{"id":4260,"date":"2020-11-28T15:19:35","date_gmt":"2020-11-28T16:19:35","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4260"},"modified":"2025-03-05T09:19:44","modified_gmt":"2025-03-05T10:19:44","slug":"hi2550-multiparameter","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi2550-multiparameter\/","title":{"rendered":"HI2550 Multiparameter"},"content":{"rendered":"<h2>HI2550 Multiparameter<\/h2>\n<h3>HI2550 pH\/mV\/EC\/TDS\/NaCl\/\u00b0C Meter &#8211; 2 Channel<\/h3>\n<div id=\"attachment_4262\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4262\" loading=\"lazy\" class=\"size-medium wp-image-4262\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1-300x300.jpg\" alt=\"HI2550 Multiparameter\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1-300x300.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1-100x100.jpg 100w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-4262\" class=\"wp-caption-text\">HI2550 Multiparameter<\/p><\/div>\n<h3>Product information &#8220;HI2550 pH\/mV\/EC\/TDS\/NaCl\/\u00b0C Meter &#8211; 2 Channel&#8221;<\/h3>\n<p>HI 2550 is a bench top multi parameter device that measure pH, ORP, ISE, conductivity (EC), TDS, NaCl percentage and temperature.<\/p>\n<p>HI2550 has 2 seperate channel .<\/p>\n<p>HI2550 measure 7\u00a0 parameters.<\/p>\n<p>&nbsp;<\/p>\n<p>pH prob in HI2550 can measure temperature too.<\/p>\n<p>pH calibrations are up to five calibration points, chosen from the seven available memorized buffers.<\/p>\n<p>HI2550 measure using ORP electrodes (pH channel input).<\/p>\n<p>another Elcterode MOdel : HI76310 using for measuring EC\/ TDS\/ SALINITY.<\/p>\n<p>HI2550 has GLP capability<\/p>\n<p>pH electrode in HI2550 can be calibrate in 5 points.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Order Information:<\/strong>\u00a0\u00a0 HI 2550-02 (230V) are supplied with HI 1131B pH electrode, HI 76310 conductivity\/TDS probe, HI 7662 temperature probe, HI 76404N electrode holder, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 7071S electrolyte solution (30 mL), 12 VDC adapter and instruction manual.<\/p>\n<div>To know <strong><a href=\"http:\/\/www.hannainst.com\">HI2550 HANNA<\/a> price<\/strong> or buy <strong>HI2550 Multiparameter ,\u00a0<\/strong>please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/div>\n<p><strong>HI2550 Multiparameter\u00a0 Specification :<\/strong><\/p>\n<table id=\"zebra\" class=\"spec_table\">\n<tbody>\n<tr>\n<td><strong>Range<\/strong><\/td>\n<td><strong><small>pH<\/small><\/strong><\/td>\n<td><small>-2.0 to 16.0 pH; -2.00 to 16.00 pH; -2.000 to 16.000 pH<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>ISE &amp; ORP<\/small><\/strong><\/td>\n<td><small>\u00b1999.9 mV (ISE &amp; ORP); \u00b12000 mV (ISE &amp; ORP)<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>EC<\/small><\/strong><\/td>\n<td><small>0.00 to 29.99 \u00b5S\/cm; 30.0 to 299.9 \u00b5S\/cm; 300 to 2999 \u00b5S\/cm;\u00a0 3.00 to 29.99 mS\/cm; 30.0 to 200.0 mS\/cm; up to 500.0 mS\/cm actual conductivity<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>TDS<\/small><\/strong><\/td>\n<td><small>0.00 to 14.99 ppm; 15.0 to 149.9 ppm; 150 to 1499 ppm; 1.50 to 14.99 g\/L; 15.0 to 100.0 g\/L; up to 400.0 g\/L actual TDS (with 0.80 factor)<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>NaCl<\/small><\/strong><\/td>\n<td><small>0.0 to 400.0% NaCl<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>Temperature<\/small><\/strong><\/td>\n<td><small>\u201320.0 to 120.0 \u00baC (pH, EC range)<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong><small>pH<\/small><\/strong><\/td>\n<td><small>0.1 pH; 0.01 pH; 0.001 pH<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>ISE &amp; ORP<\/small><\/strong><\/td>\n<td><small>0.1 mV (\u00b1999.9 mV); 1 mV (\u00b1 2000 mV)<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>TDS<\/small><\/strong><\/td>\n<td><small>0.01 ppm; 0.1 ppm; 1 ppm; 0.01 g\/L; 0.1 g\/L<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>NaCl<\/small><\/strong><\/td>\n<td><small>0.1% NaCl<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>Temperature<\/small><\/strong><\/td>\n<td><small>0.1 \u00baC<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Accuracy @ 20\u00b0C<\/strong><\/td>\n<td><strong><small>pH<\/small><\/strong><\/td>\n<td><small>\u00b10.01 pH; \u00b10.002 pH<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>ISE &amp; ORP<\/small><\/strong><\/td>\n<td><small>\u00b10.2 mV (\u00b1999.9 mV); \u00b11 mV (\u00b12000 mV)<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>EC<\/small><\/strong><\/td>\n<td><small>\u00b11 % reading (\u00b10.05 \u00b5S\/cm or 1 digit, whichever greater)<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>TDS<\/small><\/strong><\/td>\n<td><small>\u00b11% of reading (\u00b10.03 ppm or 1 digit, whichever greater)<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>NaCl<\/small><\/strong><\/td>\n<td><small>\u00b11% of reading<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>Temperature<\/small><\/strong><\/td>\n<td><small>\u00b10.4 \u00baC (excluding probe error)<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Calibration<\/strong><\/td>\n<td><strong><small>pH<\/small><\/strong><\/td>\n<td><small>up to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and two custom buffers<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>EC<\/small><\/strong><\/td>\n<td><small>two point calibration; one point slope calibration; six buffers available: 84.0, 1413 \u00b5S\/cm; 5.00, 12.88, 80.0, 111.8 mS\/cm; one point offset: 0.00 \u00b5S\/cm<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>NaCl<\/small><\/strong><\/td>\n<td><small>one point with HI 7037L standard (optional)<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Probes<\/strong><\/td>\n<td><strong><small>pH<\/small><\/strong><\/td>\n<td><small>HI 1131B glass body pH electrode with BNC connector and 1 m (3.3&#8242;) cable (included)<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>EC<\/small><\/strong><\/td>\n<td><small>HI 76310 platinum four ring conductivity\/TDS probe with built-in temperature sensor and 1 m (3.3&#8242;) cable (included)<\/small><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong><small>Temperature<\/small><\/strong><\/td>\n<td><small>HI 7662 temperature probe with 1 m (3.3&#8242;) cable (included)<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Relative mV Offset<\/strong><\/td>\n<td><\/td>\n<td><small>\u00b12000 mV<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Temperature Compensation<\/strong><\/td>\n<td><\/td>\n<td><small>manual or automatic from: -20.0 to 120.0 \u00baC (pH range) -20.0 to 120.0 \u00baC (EC range) (can be disabled on conductivity range to measure actual conductivity)<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Cond. Temp. Coefficient<\/strong><\/td>\n<td><\/td>\n<td><small>0.00 to 6.00 %\/\u00baC (for EC and TDS only) default value is 1.90 %\/\u00baC<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>TDS Factor<\/strong><\/td>\n<td><\/td>\n<td><small>0.40 to 0.80 (default value is 0.50)<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Input Impedance<\/strong><\/td>\n<td><\/td>\n<td><small>10<sup>12<\/sup>\u00a0ohms<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>PC Connectivity<\/strong><\/td>\n<td><\/td>\n<td><small>opto-isolated USB<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Log on Demand<\/strong><\/td>\n<td><\/td>\n<td><small>200 records<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Log Interval Feature<\/strong><\/td>\n<td><\/td>\n<td><small>500 records; 5, 10, 30 sec and 1, 2, 5, 10, 15, 30, 60, 120, 180 min stability logging (\u201cStAb\u201d)<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Power Supply<\/strong><\/td>\n<td><\/td>\n<td><small>12 VDC<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Environment<\/strong><\/td>\n<td><\/td>\n<td><small>0 to 50\u00b0C (32 to 122\u00b0F); RH max 95% non-condensing<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Dimensions<\/strong><\/td>\n<td><\/td>\n<td><small>235 x 218 x 108 mm (9.2 x 8.5 x 4.2\u201d)<\/small><\/td>\n<\/tr>\n<tr>\n<td><strong>Weight<\/strong><\/td>\n<td><\/td>\n<td><small>1.3 Kg (2.9 lb); kit with holder 2.1 Kg (4.6 lb.)<\/small><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<h3>HI2550 Multiparameter<\/h3>\n<h3>HI2550 pH\/mV\/EC\/TDS\/NaCl\/\u00b0C Meter &#8211; 2 Channel<\/h3>\n[caption id=\"attachment_4262\" align=\"aligncenter\" width=\"300\"]<img loading=\"lazy\" class=\"size-medium wp-image-4262\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1-300x300.jpg\" alt=\"HI2550 Multiparameter\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1-300x300.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1-100x100.jpg 100w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI2550-1-1.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> HI2550 Multiparameter[\/caption]\n<h3>Product information &#8220;HI2550 pH\/mV\/EC\/TDS\/NaCl\/\u00b0C Meter &#8211; 2 Channel&#8221;<\/h3>\n<p>HI 2550 is a 2 channel instrument that measures up to 7 parameters. With this single laboratory bench meter you can measure pH, ORP, ISE, conductivity (EC), TDS, NaCl percentage and temperature.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":4261,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4260"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4260"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4261"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4260"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}