{"id":4367,"date":"2020-12-01T10:40:53","date_gmt":"2020-12-01T11:40:53","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4367"},"modified":"2025-08-16T07:04:14","modified_gmt":"2025-08-16T07:04:14","slug":"hi83399-multiparameter-with-cod-photometer","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi83399-multiparameter-with-cod-photometer\/","title":{"rendered":"HI83399 multiparameter with COD photometer"},"content":{"rendered":"<h2>8HI83399 multiparameter with COD photometer<\/h2>\n<div id=\"attachment_4368\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4368\" loading=\"lazy\" class=\"size-medium wp-image-4368\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399-300x300.jpg\" alt=\"HI83399 multiparameter with COD photometer\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399-300x300.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399-100x100.jpg 100w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-4368\" class=\"wp-caption-text\">HI83399 multiparameter with COD photometer<\/p><\/div>\n<p>The HI83399 is a benchtop multiparameter photometer that can measure COD and pH .<\/p>\n<p>The dimension of HI83399 is small and suitable for measuring the key water parameters and water quality control\u00a0 .The HI83399 measure by optical design.<\/p>\n<h3>HI-83399 Water and wastewater multi-parameter with COD photometer &amp; pH meter<\/h3>\n<p>HI83399 is proper device for using in water and wast water industry to measure\u00a040 key water and wastewater quality parameters with 73 different methods .<\/p>\n<div id=\"attachment_4369\" style=\"width: 235px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4369\" loading=\"lazy\" class=\"size-full wp-image-4369\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83399-1.jpg\" alt=\"HI83399 multiparameter with COD photometer\" width=\"225\" height=\"225\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83399-1.jpg 225w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83399-1-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83399-1-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83399-1-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83399-1-100x100.jpg 100w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><p id=\"caption-attachment-4369\" class=\"wp-caption-text\">HI83399 multiparameter with COD photometer<\/p><\/div>\n<p><img loading=\"lazy\" class=\"size-full wp-image-4370 aligncenter\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83399-2.jpg\" alt=\"\" width=\"300\" height=\"168\" \/><\/p>\n<section>\n<article>\n<div class=\"section-row\">\n<div id=\"extended-description-tabs\" class=\"extended-description\">\n<div class=\"row\">\n<div id=\"description\" class=\"section-row section 1\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<p>&nbsp;<\/p>\n<h3>HI88399 Key features been listed below:<\/h3>\n<ul>\n<li>Advanced optical system with brighter, long-lasting LED light source<\/li>\n<li>Backlit 128 x 64 Pixel Graphic Liquid Crystal Display<\/li>\n<li>Built-in Reaction Timer for Photometric Measurements<\/li>\n<li>Absorbance mode &#8211; concentration versus absorbance<\/li>\n<li>Units of Measurement plus chemical form displayed<\/li>\n<li>Result conversion at the touch of a button<\/li>\n<li>Cuvette cover<\/li>\n<li>pH and temperature measurement with a single probe<\/li>\n<li>Good Laboratory Practice (GLP) &#8211; track calibration information including date, time, buffers used, offset and slope for traceability<\/li>\n<li>CAL Check alerts user to potential problems during the calibration process<\/li>\n<li>Data Logging &#8211; Up to 1000 photometric and pH readings can be stored<\/li>\n<li>Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs<\/li>\n<li>Battery Status Indicator<\/li>\n<li>Error Messages<\/li>\n<\/ul>\n<\/div>\n<p><strong>HI83399 TOPIC characteristics been listed below:\u00a0<\/strong><\/p>\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<ul>\n<li>High Efficiency LED Light Source<\/li>\n<li>High Quality Narrow Band Interference Filters<\/li>\n<li>Reference Detector for a Stable Light Source<\/li>\n<li>Large Cuvette Size<\/li>\n<li>Focusing Lens for Greater Light Yield<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>To know <strong>HI83399 <a href=\"http:\/\/www.hannainst.com\">HANNA<\/a> price<\/strong> or <strong>buy HI83399 multiparameter with<\/strong> <strong>COD photometer<\/strong> , please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/section>\n<div id=\"specifications\" class=\"specification col-xs-12\">\n<article>\n<h2>Specifications<\/h2>\n<section>\n<h3>Specifications list<\/h3>\n<div class=\"table\">\n<div class=\"section-row section spec\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<h3>Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<td>Input Channels<\/td>\n<td><\/td>\n<td>1 pH electrode input and 5 photometer wavelengths<\/td>\n<\/tr>\n<tr>\n<td>pH Electrode<\/td>\n<td><\/td>\n<td>Digital pH electrode (not included)<\/td>\n<\/tr>\n<tr>\n<td>Logging type<\/td>\n<td><\/td>\n<td>Log on demand with user name and sample ID optional input<\/td>\n<\/tr>\n<tr>\n<td>Logging Memory<\/td>\n<td><\/td>\n<td>1000 readings<\/td>\n<\/tr>\n<tr>\n<td>Connectivity<\/td>\n<td><\/td>\n<td>USB-A host for flash drive; micro-USB-B for power and computer connectivity<\/td>\n<\/tr>\n<tr>\n<td>GLP<\/td>\n<td><\/td>\n<td>Calibration data for connected pH electrode<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td><\/td>\n<td>128 x 64 pixel LCD with backlight<\/td>\n<\/tr>\n<tr>\n<td>Battery Type\/Life<\/td>\n<td><\/td>\n<td>3.7 VDC Li-polymer rechargeable battery\/ &gt;500 photometric measurements or 50 hours of continuous pH measurement<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td><\/td>\n<td>5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)<\/td>\n<\/tr>\n<tr>\n<td>Environment<\/td>\n<td><\/td>\n<td>0 to 50.0\u00b0C (32 to 122.0\u00b0F; 0 to 95% RH, non-condensing<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td><\/td>\n<td>206 x 177 x 97mm (8.1 x 7.0 x 3.8&#8243;)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td><\/td>\n<td>1.0 kg (2.2lbs)<\/td>\n<\/tr>\n<tr>\n<td>Photometer\/Colorimeter Light Source<\/td>\n<td><\/td>\n<td>5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters<\/td>\n<\/tr>\n<tr>\n<td>Photometre\/Colorimeter Light Detector<\/td>\n<td><\/td>\n<td>Silicon Photodetector<\/td>\n<\/tr>\n<tr>\n<td>Bandpass filter Bandwidth<\/td>\n<td><\/td>\n<td>8nm<\/td>\n<\/tr>\n<tr>\n<td>Bandpass filter wavelength accruacy<\/td>\n<td><\/td>\n<td>+-1nm<\/td>\n<\/tr>\n<tr>\n<td>Cuvette Type<\/td>\n<td><\/td>\n<td>Round, 24.6mm<\/td>\n<\/tr>\n<tr>\n<td>Number of Methods<\/td>\n<td><\/td>\n<td>128 Max<\/td>\n<\/tr>\n<tr>\n<td>Ordering Information<\/td>\n<td><\/td>\n<td>HI-83399 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>ALKALINITY<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Alkalinity Range<\/td>\n<td><\/td>\n<td>Freshwater: 0 to 500 mg\/L (as CaCO<sub>3<\/sub>) Marine: 0 to 300 mg\/L (as CaCO<sub>3<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Alkalinity Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Alkalinity Accuracy<\/td>\n<td><\/td>\n<td>\u00b15 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Alkalinity Method<\/td>\n<td><\/td>\n<td>Bromocresol green method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>ALUMINIUM<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Aluminium Range<\/td>\n<td><\/td>\n<td>0.00 to 1.00 mg\/L (as Al<sub>3<\/sub>+)<\/td>\n<\/tr>\n<tr>\n<td>Aluminium Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Aluminium Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.04 mg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Aluminium Method<\/td>\n<td><\/td>\n<td>Adaptation of the aluminon method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>AMMONIA<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Ammonia Range<\/td>\n<td><\/td>\n<td>Low Range: 0.00 to 3.00 mg\/L (as NH<sub>3<\/sub>-N) Medium Range: 0.00 to 10.00 mg\/L (as NH<sub>3<\/sub>-N) High Range: 0.0 to 100.0 mg\/L (as NH<sub>3<\/sub>-N)<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.04 mg\/L \u00b14% of reading Medium Range: \u00b10.05 mg\/L \u00b15% of reading High range: \u00b10.5 mg\/L \u00b15% of reading at 25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Method<\/td>\n<td><\/td>\n<td>Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>BROMINE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Bromine Range<\/td>\n<td><\/td>\n<td>0.00 to 8.00 mg\/L (as Br<sub>2<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Bromine Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Bromine Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.08 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Bromine Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CALCIUM<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Calcium Range<\/td>\n<td><\/td>\n<td>Freshwater: 0 to 400 mg\/L (as Ca<sup>2+<\/sup>) Marine: 200 to 600 mg\/L (as Ca<sup>2+<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td>Calcium Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Calcium Accuracy<\/td>\n<td><\/td>\n<td>Freshwater: \u00b110 mg\/L \u00b15% of reading Marine: \u00b16% of reading<\/td>\n<\/tr>\n<tr>\n<td>Calcium Method<\/td>\n<td><\/td>\n<td>Freshwater: Adaptation of the Oxalate method Seawater: Adaptation of the Zincon method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CHLORIDE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Chloride Range<\/td>\n<td><\/td>\n<td>0.0 to 20.0 mg\/L (as Cl\u207b)<\/td>\n<\/tr>\n<tr>\n<td>Chloride Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Chloride Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.5 mg\/L \u00b16% of reading at 25 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CHLORINE DIOXIDE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Chlorine Dioxide Range<\/td>\n<td><\/td>\n<td>0.00 to 2.00 mg\/L (as ClO2)<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Dioxide Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Dioxide Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.10 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Dioxide Method<\/td>\n<td><\/td>\n<td>Adaptation of the Chlorophenol Red method.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CHLORINE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Free Chlorine Range<\/td>\n<td><\/td>\n<td>0.00 to 5.00 mg\/L (as Cl<sub>2<\/sub>) Ultra Low Range: 0.000 to 0.500 mg\/L (as Cl<sub>2<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Free Chlorine Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L Ultra Low Range: 0.001 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Free Chlorine Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.03 mg\/L \u00b13% of reading Ultra Low Range: \u00b10.020 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorine Range<\/td>\n<td><\/td>\n<td>0.00 to 5.00 mg\/L (as Cl<sub>2<\/sub>) Ultra Low Range: 0.000 to 0.500 mg\/L (as Cl<sub>2<\/sub>) Ultra High Range: 0 to 500 mg\/L (as Cl<sub>2<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorine Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L; 0.001 mg\/L; 1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorine Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.03 mg\/L \u00b13% of reading Ultra Low Range: \u00b10.020 mg\/L \u00b13% of reading Ultra High Range: \u00b13 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Method<\/td>\n<td><\/td>\n<td>Adaptation of the EPA 330.5 DPD method Free Chlorine (ULR) &amp; Total Chlorine (UHR): Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CHROMIUM, HEXAVALENT<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Chromium, Hexavalent Range<\/td>\n<td><\/td>\n<td>Low Range: 0 to 300 \u03bcg\/L (as Cr<sup>6+<\/sup>) High Range: 0 to 1000 \u03bcg\/L (as Cr<sup>6+<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td>Chromium, Hexavalent Resolution<\/td>\n<td><\/td>\n<td>1 \u03bcg\/L<\/td>\n<\/tr>\n<tr>\n<td>Chromium, Hexavalent Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b11 \u03bcg\/L \u00b14% of reading High Range: \u00b15 \u03bcg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Chromium, Hexavalent Method<\/td>\n<td><\/td>\n<td>Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>COD<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>COD Low, Medium &amp; High Range<\/td>\n<td><\/td>\n<td>Low Range: 0 to 150 mg\/L (as O<sub>2<\/sub>) Medium Range: 0 to 1500 mg\/L (as O<sub>2<\/sub>) High Range: 0 to 15000 mg\/L (as O<sub>2<\/sub><\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td><\/td>\n<td>1mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b15 mg\/L \u00b14% of reading Medium Range: \u00b115 mg\/L \u00b14% of reading High Range: \u00b1150 mg\/L or \u00b12% of reading<\/td>\n<\/tr>\n<tr>\n<td>Method<\/td>\n<td><\/td>\n<td>Low and medium range: dichromate mercury-free High Range: dichromate<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>COLOUR, WATER<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Colour, Water Range<\/td>\n<td><\/td>\n<td>0 to 500 PCU (Platinum Cobalt Units)<\/td>\n<\/tr>\n<tr>\n<td>Colour, Water Resolution<\/td>\n<td><\/td>\n<td>1 PCU<\/td>\n<\/tr>\n<tr>\n<td>Colour, Water Accuracy<\/td>\n<td><\/td>\n<td>\u00b110 PCU \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Colour, Water Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>COPPER<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Copper Range<\/td>\n<td><\/td>\n<td>Low Range: 0.000 to 1.500 mg\/L (as Cu<sup>2+<\/sup>) High range: 0.00 to 5.00 mg\/L (as Cu<sup>2+<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td>Copper Resolution<\/td>\n<td><\/td>\n<td>0.001 mg\/L; 0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Copper Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.01 mg\/L \u00b15% of reading High Range \u00b10.02 mg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Copper Method<\/td>\n<td><\/td>\n<td>Adaptation of the EPA bicinchoninate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CYANURIC ACID<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid Range<\/td>\n<td><\/td>\n<td>0 to 80 mg\/L (as CYA)<\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid Accuracy<\/td>\n<td><\/td>\n<td>\u00b11 mg\/L \u00b115% of reading<\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid Method<\/td>\n<td><\/td>\n<td>Adaptation of the turbidimetric method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>FLUORIDE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Fluoride Range<\/td>\n<td><\/td>\n<td>Low Range: 0.00 to 2.00 mg\/L (as F-) High range: 0.0 to 20.0 mg\/L (as F-)<\/td>\n<\/tr>\n<tr>\n<td>Fluoride Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Fluoride Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.03 mg\/L \u00b13% of reading High Range: \u00b10.5 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Fluoride Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>HARDNESS, CALCIUM<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Hardness, Calcium Range<\/td>\n<td><\/td>\n<td>0.00 to 2.70 mg\/L (as CaCO<sub>3<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Calcium Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Calcium Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.11 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Calcium Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>HARDNESS, MAGNESIUM<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Hardness, Magnesium Range<\/td>\n<td><\/td>\n<td>0.00 to 2.00 mg\/L (as CaCO<sub>3<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Magnesium Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Magnesium Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.11 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Magnesium Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method (Calmagite)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>HARDNESS, TOTAL<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Hardness, Total Range<\/td>\n<td><\/td>\n<td>Low Range: 0 to 250 mg\/L (as CaCO<sub>3<\/sub>) Medium Range: 200 to 500 mg\/L (as CaCO<sub>3<\/sub>) High Range: 400 to 750 mg\/L (as CaCO<sub>3<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Total Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Total Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b15 mg\/L \u00b14% of reading Medium Range: \u00b17 mg\/L \u00b13% of reading High Range: \u00b110 mg\/L \u00b12% of reading<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Total Method<\/td>\n<td><\/td>\n<td>Calmagite<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>HYDRAZINE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Hydrazine Range<\/td>\n<td><\/td>\n<td>0 to 400 \u03bcg\/L (as N<sub>2<\/sub>H<sub>4<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Hydrazine Resolution<\/td>\n<td><\/td>\n<td>1 \u03bcg\/L<\/td>\n<\/tr>\n<tr>\n<td>Hydrazine Accuracy<\/td>\n<td><\/td>\n<td>\u00b14% of full scale reading<\/td>\n<\/tr>\n<tr>\n<td>Hydrazine Method<\/td>\n<td><\/td>\n<td>Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>IODINE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Iodine Range<\/td>\n<td><\/td>\n<td>0.0 to 12.5 mg\/L (as I<sub>2<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Iodine Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Iodine Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.1 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Iodine Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>IRON<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Iron Range<\/td>\n<td><\/td>\n<td>Low Range: 0.000 to 1.600 mg\/L (as Fe) High Range: 0.00 to 5.00 mg\/L (as Fe)<\/td>\n<\/tr>\n<tr>\n<td>Iron Resolution<\/td>\n<td><\/td>\n<td>0.001 mg\/L; 0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Iron Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.01 mg\/L \u00b18% of reading High Range: \u00b10.04 mg\/L \u00b12% of reading<\/td>\n<\/tr>\n<tr>\n<td>Iron Method<\/td>\n<td><\/td>\n<td>Low Range: Adaptation of the TPTZ Method High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>MAGNESIUM<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Magnesium Range<\/td>\n<td><\/td>\n<td>0 to 150 mg\/L (as Mg2+)<\/td>\n<\/tr>\n<tr>\n<td>Magnesium Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Magnesium Accuracy<\/td>\n<td><\/td>\n<td>\u00b15 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Magnesium Method<\/td>\n<td><\/td>\n<td>Adaptation of the Calmagite method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>MANGANESE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Manganese Range<\/td>\n<td><\/td>\n<td>Low Range: 0 to 300 \u00b5g\/L (as Mn) High range: 0.0 to 20.0 mg\/L (as Mn)<\/td>\n<\/tr>\n<tr>\n<td>Manganese Resolution<\/td>\n<td><\/td>\n<td>1 \u00b5g\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Manganese Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b110 \u00b5g\/L \u00b13% of reading High Range: \u00b10.3 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Manganese Method<\/td>\n<td><\/td>\n<td>Low Range: Adaptation of the PAN Method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>MOLYBDENUM<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Molybdenum Range<\/td>\n<td><\/td>\n<td>0.0 to 40.0 mg\/L (as Mo<sup>6+<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td>Molybdenum Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Molybdenum Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.3 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Molybdenum Method<\/td>\n<td><\/td>\n<td>Adaptation of the mercaptoacetic acid method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>NICKEL<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nickel Range<\/td>\n<td><\/td>\n<td>Low Range: 0.000 to 1.000 mg\/L (as Ni) High Range: 0.00 to 7.00 g\/L (as Ni)<\/td>\n<\/tr>\n<tr>\n<td>Nickel Resolution<\/td>\n<td><\/td>\n<td>0.001 mg\/L; 0.01 g\/L<\/td>\n<\/tr>\n<tr>\n<td>Nickel Accuracy<\/td>\n<td><\/td>\n<td>Low range: \u00b10.010 mg\/L \u00b17% of reading High Range: \u00b10.07 g\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Nickel Method<\/td>\n<td><\/td>\n<td>Low Range: Adaptation of the PAN method High Range: Adaptation of the photometric method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>NITRATE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nitrate Range<\/td>\n<td><\/td>\n<td>0.0 to 30.0 mg\/L (as NO<sub>3<\/sub>&#8212; N)<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.5 mg\/L \u00b110% of reading<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Method<\/td>\n<td><\/td>\n<td>Adaptation of the cadmium reduction method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>NITRITE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nitrite Range<\/td>\n<td><\/td>\n<td>Freshwater Low Range: 0 to 600 \u03bcg\/L (as NO<sub>2<\/sub>&#8211;N) High Range: 0 to 150 mg\/L (as NO<sub>2<\/sub>-) Marine Ultra Low Range: 0 to 200 \u03bcg\/L (as NO<sub>2<\/sub>&#8211;N)<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Resolution<\/td>\n<td><\/td>\n<td>Freshwater: 1 \u03bcg\/L; 1 mg\/L Marine: 0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Accuracy<\/td>\n<td><\/td>\n<td>Freshwater Low Range: \u00b120 \u03bcg\/L \u00b14% of reading High Range: \u00b14 mg\/L \u00b14% of reading Marine: \u00b10.5 mg\/L \u00b110% of reading<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Method<\/td>\n<td><\/td>\n<td>Adaptation of the EPA Diazotization method 354.1; HR Ferrous Sulphate; Cadium Reduction<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>NITROGEN<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nitrogen, Total Low &amp; High Range<\/td>\n<td><\/td>\n<td>Total Low Range: 0.0 to 25.0 mg\/L (as NO<sub>3<\/sub><sup>&#8211;<\/sup>-N) High Range: 0 to 150 mg\/L (as N)<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td><\/td>\n<td>1mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b11.0 mg\/L \u00b15% of reading High Range: \u00b13 mg\/L or \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Method<\/td>\n<td><\/td>\n<td>Chromotropic acid<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>OXYGEN, DISSOLVED<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Range<\/td>\n<td><\/td>\n<td>0.0 to 10.0 mg\/L (as O<sub>2<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.4 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>OXYGEN, SCAVENGER<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Scavenger Range<\/td>\n<td><\/td>\n<td>0 to 1000 \u03bcg\/L (as DEHA) 0.00 to 1.50 mg\/L (as Carbohydrazide) 0.00 to 2.50 mg\/L (as Hydroquinone) 0.00 to 4.50 mg\/L (as ISO-ascorbic acid)<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Scavenger Resolution<\/td>\n<td><\/td>\n<td>1 \u03bcg\/L (DEHA); 0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Scavenger Accuracy<\/td>\n<td><\/td>\n<td>\u00b15 \u03bcg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Scavenger Method<\/td>\n<td><\/td>\n<td>Adaptation of the iron reduction method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>OZONE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Ozone Range<\/td>\n<td><\/td>\n<td>0.00 to 2.00 mg\/L (as O<sub>3<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Ozone Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Ozone Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.02 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Ozone Method<\/td>\n<td><\/td>\n<td>Colorimetric DPD Method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>pH<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>pH Range<\/td>\n<td><\/td>\n<td>6.5 to 8.5 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Resolution<\/td>\n<td><\/td>\n<td>0.1 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.1 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Method<\/td>\n<td><\/td>\n<td>phenol red<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>PHOSPHATE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Phosphate Range<\/td>\n<td><\/td>\n<td>Freshwater Low Range: 0.00 to 2.50 mg\/L (as PO<sub>4<\/sub><sup>3-<\/sup>) High range: 0.0 to 30.0 mg\/L (as PO<sub>4<\/sub><sup>3-<\/sup>) Seawater Ultra Low Range: 0 to 200 \u03bcg\/L (as P)<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Resolution<\/td>\n<td><\/td>\n<td>Freshwater: 0.01 mg\/L; 0.1 mg\/L Seawater: 1 \u03bcg\/L<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Accuracy<\/td>\n<td><\/td>\n<td>Freshwater Low Range: \u00b10.04 mg\/L \u00b14% of reading High Range: \u00b11 mg\/L \u00b14% of reading Seawater Ultra Low Range: \u00b15 \u03bcg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Method<\/td>\n<td><\/td>\n<td>Freshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>POTASSIUM<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Potassium Range<\/td>\n<td><\/td>\n<td>0.0 to 20.0 mg\/L (as K)<\/td>\n<\/tr>\n<tr>\n<td>Potassium Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Potassium Accuracy<\/td>\n<td><\/td>\n<td>\u00b13.0 mg\/L \u00b17% of reading<\/td>\n<\/tr>\n<tr>\n<td>Potassium Method<\/td>\n<td><\/td>\n<td>Adaptation of the Turbidimetric Tetraphenylborate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>SILICA<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Silica Range<\/td>\n<td><\/td>\n<td>Low Range: 0.00 to 2.00 mg\/L (as SiO<sub>2<\/sub>) High Range: 0 to 200 mg\/L (as SiO<sub>2<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td>Silica Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L; 1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Silica Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.03 mg\/L \u00b13% of reading High Range: \u00b11 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Silica Method<\/td>\n<td><\/td>\n<td>Low Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method High Range: Adaptation of the USEPA Method 370.1 and Standard Method 4500-SiO<sub>2<\/sub><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>SILVER<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Silver Range<\/td>\n<td><\/td>\n<td>0.000 to 1.000 mg\/L (as Ag)<\/td>\n<\/tr>\n<tr>\n<td>Silver Resolution<\/td>\n<td><\/td>\n<td>0.001 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Silver Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.020 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Silver Method<\/td>\n<td><\/td>\n<td>Adaptation of the PAN method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>SULPHATE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Sulphate Range<\/td>\n<td><\/td>\n<td>0 to 150 mg\/L (as SO<sub>4<\/sub><sup>2<\/sup>-)<\/td>\n<\/tr>\n<tr>\n<td>Sulphate Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Sulphate Accuracy<\/td>\n<td><\/td>\n<td>\u00b15 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Sulphate Method<\/td>\n<td><\/td>\n<td>Turbidimetric &#8211; Sulphate is precipitated with barium chloride crystals<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>SURFACTANTS, ANIONIC<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td><\/td>\n<td>0.0 to 3.50 mg\/L (as SDBS)<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td><\/td>\n<td>0.01mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.04 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Method<\/td>\n<td><\/td>\n<td>Methylene blue<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>ZINC<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Zinc Range<\/td>\n<td><\/td>\n<td>0.00 to 3.00 mg\/L (as Zn)<\/td>\n<\/tr>\n<tr>\n<td>Zinc Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Zinc Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Zinc Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>REAGENTS<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Alkalinity<\/td>\n<td><\/td>\n<td>HI-93755-01 (100 tests); HI-93755-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Aluminium<\/td>\n<td><\/td>\n<td>HI-93712-01 (100 tests); HI-93712-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Ammonia HR, MR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93733-01 (100 tests); HI-93733-03 (300 tests); MR &#8211; HI-93715-01 (100 tests); HI-93715-03 (300 tests); LR &#8211; HI-93700-01 (100 tests); HI-93700-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Bromine<\/td>\n<td><\/td>\n<td>HI-93716-01 (100 tests); HI-93716-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Calcium<\/td>\n<td><\/td>\n<td>HI-937521-01 (50 tests); HI-937521-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Calcium and Magnesium<\/td>\n<td><\/td>\n<td>HI-93752-01 (50 x 2 tests) HI-93752-03 (150 x 2 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chloride<\/td>\n<td><\/td>\n<td>HI-93753-01 (100 tests); HI-93753-03 (300 Tests)<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Dioxide<\/td>\n<td><\/td>\n<td>Reagents: HI-93738-01 (100 tests); HI-93738-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chlorine &#8211; Free<\/td>\n<td><\/td>\n<td>Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chlorine UHR<\/td>\n<td><\/td>\n<td>HI-95771-01 (100 tests); HI-95771-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chlorine, Free and Total HR<\/td>\n<td><\/td>\n<td>HI-93734-01 (100 tests); HI-93734-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chlorine, Free ULR<\/td>\n<td><\/td>\n<td>HI-95762-01 (100 tests); HI-95762-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Total<\/td>\n<td><\/td>\n<td>HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)<br \/>\nChlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chromium VI \u2013 HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93723-01 (100 tests); HI-93723-03 (300 tests)<br \/>\nLR &#8211; HI-93749-01 (100 tests); HI-93749-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Copper \u2013 HR, total &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93702-01 (100 tests); HI-93702-03 (300 tests)<br \/>\nTotal copper &#8211; HI-93702T &#8211; 01 (100 tests); HI-93702T-03 (300 tests)<br \/>\nLR &#8211; HI-95747-01 (100 tests); HI-95747-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Cyanide<\/td>\n<td><\/td>\n<td>HI-93714-01 (100 tests); HI-93714-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid<\/td>\n<td><\/td>\n<td>HI-93722-01 (100 tests); HI-93722-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Detergents, Anionic<\/td>\n<td><\/td>\n<td>HI-95769-01 (40 tests)<\/td>\n<\/tr>\n<tr>\n<td>Fluoride \u2013 HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93739-01 (100 tests); HI-93739-03 (300 tests)<br \/>\nLR &#8211; HI-93729-01 (100 tests); HI-93729-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Glycine Powder<\/td>\n<td><\/td>\n<td>HI-93703-52 (100 tests)<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Calcium<\/td>\n<td><\/td>\n<td>HI-93720-01 (100 tests); HI-93720-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Magnesium and total hardness<\/td>\n<td><\/td>\n<td>HI-93719-01 (100 tests); HI-93719-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Hardness, total HR, MR, LR and Total LR+MR+LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93735-02 (100 tests); MR &#8211; HI-93735-01 (100 tests); LR &#8211; HI-93735-00 (100 tests); HR MR &amp;LR &#8211; HI-93735-0 (100 x 3 tests)<\/td>\n<\/tr>\n<tr>\n<td>Hydrazine<\/td>\n<td><\/td>\n<td>HI-93704-01 (100 tests); HI-93704-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Iodine<\/td>\n<td><\/td>\n<td>HI-93718-01 (100 tests); HI-93718-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Iron \u2013 HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93721-01 (100 tests); HI-93721-03 (300 tests)<br \/>\nLR &#8211; HI-93746-01 (100 tests); HI-93746-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Manganese \u2013 HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93709-01 (100 tests); HI-93709-03 (300 tests)<br \/>\nLR &#8211; HI-93748-01 (50 tests); HI-93748-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Magnesium<\/td>\n<td><\/td>\n<td>HI-937520-01 (50 tests); HI-937520-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Molybdenum<\/td>\n<td><\/td>\n<td>HI-93730-01 (100 tests); HI-93730-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Nickel &#8211; HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93726-01 (100 tests); HI-93726-03 (300 tests)<br \/>\nLR &#8211; HI-93740-01 (50 tests); HI-93740-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Nitrate<\/td>\n<td><\/td>\n<td>HI-93728-01 (100 tests); HI-93728-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Nitrite \u2013 HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93708-01 (100 tests); HI-93708-03 (300 tests)<br \/>\nLR &#8211; HI-93707-01 (100 tests); HI-93707-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved (DO)<\/td>\n<td><\/td>\n<td>HI-93732-01 (100 tests); HI-93732-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Ozone<\/td>\n<td><\/td>\n<td>HI-93757-01 (100 tests); HI-93757-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>pH<\/td>\n<td><\/td>\n<td>HI-93710-01 (100 tests); HI-93710-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Phosphate &#8211; HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-93717-01 (100 tests); HI-93717-03 (300 tests)<br \/>\nLR &#8211; HI-93713-01 (100 tests); HI-93713-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Phosphorus<\/td>\n<td><\/td>\n<td>HI-93706-01 (100 tests); HI-93706-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Potassium<\/td>\n<td><\/td>\n<td>HI-93750-01 (100 tests); HI-93750-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Silica \u2013 HR &amp; LR<\/td>\n<td><\/td>\n<td>HR &#8211; HI-96770-01 (100 tests); HI-96770-03 (300 tests)<br \/>\nLR &#8211; HI-93705-01 (100 tests); HI-93705-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Silver<\/td>\n<td><\/td>\n<td>HI-93737-01 (50 tests); HI-93737-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Sulphate<\/td>\n<td><\/td>\n<td>HI-93751-01 (100 tests); HI-93751-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Zinc<\/td>\n<td><\/td>\n<td>HI-93731-01 (100 tests); HI-93731-03 (300 tests)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/article>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>HI83399 multiparameter with COD photometer<\/p>\n[caption id=\"attachment_4368\" align=\"aligncenter\" width=\"300\"]<img loading=\"lazy\" class=\"size-medium wp-image-4368\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399-300x300.jpg\" alt=\"HI83399 multiparameter with COD photometer\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399-300x300.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399-100x100.jpg 100w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83399.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> HI83399 multiparameter with COD photometer[\/caption]\n<h3>HI-83399 Water and wastewater multi-parameter with COD photometer &amp; pH meter<\/h3>\n<p>One meter can be used for both photometric and pH measurements. HI-83399 is a compact, multi-parameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available, with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and imperfections in the glass cuvette.<\/p>\n","protected":false},"featured_media":4368,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4367"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4367"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4368"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4367"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}