{"id":4361,"date":"2020-12-01T10:16:46","date_gmt":"2020-12-01T11:16:46","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4361"},"modified":"2021-04-27T15:15:41","modified_gmt":"2021-04-27T15:15:41","slug":"hi83303-multiparameter-photometer","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi83303-multiparameter-photometer\/","title":{"rendered":"HI83303 Multiparameter Photometer"},"content":{"rendered":"<h2>HI83303 Multiparameter Photometer<\/h2>\n<div id=\"attachment_4362\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4362\" class=\"size-medium wp-image-4362\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303-300x300.jpg\" alt=\"HI83303 Multiparameter Photometer\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303-300x300.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303-100x100.jpg 100w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303.jpg 400w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-4362\" class=\"wp-caption-text\">HI83303 Multiparameter Photometer<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>The HI83303 is a multiparameter Photometer with very small and modern size to measure water parameters.<\/p>\n<p>HI83303 is proper device for aquaculture industry .<\/p>\n<p>HI83300 measures 12 key water quality parameters.<\/p>\n<p>HI83303 measure pH with a digital pH PROBE.<\/p>\n<p>pH prob in HI83300 measure temperature too.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 20px; font-weight: 600;\">HI-83303 Aquaculture Photometer with pH meter<\/span><\/p>\n<section>\n<article>\n<div class=\"section-row\">\n<div id=\"extended-description-tabs\" class=\"extended-description\">\n<div class=\"row\">\n<div id=\"description\" class=\"section-row section 1\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<p>HI83303 works with optical system.<\/p>\n<p>HI83303 measure Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4363 aligncenter\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-1.jpg\" alt=\"\" width=\"225\" height=\"225\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-1.jpg 225w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-1-100x100.jpg 100w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-1-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-1-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-1-180x180.jpg 180w\" sizes=\"auto, (max-width: 225px) 100vw, 225px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-4364 aligncenter\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-2-300x162.png\" alt=\"\" width=\"300\" height=\"162\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-2-300x162.png 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-2.png 306w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4365 aligncenter\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-3.jpg\" alt=\"\" width=\"225\" height=\"225\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-3.jpg 225w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-3-100x100.jpg 100w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-3-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-3-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83303-3-180x180.jpg 180w\" sizes=\"auto, (max-width: 225px) 100vw, 225px\" \/><\/p>\n<p><strong>HI83300 key characteristics been listed as below\u00a0<\/strong><\/p>\n<ul>\n<li>High Efficiency LED Light Source<\/li>\n<li>High Quality Narrow Band Interference Filters<\/li>\n<li>Reference Detector for a Stable Light Source<\/li>\n<li>Large Cuvette Size<\/li>\n<li>Focusing Lens for Greater Light Yield<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Key features of HI83300 ARE AS BELOW:<\/h3>\n<ul>\n<li>Advanced optical system with brighter, long-lasting LED light source<\/li>\n<li>Backlit 128 x 64 Pixel Graphic Liquid Crystal Display<\/li>\n<li>Built-in Reaction Timer for Photometric Measurements<\/li>\n<li>Absorbance mode &#8211; concentration versus absorbance<\/li>\n<li>Units of Measurement plus chemical form displayed<\/li>\n<li>Result conversion at the touch of a button<\/li>\n<li>Cuvette cover<\/li>\n<li>pH and temperature measurement with a single probe<\/li>\n<li>Good Laboratory Practice (GLP) &#8211; track calibration information including date, time, buffers used, offset and slope for traceability<\/li>\n<li>CAL Check alerts user to potential problems during the calibration process<\/li>\n<li>Data Logging &#8211; Up to 1000 photometric and pH readings can be stored<\/li>\n<li>Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs<\/li>\n<li>Battery Status Indicator<\/li>\n<li>Error Messages<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/section>\n<div id=\"specifications\" class=\"specification col-xs-12\">\n<article>\n<h2><\/h2>\n<p>To know <strong>HI83303 <a href=\"http:\/\/www.hannainst.com\" target=\"_blank\" rel=\"noopener\">HANNA<\/a> price<\/strong> or <strong>buy HI83303 Multiparameter<\/strong> <strong>Photometer<\/strong>, please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/p>\n<section>\n<h3><\/h3>\n<div class=\"table\">\n<div class=\"section-row section spec\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<h3>HI83303 Multiparameter Photometer Specifications:<\/h3>\n<table>\n<tbody>\n<tr>\n<td>Input Channels<\/td>\n<td><\/td>\n<td>1 pH electrode input and 5 photometer wavelengths<\/td>\n<\/tr>\n<tr>\n<td>pH Electrode<\/td>\n<td><\/td>\n<td>Digital pH electrode (not included)<\/td>\n<\/tr>\n<tr>\n<td>Loggin g type<\/td>\n<td><\/td>\n<td>Log on demand with user name and sample ID optional input<\/td>\n<\/tr>\n<tr>\n<td>Logging Memory<\/td>\n<td><\/td>\n<td>1000 readings<\/td>\n<\/tr>\n<tr>\n<td>Connectivity<\/td>\n<td><\/td>\n<td>USB-A host for flash drive; micro-USB-B for power and computer connectivity<\/td>\n<\/tr>\n<tr>\n<td>GLP<\/td>\n<td><\/td>\n<td>Calibration data for connected pH electrode<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td><\/td>\n<td>128 x 64 pixel LCD with backlight<\/td>\n<\/tr>\n<tr>\n<td>Battery Type\/Life<\/td>\n<td><\/td>\n<td>3.7 VDC Li-polymer rechargeable battery\/ &gt;500 photometric measurements or 50 hours of continuous pH measurement<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td><\/td>\n<td>5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)<\/td>\n<\/tr>\n<tr>\n<td>Environment<\/td>\n<td><\/td>\n<td>0 to 50.0\u00b0C (32 to 122.0\u00b0F; 0 to 95% RH, non-condensing<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td><\/td>\n<td>206 x 177 x 97mm (8.1 x 7.0 x 3.8&#8243;)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td><\/td>\n<td>1.0 kg (2.2lbs)<\/td>\n<\/tr>\n<tr>\n<td>Photometer\/Colorimeter Light Source<\/td>\n<td><\/td>\n<td>5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters<\/td>\n<\/tr>\n<tr>\n<td>Photometre\/Colorimeter Light Detector<\/td>\n<td><\/td>\n<td>Silicon Photodetector<\/td>\n<\/tr>\n<tr>\n<td>Bandpass filter Bandwidth<\/td>\n<td><\/td>\n<td>8nm<\/td>\n<\/tr>\n<tr>\n<td>Bandpass filter wavelength accruacy<\/td>\n<td><\/td>\n<td>+-1nm<\/td>\n<\/tr>\n<tr>\n<td>Cuvette Type<\/td>\n<td><\/td>\n<td>Round, 24.6mm<\/td>\n<\/tr>\n<tr>\n<td>Number of Methods<\/td>\n<td><\/td>\n<td>128 Max<\/td>\n<\/tr>\n<tr>\n<td>Ordering Information<\/td>\n<td><\/td>\n<td>HI-83303 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>ALKALINITY<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Alkalinity Range<\/td>\n<td><\/td>\n<td>Freshwater: 0 to 500 mg\/L (as CaCO<sub>3<\/sub>) Marine: 0 to 300 mg\/L (as CaCO<sub>3<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Alkalinity Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Alkalinity Accuracy<\/td>\n<td><\/td>\n<td>\u00b15 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Alkalinity Method<\/td>\n<td><\/td>\n<td>Colorimetric method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>AMMONIA<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Ammonia Range<\/td>\n<td><\/td>\n<td>Low Range: 0.00 to 3.00 mg\/L (as NH<sub>3<\/sub>-N) Medium Range: 0.00 to 10.00 mg\/L (as NH<sub>3<\/sub>-N) High Range: 0.0 to 100.0 mg\/L (as NH<sub>3<\/sub>-N)<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.04 mg\/L \u00b14% of reading Medium Range: \u00b10.05 mg\/L \u00b15% of reading High range: \u00b10.5 mg\/L \u00b15% of reading at 25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Method<\/td>\n<td><\/td>\n<td>Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CALCIUM<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Calcium Range<\/td>\n<td><\/td>\n<td>Freshwater: 0 to 400 mg\/L (as Ca<sub>2<\/sub>+) Marine: 200 to 600 mg\/L (as Ca<sub>2<\/sub>+)<\/td>\n<\/tr>\n<tr>\n<td>Calcium Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Calcium Accuracy<\/td>\n<td><\/td>\n<td>Freshwater: \u00b110 mg\/L \u00b15% of reading Marine: \u00b16% of reading<\/td>\n<\/tr>\n<tr>\n<td>Calcium Method<\/td>\n<td><\/td>\n<td>Freshwater: Adaptation of the Oxalate method Seawater: Adaptation of the Zincon method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CHLORINE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Free Chlorine Range<\/td>\n<td><\/td>\n<td>0.00 to 5.00 mg\/L (as Cl2)<\/td>\n<\/tr>\n<tr>\n<td>Free Chlorine Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Free Chlorine Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorine Range<\/td>\n<td><\/td>\n<td>0.00 to 5.00 mg\/L (as Cl<sub>2<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorine Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorine Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Method<\/td>\n<td><\/td>\n<td>Adaptation of the EPA 330.5 DPD method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>COPPER<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Copper Range<\/td>\n<td><\/td>\n<td>Low Range: 0.000 to 1.500 mg\/L (as Cu<sub>2<\/sub>+) High range: 0.00 to 5.00 mg\/L (as Cu<sub>2<\/sub>+)<\/td>\n<\/tr>\n<tr>\n<td>Copper Resolution<\/td>\n<td><\/td>\n<td>0.001 mg\/L; 0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Copper Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.01 mg\/L \u00b15% of reading High Range \u00b10.02 mg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Copper Method<\/td>\n<td><\/td>\n<td>Adaptation of the EPA bicinchoninate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>NITRATE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nitrate Range<\/td>\n<td><\/td>\n<td>0.0 to 30.0 mg\/L (as NO<sub>3<\/sub>&#8212; N)<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.5 mg\/L \u00b110% of reading<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Method<\/td>\n<td><\/td>\n<td>Adaptation of the cadmium reduction method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>NITRITE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nitrite Range<\/td>\n<td><\/td>\n<td>Freshwater Low Range: 0 to 600 \u03bcg\/L (as NO<sub>2<\/sub>&#8211;N) High Range: 0 to 150 mg\/L (as NO<sub>2<\/sub>-) Marine Ultra Low Range: 0 to 200 \u03bcg\/L (as NO<sub>2<\/sub>&#8211;N)<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Resolution<\/td>\n<td><\/td>\n<td>Freshwater: 1 \u03bcg\/L; 1 mg\/L Marine: 1 \u03bcg\/L<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Accuracy<\/td>\n<td><\/td>\n<td>Freshwater Low Range: \u00b120 \u03bcg\/L \u00b14% of reading High Range: \u00b14 mg\/L \u00b14% of reading Marine: \u00b110 \u03bcg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Method<\/td>\n<td><\/td>\n<td>Adaptation of the EPA Diazotization method 354.1; HR Ferrous Sulphate<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>OXYGEN, DISSOLVED<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Range<\/td>\n<td><\/td>\n<td>0.0 to 10.0 mg\/L (as O<sub>2<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.4 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>pH<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>pH Range<\/td>\n<td><\/td>\n<td>Photometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Resolution<\/td>\n<td><\/td>\n<td>Photometer: 0.1 pH pH electrode: 0.1 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Accuracy<\/td>\n<td><\/td>\n<td>Photometer: \u00b10.1 pH pH electrode: \u00b10.01 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Calibration<\/td>\n<td><\/td>\n<td>Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)<\/td>\n<\/tr>\n<tr>\n<td>pH Temperature Compensation<\/td>\n<td><\/td>\n<td>Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used<\/td>\n<\/tr>\n<tr>\n<td>pH CAL Check (electrode diagnostics)<\/td>\n<td><\/td>\n<td>clean electrode and check buffer\/check probe displayed during calibration<\/td>\n<\/tr>\n<tr>\n<td>pH Method<\/td>\n<td><\/td>\n<td>Photometer: phenol red<\/td>\n<\/tr>\n<tr>\n<td>pH-mV Range<\/td>\n<td><\/td>\n<td>\u00b11000 mV<\/td>\n<\/tr>\n<tr>\n<td>pH-mV Resolution<\/td>\n<td><\/td>\n<td>0.1 mV<\/td>\n<\/tr>\n<tr>\n<td>pH-mV Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.2 mV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>PHOSPHATE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Phosphate Range<\/td>\n<td><\/td>\n<td>Freshwater Low Range: 0.00 to 2.50 mg\/L (as PO<sub>4<\/sub><sup>3<\/sup>-) High range: 0.0 to 30.0 mg\/L (as PO<sub>4<\/sub><sup>3<\/sup>-) Seawater Ultra Low Range: 0 to 200 \u03bcg\/L (as P)<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Resolution<\/td>\n<td><\/td>\n<td>Freshwater: 0.01 mg\/L; 0.1 mg\/L Seawater: 1 \u03bcg\/L<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Accuracy<\/td>\n<td><\/td>\n<td>Freshwater Low Range: \u00b10.04 mg\/L \u00b14% of reading High Range: \u00b11 mg\/L \u00b14% of reading Seawater Ultra Low Range: \u00b15 \u03bcg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Method<\/td>\n<td><\/td>\n<td>Freshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>REAGENTS:<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Alkalinity<\/td>\n<td><\/td>\n<td>HI-775-26 for freshwater; HI-755-26 for saltwater<\/td>\n<\/tr>\n<tr>\n<td>Ammonia HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93733-01 (100 tests); HI-93733-03 (300 tests); MR &#8211; HI-93715-01 (100 tests); HI-93715-03 (300 tests); LR &#8211; HI-93700-01 (100 tests); HI-93700-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Calcium<\/td>\n<td><\/td>\n<td>HI-937521-01 (50 tests); HI-937521-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Calcium &#8211; Marine<\/td>\n<td><\/td>\n<td>HI-758-26<\/td>\n<\/tr>\n<tr>\n<td>Chlorine &#8211; Free<\/td>\n<td><\/td>\n<td>Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Total<\/td>\n<td><\/td>\n<td>HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)<\/td>\n<\/tr>\n<tr>\n<td>Copper \u2013 HR, total &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93702-01 (100 tests); HI-93702-03 (300 tests)<br \/>\nTotal copper &#8211; HI-93702T &#8211; 01 (100 tests); HI-93702T-03 (300 tests)<br \/>\nLR &#8211; HI-95747-01 (100 tests); HI-95747-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Nitrate<\/td>\n<td><\/td>\n<td>HI-93728-01 (100 tests); HI-93728-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Nitrite \u2013 HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93708-01 (100 tests); HI-93708-03 (300 tests)<br \/>\nLR &#8211; HI-93707-01 (100 tests); HI-93707-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Nitrite &#8211; ULR Marine<\/td>\n<td><\/td>\n<td>HI-764-25<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved (DO)<\/td>\n<td><\/td>\n<td>HI-93732-01 (100 tests); HI-93732-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>pH<\/td>\n<td><\/td>\n<td>HI-93710-01 (100 tests); HI-93710-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Phosphate &#8211; ULR Marine<\/td>\n<td><\/td>\n<td>HI-736-25<\/td>\n<\/tr>\n<tr>\n<td>Phosphate &#8211; HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93717-01 (100 tests); HI-93717-03 (300 tests)<br \/>\nLR &#8211; HI-93713-01 (100 tests); HI-93713-03 (300 tests)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/article>\n<\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>HI83303 Multiparameter Photometer<\/strong><\/p>\n[caption id=\"attachment_4362\" align=\"aligncenter\" width=\"300\"]<img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-4362\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303-300x300.jpg\" alt=\"HI83303 Multiparameter Photometer\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303-300x300.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303-100x100.jpg 100w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83303.jpg 400w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/> HI83303 Multiparameter Photometer[\/caption]\n<p>&nbsp;<\/p>\n<section>\n<article>\n<div class=\"section-row\">\n<div id=\"extended-description-tabs\" class=\"extended-description\">\n<div class=\"row\">\n<div id=\"description\" class=\"section-row section 1\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<h3>HI-83303 Aquaculture Photometer with pH meter<\/h3>\n<p>Advanced optical system &#8211; Unparalleled performance from a benchtop photometer.<\/p>\n<p>To save valuable benchtop space, the HI-83303 doubles as a professional pH meter with its digital pH\/temperature electrode input. Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/section>\n","protected":false},"featured_media":4362,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[89,83,65],"product_tag":[300,298,299],"class_list":["post-4361","product","type-product","status-publish","has-post-thumbnail","product_cat-bench-top-photometer","product_cat-benchtop-multiparameter","product_cat-multiparameter","product_tag-hi83303-hanna-specification","product_tag-hi83303-multiparameter-photometer","product_tag-hi83303-price","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4361","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4361"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4362"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4361"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product_brand?post=4361"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product_cat?post=4361"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product_tag?post=4361"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}