{"id":4372,"date":"2020-12-01T11:29:23","date_gmt":"2020-12-01T12:29:23","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4372"},"modified":"2021-04-27T14:34:43","modified_gmt":"2021-04-27T14:34:43","slug":"hi83300-multiparameter-photometer","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi83300-multiparameter-photometer\/","title":{"rendered":"HI83300 Multiparameter Photometer"},"content":{"rendered":"<h2>HI83300 Multiparameter Photometer<\/h2>\n<div id=\"attachment_4373\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4373\" loading=\"lazy\" class=\"size-full wp-image-4373\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83300-1-300x300-1.jpg\" alt=\"HI83300 Multiparameter Photometer\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83300-1-300x300-1.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83300-1-300x300-1-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83300-1-300x300-1-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83300-1-300x300-1-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83300-1-300x300-1-100x100.jpg 100w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-4373\" class=\"wp-caption-text\">HI83300 Multiparameter Photometer<\/p><\/div>\n<p>HI83300 is a benchtop photometer and useful device for most of laboratories whom are looking to measure most of water parameters .<\/p>\n<p>&nbsp;<\/p>\n<div id=\"attachment_4377\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4377\" loading=\"lazy\" class=\"size-medium wp-image-4377\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83300-x-300x107.jpg\" alt=\"HI83300 Multiparameter Photometer\" width=\"300\" height=\"107\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83300-x-300x107.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83300-x.jpg 376w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-4377\" class=\"wp-caption-text\">HI83300 Multiparameter Photometer<\/p><\/div>\n<div class=\"product-view__product-essential__product-shop__ask-question\"><\/div>\n<div class=\"product-view__product-essential__product-shop__table\">\n<div class=\"table-row\">\n<div class=\"title\"><i class=\"fa fa-info-circle\" aria-hidden=\"true\"><\/i><\/div>\n<div class=\"title\">HI83300 is multiparameter photomer and Ph meter that can measure 37 key water quality parameters via optical method.<\/div>\n<\/div>\n<div class=\"table-row\">\n<div class=\"title\"><i class=\"fa fa-info-circle\" aria-hidden=\"true\"><\/i>HI83300 is ex termly small . its similar to portable and bench top device both.<\/div>\n<div><\/div>\n<\/div>\n<\/div>\n<div class=\"product-view__product-essential__product-shop__ask-question\"><span style=\"font-size: 20px; font-weight: 600;\">below is some characters of HI83300:<\/span><\/div>\n<section>\n<article>\n<div class=\"section-row\">\n<div id=\"extended-description-tabs\" class=\"extended-description\">\n<div class=\"row\">\n<div id=\"description\" class=\"section-row section 1\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<ul>\n<li>High Efficiency LED Light Source<\/li>\n<\/ul>\n<ul>\n<li>High Quality Narrow Band Interference Filters<\/li>\n<li>Reference Detector for a Stable Light Source<\/li>\n<li>Large Cuvette Size<\/li>\n<\/ul>\n<ul>\n<li>Focusing Lens for Greater Light Yield<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Key features OF hi83300 been listed :<\/h3>\n<ul>\n<li>Advanced optical system with brighter, long-lasting LED light source<\/li>\n<li>Backlit 128 x 64 Pixel Graphic Liquid Crystal Display<\/li>\n<li>Built-in Reaction Timer for Photometric Measurements<\/li>\n<li>Absorbance mode &#8211; concentration versus absorbance<\/li>\n<li>Units of Measurement plus chemical form displayed<\/li>\n<li>Result conversion at the touch of a button<\/li>\n<li>Cuvette cover<\/li>\n<li>pH and temperature measurement with a single probe<\/li>\n<li>Good Laboratory Practice (GLP) &#8211; track calibration information including date, time, buffers used, offset and slope for traceability<\/li>\n<li>CAL Check alerts user to potential problems during the calibration process<\/li>\n<li>Data Logging &#8211; Up to 1000 photometric and pH readings can be stored<\/li>\n<li>Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs<\/li>\n<li>Battery Status Indicator<\/li>\n<li>Error Messages<\/li>\n<\/ul>\n<div id=\"attachment_4376\" style=\"width: 300px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4376\" loading=\"lazy\" class=\"size-full wp-image-4376\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83300-3.jpg\" alt=\"HI83300 Multiparameter Photometer\" width=\"290\" height=\"174\" \/><p id=\"caption-attachment-4376\" class=\"wp-caption-text\">HI83300 Multiparameter Photometer<\/p><\/div>\n<div id=\"attachment_4375\" style=\"width: 285px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4375\" loading=\"lazy\" class=\"size-full wp-image-4375\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83300-2.jpg\" alt=\"HI83300 Multiparameter Photometer\" width=\"275\" height=\"183\" \/><p id=\"caption-attachment-4375\" class=\"wp-caption-text\">HI83300 Multiparameter Photometer<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_4374\" style=\"width: 235px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4374\" loading=\"lazy\" class=\"size-full wp-image-4374\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83300-1.jpg\" alt=\"HI83300 Multiparameter Photometer\" width=\"225\" height=\"225\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83300-1.jpg 225w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83300-1-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83300-1-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83300-1-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83300-1-100x100.jpg 100w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><p id=\"caption-attachment-4374\" class=\"wp-caption-text\">HI83300 Multiparameter Photometer<\/p><\/div>\n<p>To know <strong>HI83300 <a href=\"http:\/\/www.hannainst.com\">HANNA<\/a> price<\/strong> or <strong>buy HI83300 Multiparameter<\/strong> <strong>photometer<\/strong> , please contact <a href=\"http:\/\/www.sa-aia.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/section>\n<div id=\"specifications\" class=\"specification col-xs-12\">\n<article>\n<h2>Specifications<\/h2>\n<section>\n<h3>Specifications list<\/h3>\n<div class=\"table\">\n<div class=\"section-row section spec\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<h3>Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<td>GENERAL<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>MEASUREMENT CHANNELS<\/td>\n<td><\/td>\n<td>5 X OPTICAL CHANNELS; 1 X SMART ELECTRODE CHANNEL (pH MEASUREMENT)<\/td>\n<\/tr>\n<tr>\n<td>Absorbance Range<\/td>\n<td><\/td>\n<td>0.000Abs-4.000Abs<\/td>\n<\/tr>\n<tr>\n<td>Absorbance Resolution<\/td>\n<td><\/td>\n<td>0.001 Abs<\/td>\n<\/tr>\n<tr>\n<td>Absorbance Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.003 Abs (at 1.000 Abs)<\/td>\n<\/tr>\n<tr>\n<td>Absorbance Light Source<\/td>\n<td><\/td>\n<td>Light-emitting diode<\/td>\n<\/tr>\n<tr>\n<td>Absorbance Bandpass Filter Bandwidth<\/td>\n<td><\/td>\n<td>8nm<\/td>\n<\/tr>\n<tr>\n<td>Absorbance Bandpass Filter Wavelength Accuracy<\/td>\n<td><\/td>\n<td>\u00b11.0nm<\/td>\n<\/tr>\n<tr>\n<td>Light Detector<\/td>\n<td><\/td>\n<td>Silicon photocell<\/td>\n<\/tr>\n<tr>\n<td>Cuvette Type<\/td>\n<td><\/td>\n<td>round, 24.6 mm diameter<\/td>\n<\/tr>\n<tr>\n<td>Number of Methods<\/td>\n<td><\/td>\n<td>128 max<\/td>\n<\/tr>\n<tr>\n<td>pH Range<\/td>\n<td><\/td>\n<td>-2.00 to 16.00 pH (\u00b11000mV)*<\/td>\n<\/tr>\n<tr>\n<td>pH Resolution<\/td>\n<td><\/td>\n<td>0.01 pH (0.01 mV)*<\/td>\n<\/tr>\n<tr>\n<td>Temperature Compensation<\/td>\n<td><\/td>\n<td>ATC (-5.0 to 100.0\u00b0C;*)<\/td>\n<\/tr>\n<tr>\n<td>Additional Specifications:<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Logging<\/td>\n<td><\/td>\n<td>1000 readings (mixed photometer and electrode)<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td><\/td>\n<td>128 x 64 pixel B\/W LCD with backlight<\/td>\n<\/tr>\n<tr>\n<td>USB-A (host) functions<\/td>\n<td><\/td>\n<td>mass-storage host<\/td>\n<\/tr>\n<tr>\n<td>USB-B ( Device) Functions<\/td>\n<td><\/td>\n<td>power input, mass-storage device<\/td>\n<\/tr>\n<tr>\n<td>Battery Life<\/td>\n<td><\/td>\n<td>&gt;500 Photometer measurements, or 50 hours of continuous pH measurement<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td><\/td>\n<td>5 VDC USB 2.0 power adapter\/ type micro-B connector 3.7 VDC Li-polymer rechargeable battery, non-serviceable<\/td>\n<\/tr>\n<tr>\n<td>Environment<\/td>\n<td><\/td>\n<td>0 to 50\u00b0C; 0 to 95% RH, non-condensing<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td><\/td>\n<td>206 x 177 x 97mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td><\/td>\n<td>1.0kg<\/td>\n<\/tr>\n<tr>\n<td>Ordering Information<\/td>\n<td><\/td>\n<td>HI-83300 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.<\/td>\n<\/tr>\n<tr>\n<td>*Limits will be reduced to actual sensor limits<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>ABSORBANCE<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Absorbance Range<\/td>\n<td><\/td>\n<td>0.000 to 4.000 Abs<\/td>\n<\/tr>\n<tr>\n<td>Absorbance Resolution<\/td>\n<td><\/td>\n<td>0.001 Abs<\/td>\n<\/tr>\n<tr>\n<td>Absorbance Accuracy<\/td>\n<td><\/td>\n<td>+\/-0.003Abs @ 1.000 Abs<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>ALKALINITY<\/td>\n<td><\/td>\n<td>Reagents &#8211; HI-93755-01 (100 tests); HI-93755-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Alkalinity Range<\/td>\n<td><\/td>\n<td>Freshwater: 0 to 500 mg\/L (as CaCO3) Marine: 0 to 300 mg\/L (as CaCO3)<\/td>\n<\/tr>\n<tr>\n<td>Alkalinity Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Alkalinity Accuracy<\/td>\n<td><\/td>\n<td>\u00b15 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Alkalinity Method<\/td>\n<td><\/td>\n<td>Colorimetric method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>ALUMINIUM<\/td>\n<td><\/td>\n<td>Reagents &#8211; HI-93712-01 (100 tests); HI-93712-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Aluminium Range<\/td>\n<td><\/td>\n<td>0.00 to 1.00 mg\/L (as Al3+)<\/td>\n<\/tr>\n<tr>\n<td>Aluminium Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Aluminium Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.04 mg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Aluminium Method<\/td>\n<td><\/td>\n<td>Adaptation of the aluminon method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>AMMONIA<\/td>\n<td><\/td>\n<td>Reagents: HR &#8211; HI-93733-01 (100 tests); HI-93733-03 (300 tests)<br \/>\nMR &#8211; HI-93715-01 (100 tests); HI-93715-03 (300 tests)<br \/>\nLR &#8211; HI-93700-01 (100 tests); HI-93700-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Range<\/td>\n<td><\/td>\n<td>Low Range: 0.00 to 3.00 mg\/L (as NH3-N) Medium Range: 0.00 to 10.00 mg\/L (as NH3-N) High Range: 0.0 to 100.0 mg\/L (as NH3-N)<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.04 mg\/L \u00b14% of reading Medium Range: \u00b10.05 mg\/L \u00b15% of reading High range: \u00b10.5 mg\/L \u00b15% of reading at 25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ammonia Method<\/td>\n<td><\/td>\n<td>Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>ANIONIC SURFACTANTS<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Anionic Surfactants Range<\/td>\n<td><\/td>\n<td>0.00 to 3.50 mg\/L (as SDBS)<\/td>\n<\/tr>\n<tr>\n<td>Anionic Surfactants Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Anionic Surfactants Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.04 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Anionic Surfactants Method<\/td>\n<td><\/td>\n<td>Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>BROMINE<\/td>\n<td><\/td>\n<td>Reagents: HI-93716-01 (100 tests); HI-93716-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Bromine Range<\/td>\n<td><\/td>\n<td>0.00 to 8.00 mg\/L (as Br2)<\/td>\n<\/tr>\n<tr>\n<td>Bromine Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Bromine Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.08 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Bromine Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CALCIUM<\/td>\n<td><\/td>\n<td>Reagents: HI-937521-01 (50 tests); HI-937521-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Calcium Range<\/td>\n<td><\/td>\n<td>Freshwater: 0 to 400 mg\/L (as Ca2+) Seawater: 200 to 600 mg\/L (as Ca2+)<\/td>\n<\/tr>\n<tr>\n<td>Calcium Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Calcium Accuracy<\/td>\n<td><\/td>\n<td>Freshwater: \u00b110 mg\/L \u00b15% of reading Seawater: \u00b16% of reading<\/td>\n<\/tr>\n<tr>\n<td>Calcium Method<\/td>\n<td><\/td>\n<td>Freshwater: Adaptation of the Oxalate method Seawater: Adaptation of the Zincon method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CHLORIDE<\/td>\n<td><\/td>\n<td>Reagents: HI-93753-01 (100 tests); HI-93753-03 (300 Tests)<\/td>\n<\/tr>\n<tr>\n<td>Chloride Range<\/td>\n<td><\/td>\n<td>0.0 to 20.0 mg\/L (as Cl\u207b)<\/td>\n<\/tr>\n<tr>\n<td>Chloride Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Chloride Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.5 mg\/L \u00b16% of reading at 25 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CHLORINE DIOXIDE<\/td>\n<td><\/td>\n<td>Reagents: HI-93738-01 (100 tests); HI-93738-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Dioxide Range<\/td>\n<td><\/td>\n<td>0.00 to 2.00 mg\/L (as ClO2)<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Dioxide Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Dioxide Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.10 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Dioxide Method<\/td>\n<td><\/td>\n<td>Adaptation of the Chlorophenol Red method.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CHLORINE<\/td>\n<td><\/td>\n<td>Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)<br \/>\nChlorine UHR Reagents: HI-95771-01 (100 tests); HI-95771-03 (300 tests)<br \/>\nChlorine, Free and Total HR: HI-93734-01 (100 tests); HI-93734-03 (300 tests)<br \/>\nChlorine, Free ULR: HI-95762-01 (100 tests); HI-95762-03 (300 tests)<br \/>\nChlorine Total: HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)<br \/>\nChlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Free Chlorine Range<\/td>\n<td><\/td>\n<td>0.00 to 5.00 mg\/L (as Cl2) Ultra Low Range: 0.000 to 0.500 mg\/L (as Cl2)<\/td>\n<\/tr>\n<tr>\n<td>Free Chlorine Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L Ultra Low Range: 0.001 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Free Chlorine Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.03 mg\/L \u00b13% of reading Ultra Low Range: \u00b10.020 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorine Range<\/td>\n<td><\/td>\n<td>0.00 to 5.00 mg\/L (as Cl2) Ultra Low Range: 0.000 to 0.500 mg\/L (as Cl2) Ultra High Range: 0 to 500 mg\/L (as Cl2)<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorine Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L; 0.001 mg\/L; 1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorine Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.03 mg\/L \u00b13% of reading Ultra Low Range: \u00b10.020 mg\/L \u00b13% of reading Ultra High Range: \u00b13 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Chlorine Method<\/td>\n<td><\/td>\n<td>Adaptation of the EPA 330.5 DPD method Free Chlorine (ULR) &amp; Total Chlorine (UHR): Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CHROMIUM, HEXAVALENT<\/td>\n<td><\/td>\n<td>Reagents: HR &#8211; HI-93723-01 (100 tests); HI-93723-03 (300 tests)<br \/>\nLR &#8211; HI-93749-01 (100 tests); HI-93749-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Chromium, Hexavalent Range<\/td>\n<td><\/td>\n<td>Low Range: 0 to 300 \u03bcg\/L (as Cr6+) High Range: 0 to 1000 \u03bcg\/L (as Cr6+)<\/td>\n<\/tr>\n<tr>\n<td>Chromium, Hexavalent Resolution<\/td>\n<td><\/td>\n<td>1 \u03bcg\/L<\/td>\n<\/tr>\n<tr>\n<td>Chromium, Hexavalent Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b11 \u03bcg\/L \u00b14% of reading High Range: \u00b15 \u03bcg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Chromium, Hexavalent Method<\/td>\n<td><\/td>\n<td>Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>COLOUR, WATER<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Colour, Water Range<\/td>\n<td><\/td>\n<td>0 to 500 PCU (Platinum Cobalt Units)<\/td>\n<\/tr>\n<tr>\n<td>Colour, Water Resolution<\/td>\n<td><\/td>\n<td>1 PCU<\/td>\n<\/tr>\n<tr>\n<td>Colour, Water Accuracy<\/td>\n<td><\/td>\n<td>\u00b110 PCU \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Colour, Water Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>COPPER<\/td>\n<td><\/td>\n<td>Reagents: HR &#8211; HI-93702-01 (100 tests); HI-93702-03 (300 tests)<br \/>\nTotal copper &#8211; HI-93702T &#8211; 01 (100 tests); HI-93702T-03 (300 tests)<br \/>\nLR &#8211; HI-95747-01 (100 tests); HI-95747-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Copper Range<\/td>\n<td><\/td>\n<td>Low Range: 0.000 to 1.500 mg\/L (as Cu2+) High range: 0.00 to 5.00 mg\/L (as Cu2+)<\/td>\n<\/tr>\n<tr>\n<td>Copper Resolution<\/td>\n<td><\/td>\n<td>0.001 mg\/L; 0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Copper Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.01 mg\/L \u00b15% of reading High Range \u00b10.02 mg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Copper Method<\/td>\n<td><\/td>\n<td>Adaptation of the EPA bicinchoninate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>CYANURIC ACID<\/td>\n<td><\/td>\n<td>Reagents: HI-93722-01 (100 tests); HI-93722-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid Range<\/td>\n<td><\/td>\n<td>0 to 80 mg\/L (as CYA)<\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid Accuracy<\/td>\n<td><\/td>\n<td>\u00b11 mg\/L \u00b115% of reading<\/td>\n<\/tr>\n<tr>\n<td>Cyanuric Acid Method<\/td>\n<td><\/td>\n<td>Adaptation of the turbidimetric method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>FLUORIDE<\/td>\n<td><\/td>\n<td>Reagents: HR &#8211; HI-93739-01 (100 tests); HI-93739-03 (300 tests)<br \/>\nLR &#8211; HI-93729-01 (100 tests); HI-93729-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Fluoride Range<\/td>\n<td><\/td>\n<td>Low Range: 0.00 to 2.00 mg\/L (as F-) High range: 0.0 to 20.0 mg\/L (as F-)<\/td>\n<\/tr>\n<tr>\n<td>Fluoride Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Fluoride Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.03 mg\/L \u00b13% of reading High Range: \u00b10.5 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Fluoride Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>HARDNESS, CALCIUM<\/td>\n<td><\/td>\n<td>Reagents: HI-93720-01 (100 tests); HI-93720-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Calcium Range<\/td>\n<td><\/td>\n<td>0.00 to 2.70 mg\/L (as CaCO3)<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Calcium Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Calcium Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.11 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Calcium Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>HARDNESS, MAGNESIUM<\/td>\n<td><\/td>\n<td>Reagents: HI-93719-01 (100 tests); HI-93719-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Magnesium Range<\/td>\n<td><\/td>\n<td>0.00 to 2.00 mg\/L (as CaCO3)<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Magnesium Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Magnesium Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.11 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Magnesium Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>HARDNESS, TOTAL<\/td>\n<td><\/td>\n<td>Reagents: HR &#8211; HI-93735-02 (100 tests); MR &#8211; HI-93735-01 (100 tests); LR &#8211; HI-93735-00 (100 tests); HR MR &amp;LR &#8211; HI-93735-0 (100 x 3 tests)<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Total Range<\/td>\n<td><\/td>\n<td>Low Range: 0 to 250 mg\/L (as CaCO3) Medium Range: 200 to 500 mg\/L (as CaCO3) High Range: 400 to 750 mg\/L (as CaCO3)<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Total Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Total Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b15 mg\/L \u00b14% of reading Medium Range: \u00b17 mg\/L \u00b13% of reading High Range: \u00b110 mg\/L \u00b12% of reading<\/td>\n<\/tr>\n<tr>\n<td>Hardness, Total Method<\/td>\n<td><\/td>\n<td>Adaptation of the EPA recommended method 130.1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>HYDRAZINE<\/td>\n<td><\/td>\n<td>Reagents: HI-93704-01 (100 tests); HI-93704-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Hydrazine Range<\/td>\n<td><\/td>\n<td>0 to 400 \u03bcg\/L (as N2H4)<\/td>\n<\/tr>\n<tr>\n<td>Hydrazine Resolution<\/td>\n<td><\/td>\n<td>1 \u03bcg\/L<\/td>\n<\/tr>\n<tr>\n<td>Hydrazine Accuracy<\/td>\n<td><\/td>\n<td>\u00b14% of full scale reading<\/td>\n<\/tr>\n<tr>\n<td>Hydrazine Method<\/td>\n<td><\/td>\n<td>Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>IODINE<\/td>\n<td><\/td>\n<td>Reagents: HI-93718-01 (100 tests); HI-93718-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Iodine Range<\/td>\n<td><\/td>\n<td>0.0 to 12.5 mg\/L (as I2)<\/td>\n<\/tr>\n<tr>\n<td>Iodine Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Iodine Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.1 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Iodine Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>IRON<\/td>\n<td><\/td>\n<td>Reagents: HR &#8211; HI-93721-01 (100 tests); HI-93721-03 (300 tests)<br \/>\nLR &#8211; HI-93746-01 (50 tests); HI-93746-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Iron Range<\/td>\n<td><\/td>\n<td>Low Range: 0.000 to 1.600 mg\/L (as Fe) High Range: 0.00 to 5.00 mg\/L (as Fe)<\/td>\n<\/tr>\n<tr>\n<td>Iron Resolution<\/td>\n<td><\/td>\n<td>0.001 mg\/L; 0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Iron Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.01 mg\/L \u00b18% of reading High Range: \u00b10.04 mg\/L \u00b12% of reading<\/td>\n<\/tr>\n<tr>\n<td>Iron Method<\/td>\n<td><\/td>\n<td>Low Range: Adaptation of the TPTZ Method High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>MAGNESIUM<\/td>\n<td><\/td>\n<td>Reagents: HI-937520-01 (50 tests); HI-937520-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Magnesium Range<\/td>\n<td><\/td>\n<td>0 to 150 mg\/L (as Mg2+)<\/td>\n<\/tr>\n<tr>\n<td>Magnesium Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Magnesium Accuracy<\/td>\n<td><\/td>\n<td>\u00b15 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Magnesium Method<\/td>\n<td><\/td>\n<td>Adaptation of the Calmagite method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>MANGANESE<\/td>\n<td><\/td>\n<td>Reagents: HR &#8211; HI-93709-01 (100 tests); HI-93709-03 (300 tests)<br \/>\nLR &#8211; HI-93748-01 (50 tests); HI-93748-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Manganese Range<\/td>\n<td><\/td>\n<td>Low Range: 0 to 300 \u00b5g\/L (as Mn) High range: 0.0 to 20.0 mg\/L (as Mn)<\/td>\n<\/tr>\n<tr>\n<td>Manganese Resolution<\/td>\n<td><\/td>\n<td>1 \u00b5g\/L; 0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Manganese Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.02 mg\/L \u00b13% of reading High Range: \u00b10.3 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Manganese Method<\/td>\n<td><\/td>\n<td>Low Range: Adaptation of the PAN Method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>MOLYBDENUM<\/td>\n<td><\/td>\n<td>Reagents: HI-93730-01 (100 tests); HI-93730-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Molybdenum Range<\/td>\n<td><\/td>\n<td>0.0 to 40.0 mg\/L (as Mo6+)<\/td>\n<\/tr>\n<tr>\n<td>Molybdenum Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Molybdenum Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.3 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Molybdenum Method<\/td>\n<td><\/td>\n<td>Adaptation of the mercaptoacetic acid method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>NICKEL<\/td>\n<td><\/td>\n<td>Reagents: HR &#8211; HI-93726-01 (100 tests); HI-93726-03 (300 tests)<br \/>\nLR &#8211; HI-93740-01 (50 tests); HI-93740-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Nickel Range<\/td>\n<td><\/td>\n<td>Low Range: 0.000 to 1.000 mg\/L (as Ni) High Range: 0.00 to 7.00 g\/L (as Ni)<\/td>\n<\/tr>\n<tr>\n<td>Nickel Resolution<\/td>\n<td><\/td>\n<td>0.001 mg\/L; 0.01 g\/L<\/td>\n<\/tr>\n<tr>\n<td>Nickel Accuracy<\/td>\n<td><\/td>\n<td>Low range: \u00b10.010 mg\/L \u00b17% of reading High Range: \u00b10.07 g\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Nickel Method<\/td>\n<td><\/td>\n<td>Low Range: Adaptation of the PAN method High Range: Adaptation of the photometric method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>NITRATE<\/td>\n<td><\/td>\n<td>Reagents: HI-93728-01 (100 tests); HI-93728-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Range<\/td>\n<td><\/td>\n<td>0.0 to 30.0 mg\/L (as NO3&#8211; N)<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.5 mg\/L \u00b110% of reading<\/td>\n<\/tr>\n<tr>\n<td>Nitrate Method<\/td>\n<td><\/td>\n<td>Adaptation of the cadmium reduction method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>NITRITE<\/td>\n<td><\/td>\n<td>Reagents: HR &#8211; HI-93708-01 (100 tests); HI-93708-03 (300 tests)<br \/>\nLR &#8211; HI-93707-01 (100 tests); HI-93707-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Range<\/td>\n<td><\/td>\n<td>Freshwater Low Range: 0 to 600 \u03bcg\/L (as NO2&#8211;N) High Range: 0 to 150 mg\/L (as NO2-) Seawater Ultra Low Range: 0 to 200 \u03bcg\/L (as NO2&#8211;N)<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Resolution<\/td>\n<td><\/td>\n<td>Freshwater: 1 \u03bcg\/L; 1 mg\/L Seawater: 1 \u03bcg\/L<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Accuracy<\/td>\n<td><\/td>\n<td>Freshwater Low Range: \u00b120 \u03bcg\/L \u00b14% of reading High Range: \u00b14 mg\/L \u00b14% of reading Seawater \u00b110 \u03bcg\/L \u00b14% of reading<\/td>\n<\/tr>\n<tr>\n<td>Nitrite Method<\/td>\n<td><\/td>\n<td>Adaptation of the EPA Diazotization method 354.1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>OXYGEN, DISSOLVED<\/td>\n<td><\/td>\n<td>Reagents: HI-93732-01 (100 tests); HI-93732-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Range<\/td>\n<td><\/td>\n<td>0.0 to 10.0 mg\/L (as O2)<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.4 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Dissolved Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>OXYGEN, SCAVENGER<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Scavenger Range<\/td>\n<td><\/td>\n<td>0 to 1000 \u03bcg\/L (as DEHA) 0.00 to 1.50 mg\/L (as Carbohydrazide) 0.00 to 2.50 mg\/L (as Hydroquinone) 0.00 to 4.50 mg\/L (as ISO-ascorbic acid)<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Scavenger Resolution<\/td>\n<td><\/td>\n<td>1 \u03bcg\/L (DEHA); 0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Scavenger Accuracy<\/td>\n<td><\/td>\n<td>\u00b15 \u03bcg\/L \u00b15% of reading (DEHA)<\/td>\n<\/tr>\n<tr>\n<td>Oxygen, Scavenger Method<\/td>\n<td><\/td>\n<td>Adaptation of the iron reduction method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>OZONE<\/td>\n<td><\/td>\n<td>Reagents: HI-93757-01 (100 tests); HI-93757-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Ozone Range<\/td>\n<td><\/td>\n<td>0.00 to 2.00 mg\/L (as O3)<\/td>\n<\/tr>\n<tr>\n<td>Ozone Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Ozone Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.02 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Ozone Method<\/td>\n<td><\/td>\n<td>Colorimetric DPD Method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>pH<\/td>\n<td><\/td>\n<td>Reagents: HI-93710-01 (100 tests); HI-93710-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>pH Range<\/td>\n<td><\/td>\n<td>Photometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Resolution<\/td>\n<td><\/td>\n<td>Photometer: 0.1 pH pH electrode: 0.1 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Accuracy<\/td>\n<td><\/td>\n<td>Photometer: \u00b10.1 pH pH electrode: \u00b10.01 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Calibration<\/td>\n<td><\/td>\n<td>Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)<\/td>\n<\/tr>\n<tr>\n<td>pH Temperature Compensation<\/td>\n<td><\/td>\n<td>Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used<\/td>\n<\/tr>\n<tr>\n<td>pH CAL Check (electrode diagnostics)<\/td>\n<td><\/td>\n<td>clean electrode and check buffer\/check probe displayed during calibration<\/td>\n<\/tr>\n<tr>\n<td>pH Method<\/td>\n<td><\/td>\n<td>Photometer: phenol red<\/td>\n<\/tr>\n<tr>\n<td>pH-mV Range<\/td>\n<td><\/td>\n<td>\u00b11000 mV<\/td>\n<\/tr>\n<tr>\n<td>pH-mV Resolution<\/td>\n<td><\/td>\n<td>0.1 mV<\/td>\n<\/tr>\n<tr>\n<td>pH-mV Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.2 mV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>PHOSPHATE<\/td>\n<td><\/td>\n<td>Reagents: HR &#8211; HI-93717-01 (100 tests); HI-93717-03 (300 tests)<br \/>\nLR &#8211; HI-93713-01 (100 tests); HI-93713-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Range<\/td>\n<td><\/td>\n<td>Freshwater Low Range: 0.00 to 2.50 mg\/L (as PO43-) High range: 0.0 to 30.0 mg\/L (as PO43-) Seawater Ultra Low Range: 0 to 200 \u03bcg\/L (as P)<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Resolution<\/td>\n<td><\/td>\n<td>Freshwater: 0.01 mg\/L; 0.1 mg\/L Seawater: 1 \u03bcg\/L<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Accuracy<\/td>\n<td><\/td>\n<td>Freshwater Low Range: \u00b10.04 mg\/L \u00b14% of reading High Range: \u00b11 mg\/L \u00b14% of reading Seawater Ultra Low Range: \u00b15 \u03bcg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Phosphate Method<\/td>\n<td><\/td>\n<td>Freshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>POTASSIUM<\/td>\n<td><\/td>\n<td>Reagents: HI-93750-01 (100 tests); HI-93750-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Potassium Range<\/td>\n<td><\/td>\n<td>0.0 to 20.0 mg\/L (as K)<\/td>\n<\/tr>\n<tr>\n<td>Potassium Resolution<\/td>\n<td><\/td>\n<td>0.1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Potassium Accuracy<\/td>\n<td><\/td>\n<td>\u00b13.0 mg\/L \u00b17% of reading<\/td>\n<\/tr>\n<tr>\n<td>Potassium Method<\/td>\n<td><\/td>\n<td>Adaptation of the Turbidimetric Tetraphenylborate method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>SILICA<\/td>\n<td><\/td>\n<td>Reagents: HR &#8211; HI-96770-01 (100 tests); HI-96770-03 (300 tests)<br \/>\nLR &#8211; HI-93705-01 (100 tests); HI-93705-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Silica Range<\/td>\n<td><\/td>\n<td>Low Range: 0.00 to 2.00 mg\/L (as SiO2) High Range: 0 to 200 mg\/L (as SiO2)<\/td>\n<\/tr>\n<tr>\n<td>Silica Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L; 1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Silica Accuracy<\/td>\n<td><\/td>\n<td>Low Range: \u00b10.03 mg\/L \u00b13% of reading High Range: \u00b11 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Silica Method<\/td>\n<td><\/td>\n<td>Low Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method High Range: Adaptation of the USEPA Method 370.1 and Standard Method 4500-SiO2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>SILVER<\/td>\n<td><\/td>\n<td>Reagents: HI-93737-01 (50 tests); HI-93737-03 (150 tests)<\/td>\n<\/tr>\n<tr>\n<td>Silver Range<\/td>\n<td><\/td>\n<td>0.000 to 1.000 mg\/L (as Ag)<\/td>\n<\/tr>\n<tr>\n<td>Silver Resolution<\/td>\n<td><\/td>\n<td>0.001 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Silver Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.020 mg\/L \u00b15% of reading<\/td>\n<\/tr>\n<tr>\n<td>Silver Method<\/td>\n<td><\/td>\n<td>Adaptation of the PAN method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>SULPHATE<\/td>\n<td><\/td>\n<td>Reagents: HI-93751-01 (100 tests); HI-93751-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Sulphate Range<\/td>\n<td><\/td>\n<td>0 to 150 mg\/L (as SO42-)<\/td>\n<\/tr>\n<tr>\n<td>Sulphate Resolution<\/td>\n<td><\/td>\n<td>1 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Sulphate Accuracy<\/td>\n<td><\/td>\n<td>\u00b15 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Sulphate Method<\/td>\n<td><\/td>\n<td>Turbidimetric &#8211; Sulphate is precipitated with barium chloride crystals<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>ZINC<\/td>\n<td><\/td>\n<td>Reagents: HI-93731-01 (100 tests); HI-93731-03 (300 tests)<\/td>\n<\/tr>\n<tr>\n<td>Zinc Range<\/td>\n<td><\/td>\n<td>0.00 to 3.00 mg\/L (as Zn)<\/td>\n<\/tr>\n<tr>\n<td>Zinc Resolution<\/td>\n<td><\/td>\n<td>0.01 mg\/L<\/td>\n<\/tr>\n<tr>\n<td>Zinc Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.03 mg\/L \u00b13% of reading<\/td>\n<\/tr>\n<tr>\n<td>Zinc Method<\/td>\n<td><\/td>\n<td>Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/article>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>HI83300 Multiparameter Photometer<\/p>\n","protected":false},"featured_media":4373,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4372"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4372"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4373"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4372"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}