\"section-row section 1\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<h3>pH electrode included<\/h3>\n<p>HI98199 is portable multiparameter that only include pH and temperature electrode .<\/p>\n<p>HI98199 can supply EC\/TDS \/DO with seperate electrodes .<\/p>\n<p>The model of PH electrode is HI829113 digital pH probe.<\/p>\n<p><strong>Some details for HI98199 been listed as below:<\/strong><\/p>\n<ul>\n<li>Up to a three-point calibration with five standard buffers and one custom buffer available<\/li>\n<li>pH in mV option is useful for diagnostics<\/li>\n<li>GLP data Offset, slope, date, time and buffers used<\/li>\n<li>Automatically temperature compensated readings<\/li>\n<li>pH sensor Gel filled and maintenance free<\/li>\n<li>Double junction for reduced contamination of reference cell<\/li>\n<\/ul>\n<h3>some other charactristics of HI98199<\/h3>\n<ul>\n<li>Temperature compensation<\/li>\n<li><span style=\"font-size: 20px;\">Backlit Graphic LCD Display<\/span><\/li>\n<li>Waterproof Protection<\/li>\n<li>Quick Connect Digital Probe<\/li>\n<li>Auto-sensor Recognition<\/li>\n<li>Data Logging<\/li>\n<li><span style=\"font-size: 20px;\">PC Connectivity<\/span><\/li>\n<li>GLP Data<\/li>\n<li>Dedicated Help Key<\/li>\n<li>Long Battery Life<\/li>\n<li>Versatility when you need it<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section two\">\n<div class=\"section-text col-xs-12 col-sm-6 add-p-r\"><\/div>\n<div class=\"section-text col-xs-12 col-sm-6 add-p-l\">\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section four\">\n<div class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\">\n<h3>Conductivity<\/h3>\n<p>The HI98199 also can measure conductivity via separate Electrode.<\/p>\n<p>conductivity electrode model is : HI763093<\/p>\n<p>HI76303 can measure conductivity, TDS (total dissolved solids), Resistivity, Salinity, seawater \u03c3, and temperature .<\/p>\n<p>Some details of conductivity probe been listed as below:<\/p>\n<ul>\n<li>Single-point calibration from six standards<\/li>\n<li>Temperature compensation Automatic Temperature Compensation<\/li>\n<li>Configurable temperature coefficient range from 0.00 to 6.00%\/\u00b0C<\/li>\n<li>Choice of reference temperatures at 20 or 25\u00b0C<\/li>\n<li>Absolute conductivity can be displayed along with the temperature compensated value<\/li>\n<\/ul>\n<h3>Auto-ranging<\/h3>\n<p>Ec electrode can measure salinity in PSU scale.<\/p>\n<\/div>\n<div class=\"section-image col-xs-12 col-sm-5 rem-p-r\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/98199_with_EC_2020_with_probe.jpg\" alt=\"\" \/><\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section five\">\n<div class=\"section-image col-xs-12 col-sm-5 rem-p-l\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/98199_with_DO_probe_2020.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-text hidden-xs col-sm-7 add-p-l rem-p-r\">\n<h3>Dissolved Oxygen<\/h3>\n<p>The HI98199 can measure Dissolved Oxygen and\u00a0 atmospheric pressure, and temperature with the optional HI764103 digital DO probe.<\/p>\n<ul>\n<li>Display units in % saturation or ppm (mg\/L)<\/li>\n<li>Salinity compensation for saline waters Manual entry of salinity values<\/li>\n<li>Readings compensated for salinity effects<\/li>\n<li>Built-in barometer Automatic compensation for changes in atmospheric pressure<\/li>\n<li>User selectable units<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section six\">\n<div class=\"section-text col-xs-12 col-md-4 rem-p-l add-p-r\">\n<h3>HI-98199 Quick Connect view<\/h3>\n<\/div>\n<div class=\"section-image hidden-xs col-sm-6 col-md-4 l-image rem-p-l\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/98199_meter_quick_connect_view.jpg\" alt=\"\" \/><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/section>\n<div id=\"specifications\" class=\"specification col-xs-12\">\n<article>\n<h2><\/h2>\n<section>\n<div class=\"table\">\n<div class=\"section-row section spec\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<h3>Specifications of HI98199<\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>pH \/ mV (using the included HI-829113 pH Probe)<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003 Range<\/td>\n<td><\/td>\n<td>0.00 to 14.00 pH \/ \u00b1600.0 mV<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>0.01 pH \/ 0.1 mV<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.02 pH \/ \u00b10.5 mV<\/td>\n<\/tr>\n<tr>\n<td>\u2003Calibration<\/td>\n<td><\/td>\n<td>Automatic one, two, or three points of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer<\/td>\n<\/tr>\n<tr>\n<td><b>EC (using HI-763093 EC Probe \u2013 buy separately)<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Range<\/td>\n<td><\/td>\n<td>0 to 200 mS\/cm<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>manual: 1 \u03bcS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; 1 mS\/cm; automatic: 1 \u03bcS\/cm from 0 to 9999 \u03bcS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 200.0 mS\/cm automatic mS\/cm: 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 200.0 mS\/cm<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy<\/td>\n<td><\/td>\n<td>\u00b11.5% of reading or \u00b12 \u03bcS\/cm whichever is greater<\/td>\n<\/tr>\n<tr>\n<td>\u2003Calibration<\/td>\n<td><\/td>\n<td>Automatic single point, with six standard solutions (84 \u03bcS\/cm, 1413 \u03bcS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point<\/td>\n<\/tr>\n<tr>\n<td><b>TDS (using HI-763093 EC Probe &#8211; buy separately)<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003 Range<\/td>\n<td><\/td>\n<td>0.0 to 200.0 ppt (g\/L) (the maximum value depends on the TDS factor)<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>manual: 1 ppm (mg\/L); 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L); automatic: 1 ppm (mg\/L) from 0 to 9999 ppm (mg\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 200.0 ppt (g\/L) automatic ppt (g\/L): 0.001 ppt (g\/L) from 0.000 to 9.999 ppt (g\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 200.0 ppt (g\/L)<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy<\/td>\n<td><\/td>\n<td>\u00b11% of reading or \u00b11 ppm (mg\/L) whichever is greater<\/td>\n<\/tr>\n<tr>\n<td>\u2003Calibration<\/td>\n<td><\/td>\n<td>based on conductivity calibration<\/td>\n<\/tr>\n<tr>\n<td><b>Resistivity (using HI-763093 EC Probe &#8211; buy separately)<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003 Range<\/td>\n<td><\/td>\n<td>0 to 999999 \u03a9\u2022cm; 0 to 1000.0 k\u03a9\u2022cm; 0 to 1.0000 M\u03a9\u2022cm<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>1 \u03a9\u2022cm; 0.1 k\u03a9\u2022cm; 0.0001 M\u03a9\u2022cm<\/td>\n<\/tr>\n<tr>\n<td>\u2003Calibration<\/td>\n<td><\/td>\n<td>based on conductivity calibration<\/td>\n<\/tr>\n<tr>\n<td><b>Salinity (using HI-763093 EC Probe \u2013 buy separately)<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003 Range<\/td>\n<td><\/td>\n<td>0.00 to 70.00 PSU<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>0.01 PSU<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy<\/td>\n<td><\/td>\n<td>\u00b12% of reading or \u00b10.01 PSU whichever is greater<\/td>\n<\/tr>\n<tr>\n<td>\u2003Calibration<\/td>\n<td><\/td>\n<td>based on conductivity calibration<\/td>\n<\/tr>\n<tr>\n<td><b>Seawater \u03c3 (using HI-763093 EC Probe \u2013 buy separately)<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Range<\/td>\n<td><\/td>\n<td>0.0 to 50.0 \u03c3t, \u03c3\u2080, \u03c3\u2081\u2085<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>0.1 \u03c3t, \u03c3\u2080, \u03c3\u2081\u2085<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy<\/td>\n<td><\/td>\n<td>\u00b11 \u03c3t, \u03c3\u2080, \u03c3\u2081\u2085<\/td>\n<\/tr>\n<tr>\n<td>\u2003Calibration<\/td>\n<td><\/td>\n<td>based on conductivity calibration<\/td>\n<\/tr>\n<tr>\n<td><b>Dissolved Oxygen (using HI-764103 DO Probe &#8211; buy separately)<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Range<\/td>\n<td><\/td>\n<td>0.0 to 500.0%; 0.00 to 50.00 ppm (mg\/L)<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>0.1%; 0.01 ppm (mg\/L)<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy<\/td>\n<td><\/td>\n<td>0.0 to 300.0%: \u00b11.5% of reading or \u00b11.0% whichever is greater; 300.0 to 500.0%: \u00b13% of reading; 0.00 to 30.00 ppm (mg\/L): \u00b11.5% of reading or \u00b10.10 ppm (mg\/L), whichever is greater; 30.00 ppm (mg\/L) to 50.00 ppm (mg\/L): \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>\u2003Calibration<\/td>\n<td><\/td>\n<td>automatic one or two points at 0, 100% or one custom point<\/td>\n<\/tr>\n<tr>\n<td><b>Atmospheric Pressure (using HI-764103 DO Probe \u2013 buy separately)<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Range<\/td>\n<td><\/td>\n<td>450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy<\/td>\n<td><\/td>\n<td>\u00b13 mm Hg within \u00b115\u00b0C from the temperature during calibration<\/td>\n<\/tr>\n<tr>\n<td>\u2003Calibration<\/td>\n<td><\/td>\n<td>automatic at one custom point<\/td>\n<\/tr>\n<tr>\n<td><b>Temperature<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Range<\/td>\n<td><\/td>\n<td>-5.00 to 55.00\u00b0C; 23.00 to 131.00\u00b0F; 268.15 to 328.15K<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>0.01\u00b0C; 0.01\u00b0F; 0.01K<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.15\u00b0C; \u00b10.27\u00b0F; \u00b10.15K<\/td>\n<\/tr>\n<tr>\n<td>\u2003Calibration<\/td>\n<td><\/td>\n<td>automatic at one custom point<\/td>\n<\/tr>\n<tr>\n<td><b>Additional specifications<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Temp compensation<\/td>\n<td><\/td>\n<td>automatic from -5 to 55\u00b0C (23 to 131\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>\u2003Logging Memory<\/td>\n<td><\/td>\n<td>45000 records (continuous logging or log-on-demand)<\/td>\n<\/tr>\n<tr>\n<td>\u2003Logging Interval<\/td>\n<td><\/td>\n<td>one second to three hours<\/td>\n<\/tr>\n<tr>\n<td>\u2003PC Connectivity<\/td>\n<td><\/td>\n<td>via USB (with Hanna PC software)<\/td>\n<\/tr>\n<tr>\n<td>\u2003Environment<\/td>\n<td><\/td>\n<td>0 to 50\u00b0C (32 to 122\u00b0F); RH 100% IP67<\/td>\n<\/tr>\n<tr>\n<td>\u2003Battery Type \/ Life<\/td>\n<td><\/td>\n<td>1.5V AA batteries (4) \/ approximately 400 hours of continuous use without backlight (50 hours with backlight)<\/td>\n<\/tr>\n<tr>\n<td>\u2003Dimensions \/ Weight<\/td>\n<td><\/td>\n<td>185.0 x 93.0 x 35.2 mm (7.3 x 3.6 x 1.4\u201d) \/ 400 g (14.2 oz.)<\/td>\n<\/tr>\n<tr>\n<td><b>Ordering Information<\/b><\/td>\n<td><\/td>\n<td>HI-98199 is supplied with the HI-829113 pH digital probe with 4m (13\u2019) cable, pH calibration solution sachets, PC software, micro USB cable, batteries, quality certificate, and instruction manual in a rugged carrying case.<\/td>\n<\/tr>\n<tr>\n<td><b>Probes<\/b><\/td>\n<td><\/td>\n<td>HI-829113 pH digital probe with 4m (13\u2019) cable (supplied); HI-763093 EC digital probe with 4m (13\u2019) cable (buy separately); HI-764103 DO digital probe with 4m (13\u2019) cable (buy separately)<\/td>\n<\/tr>\n<tr>\n<td><b>Accessories<\/b><\/td>\n<td><\/td>\n<td>HI-710034 orange protective silicone rubber boot<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/article>\n<\/div>\n<div>\n<div class=\"section\">\n<div id=\"reviews\" class=\"product-reviews desktop\">\n<div class=\"reviews-links\">To know <strong><a href=\"http:\/\/www.hannainst.com\">HI98199 HANNA<\/a> price<\/strong> or <strong>buy HI98199 Multiparameter<\/strong> , please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>HI98199 Multiparameter<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":4257,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4256"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4256"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4257"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4256"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}