{"id":4356,"date":"2020-11-30T17:25:19","date_gmt":"2020-11-30T18:25:19","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4356"},"modified":"2021-04-27T15:25:24","modified_gmt":"2021-04-27T15:25:24","slug":"hi83306-multiparameter-photometer","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi83306-multiparameter-photometer\/","title":{"rendered":"HI83306 Multiparameter Photometer"},"content":{"rendered":"<h2>HI83306 Multiparameter Photometer<\/h2>\n<div id=\"attachment_4357\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4357\" loading=\"lazy\" class=\"size-medium wp-image-4357\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI83306-300x300.jpg\" alt=\"HI83306 Multiparameter Photometer\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI83306-300x300.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI83306-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI83306-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI83306-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI83306-100x100.jpg 100w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/HI83306.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-4357\" class=\"wp-caption-text\">HI83306 Multiparameter Photometer<\/p><\/div>\n<p>HI83306 is Multiparameter Photometer with modern and optical design and suit device for\u00a0 environmental laboratory .<\/p>\n<p>HI83306 works with photometric method.<\/p>\n<p>HI83306 measurs pH via an optional Ph electrode.<\/p>\n<p>&nbsp;<\/p>\n<div id=\"attachment_4358\" style=\"width: 310px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-4358\" loading=\"lazy\" class=\"size-medium wp-image-4358\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/83306-1-300x162.png\" alt=\"HI83306\" width=\"300\" height=\"162\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/83306-1-300x162.png 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/83306-1.png 306w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-4358\" class=\"wp-caption-text\">HI83306<\/p><\/div>\n<div id=\"attachment_4359\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-4359\" loading=\"lazy\" class=\"size-full wp-image-4359\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/83306-2.jpg\" alt=\"HI83306\" width=\"225\" height=\"225\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/83306-2.jpg 225w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/83306-2-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/83306-2-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/83306-2-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/11\/83306-2-100x100.jpg 100w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><p id=\"caption-attachment-4359\" class=\"wp-caption-text\">HI83306<\/p><\/div>\n<section>\n<article>\n<div class=\"section-row\">\n<div id=\"extended-description-tabs\" class=\"extended-description\">\n<div class=\"row\">\n<div id=\"description\" class=\"section-row section 1\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<p>HI83306 measure 16 key water quality parameters with 23 different programmed methods.<\/p>\n<p>HI83306 is useful device to measure Environmental parameters include nitrate, phosphorous and dissolved oxygen.<\/p>\n<p>&nbsp;<\/p>\n<h3>Key features of HI83300 been listed as below:<\/h3>\n<ul>\n<li>Backlit 128 x 64 Pixel Graphic Liquid Crystal Display<\/li>\n<li>Built-in Reaction Timer for Photometric Measurements<\/li>\n<li>Absorbance mode &#8211; concentration versus absorbance<\/li>\n<li>Units of Measurement plus chemical form displayed<\/li>\n<li>Result conversion at the touch of a button<\/li>\n<li>Cuvette cover<\/li>\n<li>pH and temperature measurement with a single probe<\/li>\n<li>Good Laboratory Practice (GLP) &#8211; track calibration information including date, time, buffers used, offset and slope for traceability<\/li>\n<li>pH CAL Check alerts user to potential problems during the calibration process<\/li>\n<li>Data Logging &#8211; Up to 1000 photometric and pH readings can be stored.<\/li>\n<li>Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.<\/li>\n<li>Battery Status Indicator<\/li>\n<li>Error Messages<\/li>\n<\/ul>\n<h3>HI83306 characteristics been listed as below:<\/h3>\n<ul>\n<li>High Efficiency LED Light Source<\/li>\n<\/ul>\n<ul>\n<li>High Quality Narrow Band Interference Filters<\/li>\n<\/ul>\n<ul>\n<li>Reference Detector for a Stable Light Source<\/li>\n<\/ul>\n<ul>\n<li>Large Cuvette Size<\/li>\n<\/ul>\n<ul>\n<li>Focusing Lens for Greater Light Yield<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/section>\n<div id=\"specifications\" class=\"specification col-xs-12\">\n<article>\n<h2><span style=\"font-size: 20px;\">HI83306 Multiparameter Photometer Specifications<\/span><\/h2>\n<section>\n<div class=\"table\">\n<div class=\"section-row section spec\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<table>\n<tbody>\n<tr>\n<td>Input Channels<\/td>\n<td><\/td>\n<td>1 pH electrode input and 5 photometer wavelengths<\/td>\n<\/tr>\n<tr>\n<td>pH Electrode<\/td>\n<td><\/td>\n<td>Digital pH electrode (not included)<\/td>\n<\/tr>\n<tr>\n<td>Logging type<\/td>\n<td><\/td>\n<td>Log on demand with user name and sample ID optional input<\/td>\n<\/tr>\n<tr>\n<td>Logging Memory<\/td>\n<td><\/td>\n<td>1000 readings<\/td>\n<\/tr>\n<tr>\n<td>Connectivity<\/td>\n<td><\/td>\n<td>USB-A host for flash drive; micro-USB-B for power and computer connectivity<\/td>\n<\/tr>\n<tr>\n<td>GLP<\/td>\n<td><\/td>\n<td>Calibration data for connected pH electrode<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td><\/td>\n<td>128 x 64 pixel LCD with backlight<\/td>\n<\/tr>\n<tr>\n<td>Battery Type\/Life<\/td>\n<td><\/td>\n<td>3.7 VDC Li-polymer rechargeable battery\/ &gt;500 photometric measurements or 50 hours of continuous pH measurement<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td><\/td>\n<td>5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)<\/td>\n<\/tr>\n<tr>\n<td>Environment<\/td>\n<td><\/td>\n<td>0 to 50.0\u00b0C (32 to 122.0\u00b0F; 0 to 95% RH, non-condensing<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td><\/td>\n<td>206 x 177 x 97mm (8.1 x 7.0 x 3.8&#8243;)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td><\/td>\n<td>1.0 kg (2.2lbs)<\/td>\n<\/tr>\n<tr>\n<td>Photometer\/Colorimeter Light Source<\/td>\n<td><\/td>\n<td>5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters<\/td>\n<\/tr>\n<tr>\n<td>Photometre\/Colorimeter Light Detector<\/td>\n<td><\/td>\n<td>Silicon Photodetector<\/td>\n<\/tr>\n<tr>\n<td>Bandpass filter Bandwidth<\/td>\n<td><\/td>\n<td>8nm<\/td>\n<\/tr>\n<tr>\n<td>Bandpass filter wavelength accruacy<\/td>\n<td><\/td>\n<td>+-1nm<\/td>\n<\/tr>\n<tr>\n<td>Cuvette Type<\/td>\n<td><\/td>\n<td>Round, 24.6mm<\/td>\n<\/tr>\n<tr>\n<td>Number of Methods<\/td>\n<td><\/td>\n<td>128 Max<\/td>\n<\/tr>\n<tr>\n<td>Ordering Information<\/td>\n<td><\/td>\n<td>HI-83306 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>AMMONIA<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Ammonia Range<\/td>\n<td><\/td>\n<td>Low Range: 0.00 to 3.00 mg\/L (as NH3-N) Medium Range: 0.00 to 10.00 mg\/L (as NH3-N) High Range: 0.0 to 100.0 mg\/L (as NH3-N)<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.04 mg\/L \u00b14% of reading Medium Range: \u00b10.05 mg\/L \u00b15% of reading High range: \u00b10.5 mg\/L \u00b15% of reading at 25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Method<\/td>\n<td><\/td>\n<td>Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CHLORINE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Free Chlorine Range<\/td>\n<td><\/td>\n<td>0.00 to 5.00 mg\/L (as Cl2)<\/td>\n<\/tr>\n<tr>\n<td>Free Chlorine Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Free Chlorine Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorine Range<\/td>\n<td><\/td>\n<td>0.00 to 5.00 mg\/L (as Cl2)<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorine Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorine Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Method<\/td>\n<td><\/td>\n<td>Adaptation of the EPA 330.5 DPD method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CHROMIUM, HEXAVALENT<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Chromium, Hexavalent Range<\/td>\n<td><\/td>\n<td>Low Range: 0 to 300 \u03bcg\/L (as Cr6+) High Range: 0 to 1000 \u03bcg\/L (as Cr6+)<\/td>\n<\/tr>\n<tr>\n<td>Chromium, Hexavalent Resolution<\/td>\n<td><\/td>\n<td>1 \u03bcg\/L<\/td>\n<\/tr>\n<tr>\n<td>Chromium, Hexavalent Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b11 \u03bcg\/L \u00b14% of reading High Range: \u00b15 \u03bcg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Chromium, Hexavalent Method<\/td>\n<td><\/td>\n<td>Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>COLOUR, WATER<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Colour, Water Range<\/td>\n<td><\/td>\n<td>0 to 500 PCU (Platinum Cobalt Units)<\/td>\n<\/tr>\n<tr>\n<td>Colour, Water Resolution<\/td>\n<td><\/td>\n<td>1 PCU<\/td>\n<\/tr>\n<tr>\n<td>Colour, Water Accuracy<\/td>\n<td><\/td>\n<td>\u00b110 PCU \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Colour, Water Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>COPPER<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Copper Range<\/td>\n<td><\/td>\n<td>Low Range: 0.000 to 1.500 mg\/L (as Cu2+) High range: 0.00 to 5.00 mg\/L (as Cu2+)<\/td>\n<\/tr>\n<tr>\n<td>Copper Resolution<\/td>\n<td><\/td>\n<td>0.001 mg\/L; 0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Copper Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.01 mg\/L \u00b15% of reading High Range \u00b10.02 mg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Copper Method<\/td>\n<td><\/td>\n<td>Adaptation of the EPA bicinchoninate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CYANURIC ACID<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid Range<\/td>\n<td><\/td>\n<td>0 to 80 mg\/L (as CYA)<\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid Accuracy<\/td>\n<td><\/td>\n<td>\u00b11 mg\/L \u00b115% of reading<\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid Method<\/td>\n<td><\/td>\n<td>Adaptation of the turbidimetric method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>MOLYBDENUM<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Molybdenum Range<\/td>\n<td><\/td>\n<td>0.0 to 40.0 mg\/L (as Mo6+)<\/td>\n<\/tr>\n<tr>\n<td>Molybdenum Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Molybdenum Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.3 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Molybdenum Method<\/td>\n<td><\/td>\n<td>Adaptation of the mercaptoacetic acid method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>NICKEL<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nickel Range<\/td>\n<td><\/td>\n<td>Low Range: 0.000 to 1.000 mg\/L (as Ni) High Range: 0.00 to 7.00 g\/L (as Ni)<\/td>\n<\/tr>\n<tr>\n<td>Nickel Resolution<\/td>\n<td><\/td>\n<td>0.001 mg\/L; 0.01 g\/L<\/td>\n<\/tr>\n<tr>\n<td>Nickel Accuracy<\/td>\n<td><\/td>\n<td>Low range: \u00b10.010 mg\/L \u00b17% of reading High Range: \u00b10.07 g\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Nickel Method<\/td>\n<td><\/td>\n<td>Low Range: Adaptation of the PAN method High Range: Adaptation of the photometric method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>NITRATE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nitrate Range<\/td>\n<td><\/td>\n<td>0.0 to 30.0 mg\/L (as NO3&#8211; N)<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.5 mg\/L \u00b110% of reading<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Method<\/td>\n<td><\/td>\n<td>Adaptation of the cadmium reduction method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>NITRITE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nitrite Range<\/td>\n<td><\/td>\n<td>Freshwater High Range: 0 to 150 mg\/L (as NO2-)<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Resolution<\/td>\n<td><\/td>\n<td>Freshwater: 1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Accuracy<\/td>\n<td><\/td>\n<td>Freshwater High Range: \u00b14 mg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Method<\/td>\n<td><\/td>\n<td>HR &#8211; Adaptation of the Ferrous Sulphate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>OXYGEN, DISSOLVED<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Range<\/td>\n<td><\/td>\n<td>0.0 to 10.0 mg\/L (as O2)<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.4 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>pH<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>pH Range<\/td>\n<td><\/td>\n<td>Photometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Resolution<\/td>\n<td><\/td>\n<td>Photometer: 0.1 pH pH electrode: 0.1 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Accuracy<\/td>\n<td><\/td>\n<td>Photometer: \u00b10.1 pH pH electrode: \u00b10.01 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Calibration<\/td>\n<td><\/td>\n<td>Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)<\/td>\n<\/tr>\n<tr>\n<td>pH Temperature Compensation<\/td>\n<td><\/td>\n<td>Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used<\/td>\n<\/tr>\n<tr>\n<td>pH CAL Check (electrode diagnostics)<\/td>\n<td><\/td>\n<td>clean electrode and check buffer\/check probe displayed during calibration<\/td>\n<\/tr>\n<tr>\n<td>pH Method<\/td>\n<td><\/td>\n<td>Photometer: phenol red<\/td>\n<\/tr>\n<tr>\n<td>pH-mV Range<\/td>\n<td><\/td>\n<td>\u00b11000 mV<\/td>\n<\/tr>\n<tr>\n<td>pH-mV Resolution<\/td>\n<td><\/td>\n<td>0.1 mV<\/td>\n<\/tr>\n<tr>\n<td>pH-mV Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.2 mV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>PHOSPHATE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Phosphate Range<\/td>\n<td><\/td>\n<td>Freshwater Low Range: 0.00 to 2.50 mg\/L (as PO43-) High range: 0.0 to 30.0 mg\/L (as PO43-)<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Resolution<\/td>\n<td><\/td>\n<td>Freshwater: 0.01 mg\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Accuracy<\/td>\n<td><\/td>\n<td>Freshwater Low Range: \u00b10.04 mg\/L \u00b14% of reading High Range: \u00b11 mg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Method<\/td>\n<td><\/td>\n<td>Freshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>SILICA<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Silica Range<\/td>\n<td><\/td>\n<td>Low Range: 0.00 to 2.00 mg\/L (as SiO2)<\/td>\n<\/tr>\n<tr>\n<td>Silica Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Silica Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Silica Method<\/td>\n<td><\/td>\n<td>Low Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>SILVER<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Silver Range<\/td>\n<td><\/td>\n<td>0.000 to 1.000 mg\/L (as Ag)<\/td>\n<\/tr>\n<tr>\n<td>Silver Resolution<\/td>\n<td><\/td>\n<td>0.001 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Silver Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.020 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Silver Method<\/td>\n<td><\/td>\n<td>Adaptation of the PAN method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>ZINC<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Zinc Range<\/td>\n<td><\/td>\n<td>0.00 to 3.00 mg\/L (as Zn)<\/td>\n<\/tr>\n<tr>\n<td>Zinc Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Zinc Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Zinc Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>REAGENTS<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Ammonia HR, MR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93733-01 (100 tests); HI-93733-03 (300 tests); MR &#8211; HI-93715-01 (100 tests); HI-93715-03 (300 tests); LR &#8211; HI-93700-01 (100 tests); HI-93700-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chlorine &#8211; Free<\/td>\n<td><\/td>\n<td>Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Total<\/td>\n<td><\/td>\n<td>HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)<br \/>\nChlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chromium VI \u2013 HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93723-01 (100 tests); HI-93723-03 (300 tests)<br \/>\nLR &#8211; HI-93749-01 (100 tests); HI-93749-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Copper \u2013 HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93702-01 (100 tests); HI-93702-03 (300 tests)<br \/>\nLR &#8211; HI-95747-01 (100 tests); HI-95747-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid<\/td>\n<td><\/td>\n<td>HI-93722-01 (100 tests); HI-93722-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Molybdenum<\/td>\n<td><\/td>\n<td>HI-93730-01 (100 tests); HI-93730-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Nickel &#8211; HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93726-01 (100 tests); HI-93726-03 (300 tests)<br \/>\nLR &#8211; HI-93740-01 (50 tests); HI-93740-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Nitrate<\/td>\n<td><\/td>\n<td>HI-93728-01 (100 tests); HI-93728-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Nitrite \u2013 HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93708-01 (100 tests); HI-93708-03 (300 tests)<br \/>\nLR &#8211; HI-93707-01 (100 tests); HI-93707-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved (DO)<\/td>\n<td><\/td>\n<td>HI-93732-01 (100 tests); HI-93732-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>pH<\/td>\n<td><\/td>\n<td>HI-93710-01 (100 tests); HI-93710-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Phosphate &#8211; HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93717-01 (100 tests); HI-93717-03 (300 tests)<br \/>\nLR &#8211; HI-93713-01 (100 tests); HI-93713-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Silica \u2013 LR<\/td>\n<td><\/td>\n<td>LR &#8211; HI-93705-01 (100 tests); HI-93705-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Silver<\/td>\n<td><\/td>\n<td>HI-93737-01 (50 tests); HI-93737-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Zinc<\/td>\n<td><\/td>\n<td>HI-93731-01 (100 tests); HI-93731-03 (300 tests)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/article>\n<\/div>\n<p>To know <strong>HI83306 <a href=\"http:\/\/www.hannainst.com\">HANNA<\/a> price<\/strong> or <strong>buy HI83306 Multiparameter Photometer<\/strong> ,please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong> HI83306 Multiparameter Photometer<\/strong><\/p>\n<p>One meter can be used for both photometric and pH measurements. HI-83306 is a compact, multi-parameter photometer for use in the environmental lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.<\/p>\n","protected":false},"featured_media":4357,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4356"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4356"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4357"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4356"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}