{"id":4379,"date":"2020-12-01T12:05:48","date_gmt":"2020-12-01T13:05:48","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4379"},"modified":"2021-04-27T14:24:01","modified_gmt":"2021-04-27T14:24:01","slug":"hi83314-multiparameter-with-cod-photometer","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi83314-multiparameter-with-cod-photometer\/","title":{"rendered":"HI83314 Multiparameter with COD photometer"},"content":{"rendered":"<h2>HI83314 Multiparameter with COD photometer<\/h2>\n<div id=\"attachment_4380\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4380\" loading=\"lazy\" class=\"size-full wp-image-4380\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83314-300x300-1.jpg\" alt=\"HI83314 Multiparameter with COD photometer\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83314-300x300-1.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83314-300x300-1-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83314-300x300-1-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83314-300x300-1-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI83314-300x300-1-100x100.jpg 100w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-4380\" class=\"wp-caption-text\">HI83314 Multiparameter with COD photometer<\/p><\/div>\n<p>The HI83314\u00a0 is benchtop COD meter and multiparameter photometer. HI83314\u00a0 measures chemical oxygen demand and specific ions\u00a0 .<\/p>\n<p>the size of HI83314 is small and its design is ergonomic and suitable choice for most of laboratories.<\/p>\n<p>HI83314 offers fifteen different measurement methods to users..<\/p>\n<p>some other featurs such as using USB to connect to coputer , Graphic display to shows chemical forms is HI83314 options.<\/p>\n<h3>HI-83314-02 Multi-parameter Wastewater &amp; Water Photometer with COD and pH meter<\/h3>\n<div class=\"product-view__product-essential__product-shop__ask-question\"><a class=\"askquestion\" href=\"https:\/\/www.hannainstruments.co.uk\/hi-83314-02-multi-parameter-wastewater-water-photometer-with-cod-and-ph-meter.html?___SID=U#askquestion\"><i class=\"fa fa-question-circle\" aria-hidden=\"true\"><\/i>\u00a0ASK A QUESTION<\/a><\/div>\n<div class=\"product-view__product-essential__product-shop__table\">\n<div class=\"table-row\">\n<div class=\"title\"><i class=\"fa fa-info-circle\" aria-hidden=\"true\"><\/i>\u00a010 key water quality parameters<\/div>\n<\/div>\n<div class=\"table-row\">\n<div class=\"title\"><i class=\"fa fa-info-circle\" aria-hidden=\"true\"><\/i>\u00a0Advanced optical system<\/div>\n<div>HI83314 measure COD by photometric methode and pH. In fact this device is multi-parameter photometr for measuring key water parameters.<\/div>\n<div>HI83314 mostly is proper meter in water and wast water industry.<\/div>\n<div>\n<div id=\"attachment_4381\" style=\"width: 207px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4381\" loading=\"lazy\" class=\"size-full wp-image-4381\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/83314-1.jpg\" alt=\"HI83314\" width=\"197\" height=\"255\" \/><p id=\"caption-attachment-4381\" class=\"wp-caption-text\">HI83314<\/p><\/div>\n<\/div>\n<div>\n<section>\n<article>\n<div class=\"section-row\">\n<div id=\"extended-description-tabs\" class=\"extended-description\">\n<div class=\"row\">\n<div id=\"description\" class=\"section-row section 1\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<p>&nbsp;<\/p>\n<h3>below is some of Key features of HI83314:<\/h3>\n<ul>\n<li>Backlit 128 x 64 Pixel Graphic Liquid Crystal Display<\/li>\n<li>Built-in Reaction Timer for Photometric Measurements<\/li>\n<li>Absorbance mode &#8211; concentration versus absorbance<\/li>\n<li>Units of Measurement plus chemical form displayed<\/li>\n<li>Result conversion at the touch of a button<\/li>\n<li>Cuvette cover<\/li>\n<li>pH and temperature measurement with a single probe<\/li>\n<li>Good Laboratory Practice (GLP) &#8211; track calibration information including date, time, buffers used, offset and slope for traceability<\/li>\n<li>pH CAL Check alerts user to potential problems during the calibration process<\/li>\n<li>Data Logging &#8211; Up to 1000 photometric and pH readings can be stored.<\/li>\n<li>Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.<\/li>\n<li>Battery Status Indicator<\/li>\n<li>Error Messages<\/li>\n<li><\/li>\n<li><strong>list of HI83314 charactristics :<\/strong><\/li>\n<li>High Efficiency LED Light Source<\/li>\n<li>High Quality Narrow Band Interference Filters<\/li>\n<li>Reference Detector for a Stable Light Source<\/li>\n<li>Large Cuvette Size<\/li>\n<li>Focusing Lens for Greater Light Yield<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>To know <strong>HI83314 <a href=\"http:\/\/www.hannainst.com\">HANNA<\/a> price<\/strong> or <strong>buy HI83314 Multiparameter with COD<\/strong> <strong>photometer<\/strong> , please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/section>\n<div id=\"specifications\" class=\"specification col-xs-12\">\n<article>\n<h2>Specifications<\/h2>\n<section>\n<h3>Specifications list<\/h3>\n<div class=\"table\">\n<div class=\"section-row section spec\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<h3>Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<td>Input Channels<\/td>\n<td><\/td>\n<td>1 pH electrode input and 5 photometer wavelengths<\/td>\n<\/tr>\n<tr>\n<td>pH Electrode<\/td>\n<td><\/td>\n<td>Digital pH electrode (not included)<\/td>\n<\/tr>\n<tr>\n<td>Logging type<\/td>\n<td><\/td>\n<td>Log on demand with user name and sample ID optional input<\/td>\n<\/tr>\n<tr>\n<td>Logging Memory<\/td>\n<td><\/td>\n<td>1000 readings<\/td>\n<\/tr>\n<tr>\n<td>Connectivity<\/td>\n<td><\/td>\n<td>USB-A host for flash drive; micro-USB-B for power and computer connectivity<\/td>\n<\/tr>\n<tr>\n<td>GLP<\/td>\n<td><\/td>\n<td>Calibration data for connected pH electrode<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td><\/td>\n<td>128 x 64 pixel LCD with backlight<\/td>\n<\/tr>\n<tr>\n<td>Battery Type\/Life<\/td>\n<td><\/td>\n<td>3.7 VDC Li-polymer rechargeable battery\/ &gt;500 photometric measurements or 50 hours of continuous pH measurement<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td><\/td>\n<td>5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)<\/td>\n<\/tr>\n<tr>\n<td>Environment<\/td>\n<td><\/td>\n<td>0 to 50.0\u00b0C (32 to 122.0\u00b0F; 0 to 95% RH, non-condensing<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td><\/td>\n<td>206 x 177 x 97mm (8.1 x 7.0 x 3.8&#8243;)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td><\/td>\n<td>1.0 kg (2.2lbs)<\/td>\n<\/tr>\n<tr>\n<td>Photometer\/Colorimeter Light Source<\/td>\n<td><\/td>\n<td>5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters<\/td>\n<\/tr>\n<tr>\n<td>Photometer\/Colorimeter Light Detector<\/td>\n<td><\/td>\n<td>Silicon Photodetector<\/td>\n<\/tr>\n<tr>\n<td>Bandpass filter Bandwidth<\/td>\n<td><\/td>\n<td>8nm<\/td>\n<\/tr>\n<tr>\n<td>Bandpass filter wavelength accuracy<\/td>\n<td><\/td>\n<td>+-1nm<\/td>\n<\/tr>\n<tr>\n<td>Cuvette Type<\/td>\n<td><\/td>\n<td>Round, 24.6mm<\/td>\n<\/tr>\n<tr>\n<td>Number of Methods<\/td>\n<td><\/td>\n<td>128 Max<\/td>\n<\/tr>\n<tr>\n<td>Ordering Information<\/td>\n<td><\/td>\n<td>HI-83314 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/article>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>HI83314 Multiparameter with COD photometer<\/strong><\/p>\n<p>One meter can be used for both photometric and pH measurements. HI-83314 is a compact, multi-parameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. Ten key water and wastewater quality parameters with 20 different methods.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":4380,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4379"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4379"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4380"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4379"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}