{"id":4407,"date":"2020-12-05T07:25:58","date_gmt":"2020-12-05T08:25:58","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4407"},"modified":"2024-03-17T04:31:55","modified_gmt":"2024-03-17T05:31:55","slug":"hi932c2-automatic-titrator","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi932c2-automatic-titrator\/","title":{"rendered":"HI932C2 Automatic Titrator"},"content":{"rendered":"<h2>HI932C2 Automatic Titrator<\/h2>\n<div id=\"attachment_4408\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4408\" loading=\"lazy\" class=\"size-medium wp-image-4408\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI932-300x300.jpg\" alt=\"HI932-C2 Automatic Titrator\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI932-300x300.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI932-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI932-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI932-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI932-100x100.jpg 100w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI932.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-4408\" class=\"wp-caption-text\">HI932-C2 Automatic Titrator<\/p><\/div>\n<h3>HI932C2 Automatic Titrator Potentiometric Titration Systems (pH\/mV\/ISE)<\/h3>\n<p>Hanna Instruments HI932 Automatic Titrator is the perfect answer to your specific titration needs. This device is fully adjustable with accurate results and is used for various titrations including acid and base, ORP, selective ions and photometry.<\/p>\n<p>All you need to start using HI932 is a suitable electrode and titrant.<\/p>\n<p>It is small and compact so that it does not take up much space in the laboratory.<\/p>\n<p>It has a very accurate 1 to 40,000 injection pump to help you get very accurate results by getting an accurate end point.<\/p>\n<p>The HI932 automatic titrator can be ordered with one or two analog boards for successive titration.<\/p>\n<p>The HI932 automatic titrator has the ability to connect to the HI921 autosampler and it is possible to automatically test 18 samples.<\/p>\n<p>The HI-932 automatic titrator is designed to perform a wide variety of potentiometric titrations with high accuracy and flexibility, allowing the user to obtain both accurate results and high-speed analysis.<\/p>\n<p>The titrator can perform fixed endpoint or equivalence point titrations and direct measurements by measuring the pH\/mV and temperature of the sample.<\/p>\n<p>Reports and materials can be transferred to a PC via a USB interface, saved to a USB storage device or printed directly from the titrator. An external keyboard can also be attached for added convenience.<\/p>\n<p>The HI-921 &amp; HI-922 Autosamplers can be connected for sample automation.<\/p>\n<section>\n<article>\n<div class=\"section-row\">\n<div id=\"extended-description-tabs\" class=\"extended-description\">\n<div class=\"row\">\n<div class=\"section-row section two\">\n<div class=\"section-text col-xs-12 col-sm-6 add-p-r\">\n<h3>Dynamic titrant dosing<\/h3>\n<p>The dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.<\/p>\n<h3>Equivalence endpoint detection<\/h3>\n<p>Equivalence endpoint detection is critical in applications where fixed endpoints are not specified in standard methods. This endpoint indicates where the mV response from the titration is greatest with respect to the volume of titrant dosed.<\/p>\n<h3>Signal stability timing<\/h3>\n<p>The signal stability feature monitors when the mV response of the titration reaction stabilises before providing the next titrant dose. This ensures reliable measurement values throughout the length of a titration.<\/p>\n<h3>Multiple equivalence point detection<\/h3>\n<p>HI932C2 Automatic Titrator can detect multiple equivalence points during one titration as specified and required in certain standard methods and applications.<\/p>\n<\/div>\n<div class=\"section-text col-xs-12 col-sm-6 add-p-l\">\n<h3>Method sequencing<\/h3>\n<p>HI932C2 Automatic Titrator offers users the option of linking two methods. This allows for two analyses to be run on the same sample including direct measurements, single endpoint titrations, multiple equivalence point titrations, and back titrations.<\/p>\n<h3>Multiple titration types<\/h3>\n<p>Paired with the right electrode from our sensor line, our potentiometric titrators can perform acid\/base, redox (ORP), complexometric, precipitation, non-aqueous, argentometric, and ion selective titrations, as well as back titrations and titre determinations.<\/p>\n<h3>Direct measurement functionality<\/h3>\n<p>HI932C2 Automatic Titrator performs as a high accuracy pH, ORP, and ion selective meter that can link, log, and report direct measurements. Users can easily track and manage data without the hassle of manual record keeping.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section four\">\n<div class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\">\n<h3><span style=\"color: blue;\">Burettes and dosing system<\/span><\/h3>\n<h3>Exchangeable burette system<\/h3>\n<p>With Hanna\u2019s Clip-Lock\u2122 burette feature, it only takes a few seconds to exchange titrants and reagents preventing cross-contamination and saving time.<\/p>\n<h3>Multiple burette sizes<\/h3>\n<p>HI932C2 Automatic Titrator comes supplied with a 25mL burette but may be equipped with a 5mL, 10mL or 50mL burette. Each burette is constructed with a ground glass syringe and chemically resistant PTFE plunger.<\/p>\n<h3>Precision dosing pump<\/h3>\n<p>Our unmatched 40,000 step piston driven pump is capable of dosing extremely small and highly accurate volumes of titrant or reagent.<\/p>\n<h3>Automatic reagent addition<\/h3>\n<p>A peristaltic pump or a second burette may be programmed to volumetrically dispense reagent prior to titration or direct measurement. This helps achieve consistent and accurate results and prevents operator errors such as incorrect volumes or forgetting reagent addition.<\/p>\n<\/div>\n<div class=\"section-image col-xs-12 col-sm-5 rem-p-r\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/932-Titrator_Right-Angle-Raised-2_detail_1.jpg\" alt=\"\" \/><\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section five\">\n<div class=\"section-image col-xs-12 col-sm-5 rem-p-l\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/932-931-Titrator_Electrode-Holder-b-2_detail_2.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-text hidden-xs col-sm-7 add-p-l rem-p-r\">\n<h3>Redesigned electrode holder<\/h3>\n<ul>\n<li>Spring-loaded actuator allows you to quickly raise or lower the stirrer\/electrodes with the push of a button<\/li>\n<li>Space-saving geometry allows for sample sizes less than 50mL<\/li>\n<li>Support rods mount directly to the titrator \u2013 no need for special mounting hardware<\/li>\n<\/ul>\n<h3>Peristaltic pumps<\/h3>\n<ul>\n<li>Add reagents to your samples automatically before every titration using integrated peristaltic pumps<\/li>\n<\/ul>\n<h3>Redesigned burette well<\/h3>\n<ul>\n<li>The burette well is sealed on the bottom to catch drips and spills<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section ten\">\n<div class=\"col-xs-12 col-sm-4 rem-pad-mobile rem-p-l\">\n<div class=\"section-image col-xs-6\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/titration-fruit_3.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-image col-xs-6\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/titration-milk_3.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-text col-xs-12\">\n<h3><span style=\"color: blue;\">Methods of analysis<\/span><\/h3>\n<h3>Customizable methods<\/h3>\n<p>These titrators can store up to 100 user-defined or standard titration and direct measurement methods. Each method may be modified and optimized for performance based on application and user requirements.<\/p>\n<h3>Titration method support<\/h3>\n<p>Onsite installation, training, and customisation is available from one of our product specialists. Hanna offers continued support for any questions you might have along the way.<\/p>\n<h3>Market specific methods packs<\/h3>\n<p>Hanna offers titration method packages for various markets including food, beverage, dairy, wine, and more.<\/p>\n<\/div>\n<\/div>\n<div class=\"col-xs-12 col-sm-4 rem-pad-mobile\">\n<div class=\"section-image col-xs-6\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/titration-wine_4.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-text col-xs-12 text-left\">\n<h3>Data Storage<\/h3>\n<p>Up to 100 titration and pH\/mV\/ISE reports. Transfer data via USB<\/p>\n<p>.<span style=\"font-size: 20px; font-weight: 600;\">Flexible GLP management <\/span>All necessary GLP (Good Laboratory Practice) information can be recorded with each sample.<\/p>\n<\/div>\n<\/div>\n<div class=\"col-xs-12 col-sm-4 rem-pad-mobile rem-p-r\">\n<div class=\"section-image col-xs-6\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/932-Titrator_back-Straight_detail_4.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-image col-xs-6\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/921default_2.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-text col-xs-12\">\n<h3><span style=\"color: blue;\">Connectivity and functionality<\/span><\/h3>\n<h3>Multifunctional<\/h3>\n<p>The titrators also function as a titrator, pH meter, mV\/ORP meter, and ISE meter. Valuable laboratory bench space is saved, and multiple analyses can be performed on one sample.<\/p>\n<h3>Multiple Connections<\/h3>\n<p>HI932C2 Automatic Titrator offers support for two analog boards, allowing up to two electrodes, two burettes, and two stirrers to be connected to one unit simultaneously.<\/p>\n<h3>Autosampler connectivity<\/h3>\n<p>HI932C2 Automatic Titrator works seamlessly with the HI-922 autosampler featuring 16 or 18 sample tray options, automatic tray identification, and automatic beaker detection. Up to three peristaltic pumps for reagent addition and removal can be connected and real-time analysis and sequencing progress is visible on the HI-932 display as well as indicated by the LED lights of the autosampler.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section eleven\">\n<div class=\"col-xs-12 col-sm-6 rem-pad-mobile rem-p-l\">\n<div class=\"section-image col-xs-4 col-sm-4\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/932_931Titration_view_mod_method_screen_1_1.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-image col-xs-4 col-sm-4\"><\/div>\n<div class=\"section-image col-xs-4 col-sm-4\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/932_931Titration_setup_3_1.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-text col-xs-12\">\n<h3><span style=\"color: blue;\">Interface and display<\/span><\/h3>\n<h3>Interactive colour display<\/h3>\n<p>A large, colour LCD screen clearly shows the chosen titration method along with results, units, titration volume, temperature, and mV or pH values.<\/p>\n<h3>Detailed titration graphs<\/h3>\n<p>A real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.<\/p>\n<\/div>\n<\/div>\n<div class=\"col-xs-12 col-sm-6 rem-pad-mobile rem-p-r\">\n<div class=\"section-image col-xs-4 col-sm-4\"><\/div>\n<div class=\"section-image col-xs-4 col-sm-4\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/932_931Titration_graphs_2_1.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-image col-xs-4 col-sm-4\"><\/div>\n<div class=\"section-text col-xs-12\">\n<h3><span style=\"color: blue;\">Fully customizable titration methods<\/span><\/h3>\n<h3>Titration graphs<\/h3>\n<p>Titration graphs can be viewed on-screen or saved as images and transferred along with titration report.<\/p>\n<h3>Customizable reports<\/h3>\n<p>Data to be stored in titration reports is fully customizable.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"section-row section twelve\">\n<div class=\"col-xs-12 rem-pad-mobile rem-p-l rem-p-r\">\n<div class=\"row\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/section>\n<div id=\"specifications\" class=\"specification col-xs-12\">\n<article>\n<h2>Specifications<\/h2>\n<section>To know <strong>HI932 <a href=\"http:\/\/www.hannainst.com\">HANNA<\/a> price<\/strong> or <strong>buy HI932C2 Automatic Titrator<\/strong> , please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/p>\n<div class=\"table\">\n<div class=\"section-row section spec\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<h3>HI932C2 Automatic Titrator Specifications:<\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>pH<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Range<\/td>\n<td><\/td>\n<td>-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>0.1; 0.01; 0.001 pH<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy (@25\u00b0C)<\/td>\n<td><\/td>\n<td>\u00b10.001 pH<\/td>\n<\/tr>\n<tr>\n<td>pH Calibration<\/td>\n<td><\/td>\n<td>up to five-point calibration, eight standard buffers and five custom buffers<\/td>\n<\/tr>\n<tr>\n<td><b>mV<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Range<\/td>\n<td><\/td>\n<td>-2000.0 to 2000.0 mV<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>0.1 mV<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy (@25\u00b0C)<\/td>\n<td><\/td>\n<td>\u00b10.1 mV<\/td>\n<\/tr>\n<tr>\n<td>\u2003mV Calibration<\/td>\n<td><\/td>\n<td>single point offset<\/td>\n<\/tr>\n<tr>\n<td><b>ISE<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Range<\/td>\n<td><\/td>\n<td>1\u202210<sup>-6<\/sup>\u00a0to 9.99\u202210<sup>10<\/sup><\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>1; 0.1; 0.01<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy (@25\u00b0C)<\/td>\n<td><\/td>\n<td>\u00b10.5% monovalent; \u00b11% divalent<\/td>\n<\/tr>\n<tr>\n<td>\u2003ISE Calibration<\/td>\n<td><\/td>\n<td>Up to five-point calibration, seven standard solutions and five user-defined standards<\/td>\n<\/tr>\n<tr>\n<td><b>Temperature<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Range<\/td>\n<td><\/td>\n<td>-5.0 to 105.0\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>0.1\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy (@25\u00b0C)<\/td>\n<td><\/td>\n<td>\u00b10.1\u00b0C excluding probe error<\/td>\n<\/tr>\n<tr>\n<td><b>Additional Specifications<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Analog Board(s) capability<\/td>\n<td><\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>\u2003Dosing Pump Capability<\/td>\n<td><\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>\u2003Burette included<\/td>\n<td><\/td>\n<td>1 (25mL)<\/td>\n<\/tr>\n<tr>\n<td>\u2003Burette Size Capability<\/td>\n<td><\/td>\n<td>5, 10, 25 and 50 mL<\/td>\n<\/tr>\n<tr>\n<td>\u2003Burette Resolution<\/td>\n<td><\/td>\n<td>1\/40000<\/td>\n<\/tr>\n<tr>\n<td>\u2003Display Resolution<\/td>\n<td><\/td>\n<td>0.001 mL<\/td>\n<\/tr>\n<tr>\n<td>\u2003Dosing Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.1% of full burette volume<\/td>\n<\/tr>\n<tr>\n<td>\u2003Display<\/td>\n<td><\/td>\n<td>14.9cm (5.7\u201d) 320 x 240 pixel) backlit colour LCD<\/td>\n<\/tr>\n<tr>\n<td>\u2003GLP Conformity<\/td>\n<td><\/td>\n<td>Instrumentation data storage and printing capabilities<\/td>\n<\/tr>\n<tr>\n<td>\u2003Linked Methods<\/td>\n<td><\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>\u2003Back Titrations<\/td>\n<td><\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>\u2003HI-921 &amp; HI-922 autosampler compatible<\/td>\n<td><\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>\u2003Power<\/td>\n<td><\/td>\n<td>100-240 VAC<\/td>\n<\/tr>\n<tr>\n<td><b>Ordering information<\/b><\/td>\n<td><\/td>\n<td>HI-932C2-02 includes titrator with two analog boards*<br \/>\nAll models also include: overhead propeller stirrer with stand, 25ml glass burette, dosing pump, temperature sensor, USB cable, USB Flash drive and PC Software.<\/td>\n<\/tr>\n<tr>\n<td><b>Additional Extras<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003HI-930101<\/td>\n<td><\/td>\n<td>Dosing pump with peristaltic pump<\/td>\n<\/tr>\n<tr>\n<td>\u2003HI-930100<\/td>\n<td><\/td>\n<td>Dosing pump<\/td>\n<\/tr>\n<tr>\n<td>\u2003HI-930150<\/td>\n<td><\/td>\n<td>50 mL burette assembly (includes syringe, aspiration, and dispensing tubes)<\/td>\n<\/tr>\n<tr>\n<td>\u2003HI-930125<\/td>\n<td><\/td>\n<td>25 mL burette assembly (includes syringe, aspiration, and dispensing tubes)<\/td>\n<\/tr>\n<tr>\n<td>\u2003HI-930110<\/td>\n<td><\/td>\n<td>10 mL burette assembly (includes syringe, aspiration, and dispensing tubes)<\/td>\n<\/tr>\n<tr>\n<td>\u2003HI-930105<\/td>\n<td><\/td>\n<td>5 mL burette assembly (includes syringe, aspiration, and dispensing tubes)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>*Each Analog board provides 1 BNC (pH, mV, ISE) input, 1 temperature input, 1 stirrer input.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/article>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h3>HI932C2 Automatic Titrator<\/h3>\n<h3>HI932C2 Automatic Titrator \u00a0(pH\/mV\/ISE)<\/h3>\n<p>The HI-932 automatic titrator is designed to perform a wide variety of potentiometric titrations with high accuracy and flexibility, allowing the user to obtain both accurate results and high-speed analysis.<\/p>\n<p>The titrator can perform fixed endpoint or equivalence point titrations and direct measurements by measuring the pH\/mV and temperature of the sample.<\/p>\n","protected":false},"featured_media":4408,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4407"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4407"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4408"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}