{"id":4415,"date":"2020-12-05T08:04:11","date_gmt":"2020-12-05T09:04:11","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4415"},"modified":"2021-04-25T15:17:10","modified_gmt":"2021-04-25T15:17:10","slug":"hi921-autosampler-for-automatic-titrator","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi921-autosampler-for-automatic-titrator\/","title":{"rendered":"HI921 Autosampler for Automatic Titrator"},"content":{"rendered":"<h2>HI921 Autosampler for Automatic Titrator<\/h2>\n<p>what is Autosampler ?<\/p>\n<p>Autosample is an automatic titration sample holder system.<\/p>\n<p>Autosampler can be use with the HI902C automatic titration .<\/p>\n<p>The HI921 Autosampler suitable for Automatic Titrator can be equipped with more than three pumps to add regent, sample surface and aspiration losses<\/p>\n<p>T<\/p>\n<div id=\"attachment_4416\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4416\" loading=\"lazy\" class=\"size-medium wp-image-4416\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-300x300.jpg\" alt=\"HI921 Autosampler for Automatic Titrator\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-300x300.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-768x768.jpg 768w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-705x705.jpg 705w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-100x100.jpg 100w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-600x600.jpg 600w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1.jpg 900w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-4416\" class=\"wp-caption-text\">HI921 Autosampler for Automatic Titrator<\/p><\/div>\n<section>\n<article>\n<div class=\"section-row\">\n<div id=\"extended-description-tabs\" class=\"extended-description\">\n<div class=\"row\">\n<div id=\"description\" class=\"section-row section 1\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<h3>Autosampler with 18 beaker tray<\/h3>\n<p>with Using of 18 beaker autosampler, device can run up to 18 samples .<\/p>\n<ul>\n<li style=\"list-style-type: none;\"><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section two\">\n<div class=\"section-text col-xs-12 col-sm-6 add-p-r\">\n<h3>the list of benefits of Autosampler:<\/h3>\n<ul>\n<li>Flexible, accurate detection of the titration endpoint with HI-902C potentiometric titrator<\/li>\n<li>Automation of up to 18 samples per tray \u2013 16 sample tray holds 150ml beakers; 18 sample tray holds 100ml beakers<\/li>\n<li>Absolute encoder in sample tray \u2013 The autosampler always knows the tray position. It never needs calibration and never needs to \u201chome\u201d<\/li>\n<li>Electrode rinse feature \u2013 up to 3 beakers per tray can be designated for electrode dip rinses; a primary, secondary and tertiary rinse.<\/li>\n<li>Automatic addition of reagents or deionized water to the sample beaker by peristaltic pump<\/li>\n<li>Control panel for manual operation of motors and pumps (included)<\/li>\n<li>Built-in magnetic stirrer or optional overhead propeller stirrer<\/li>\n<li>Barcode reader interface for easy sample tracking \u2013 USB barcode reader interface for easy sample identification<\/li>\n<li>Built-in RFID in each tray, communicating tray serial number and number of beakers it holds<\/li>\n<\/ul>\n<\/div>\n<div class=\"section-text col-xs-12 col-sm-6 add-p-l\">\n<ul>\n<li>Optical IR beam detects presence or absence of beakers in the tray \u2013 ensures the autosampler doesn\u2019t proceed with titration if a beaker is missing<\/li>\n<li>USB interface \u2013 use with barcode reader; field upgradable software<\/li>\n<li>Sample trays made of chemically-resistant materials are removable, easy to clean and dishwasher safe<\/li>\n<li>Electrode holder can accommodate 3 x 12mm electrodes, temperature sensor, 1 aspiration tube, and 5 multipurpose tubes (reagent addition, burette dosing) \u2013 Allows user to switch between methods without physically switching electrodes<\/li>\n<li>Real time progress of the sequence and results shown on the HI-902 titrator screen<\/li>\n<li>Integrated peristaltic (up to 3) pump<\/li>\n<li>Sample levelling feature \u2013 automatic levelling for fast preparation of volumetric samples<\/li>\n<li>Waste removal feature \u2013 Aspirate completed samples into a waste container<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section four\">\n<div class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\">\n<p>The Autosampler includes up to three peristaltic pumps. The pump system has a simple install process and can be connected without the need of a technician.<\/p>\n<ul>\n<li>Up to 3 peristaltic pumps can be added at any time<\/li>\n<li>User replaceable pump systems<\/li>\n<li>Peristaltic \u2013 uses high performance plastic engineering to be chemically resistant, with long service life. Resistant to temperature fluctuations; Reagent addition, sample levelling, waste removal; greater than 200 mL\/min flow.<\/li>\n<\/ul>\n<\/div>\n<div class=\"section-image col-xs-12 col-sm-5 rem-p-r\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/921_4_7.jpg\" alt=\"\" \/><\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section five\">\n<div class=\"section-image col-xs-12 col-sm-5 rem-p-l\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/921alt1_3.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-text hidden-xs col-sm-7 add-p-l rem-p-r\">\n<p><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/921_1_8.jpg\" alt=\"\" \/><\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section eleven\">\n<div class=\"col-xs-12 col-sm-6 rem-pad-mobile rem-p-l\">\n<div class=\"section-image col-xs-4 col-sm-4\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/921_2_8.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-image col-xs-4 col-sm-4\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/921_3_8.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-text col-xs-12\">\n<p>&nbsp;<\/p>\n<h3>Status indicator lights<\/h3>\n<p>&nbsp;<\/p>\n<p><strong>Green <\/strong>\u2013 Steady green \u2013 idle, ready to start; flashing green \u2013 running<\/p>\n<\/div>\n<\/div>\n<div class=\"col-xs-12 col-sm-6 rem-pad-mobile rem-p-r\">\n<div class=\"section-text col-xs-12\">\n<p><strong>Yellow\u00a0<\/strong>\u2013 Flashing yellow \u2013 paused<\/p>\n<p><strong>Red<\/strong>\u00a0\u2013 Error or emergency stopped, or initialising during power on<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"section-row section twelve\">\n<div class=\"col-xs-12 rem-pad-mobile rem-p-l rem-p-r\">\n<div class=\"row\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/section>\n<div id=\"specifications\" class=\"specification col-xs-12\">\n<article>\n<h2>Specifications<\/h2>\n<section>To know <strong>HI921 <a href=\"http:\/\/www.hannainst.com\">HANNA<\/a> price<\/strong> or <strong>buy HI921 Autosampler for Automatic<\/strong> <strong>Titrator<\/strong> , please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/p>\n<div class=\"table\">\n<div class=\"section-row section spec\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<h3>HI921 Autosampler for Automatic Titrator Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<td>Electrode Holder Slots<\/td>\n<td><\/td>\n<td>3 x 12mm electrodes<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>1 temperature sensor<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>1 aspiration tube<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>5 multi-purpose slots (titrant\/reagent tubes)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>1 overhead stirrer<\/td>\n<\/tr>\n<tr>\n<td>Temperature Sensor<\/td>\n<td><\/td>\n<td>HI-7662-A (included)<\/td>\n<\/tr>\n<tr>\n<td>Stirrers<\/td>\n<td><\/td>\n<td>Built-in magnetic stirrer<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Optional overhead propeller stirrer<\/td>\n<\/tr>\n<tr>\n<td>Peristaltic pumps<\/td>\n<td><\/td>\n<td>Up to 3 can be installed<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Installs in slots #1, 2, 3<\/td>\n<\/tr>\n<tr>\n<td>Trays<\/td>\n<td><\/td>\n<td>16 beakers x 150mL (HI-920-11660)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>18 beakers x 100mL (Hi-920-11853)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Built-in RFID, transmits the tray type and serial number to autosampler<\/td>\n<\/tr>\n<tr>\n<td>Beakers<\/td>\n<td><\/td>\n<td>ASTM Short-form glass beakers<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>HI-920-060 (150mL), fits HI-920-11660 tray &#8211; plastic beakers<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>HI-920-053 (100mL), fits HI-920-11853 tray &#8211; plastic beakers<\/td>\n<\/tr>\n<tr>\n<td>Control Panel<\/td>\n<td><\/td>\n<td>Buttons for manual operation of tray<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Manual operation of peristaltic pump(s)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>2-line backlit display with status information<\/td>\n<\/tr>\n<tr>\n<td>Barcode reader<\/td>\n<td><\/td>\n<td>Compatible with USB barcode readers. Use to add sample names<\/td>\n<\/tr>\n<tr>\n<td>Report storage<\/td>\n<td><\/td>\n<td>Up to 40 trays of samples \u2013 720 reports for 18-beaker tray<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/article>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2>HI921 Autosampler for Automatic Titrator<\/h2>\n<p>The HI921 Autosampler for Automatic Titrator is an automated titration sample handling system designed for use with the HI-902C Potentiometric Titration System. This high quality system makes the titration of multiple samples quick and easy.<\/p>\n[caption id=\"attachment_4416\" align=\"aligncenter\" width=\"300\"]<img loading=\"lazy\" class=\"size-medium wp-image-4416\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-300x300.jpg\" alt=\"HI921 Autosampler for Automatic Titrator\" width=\"300\" height=\"300\" srcset=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-300x300.jpg 300w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-80x80.jpg 80w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-768x768.jpg 768w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-36x36.jpg 36w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-180x180.jpg 180w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-705x705.jpg 705w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-100x100.jpg 100w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1-600x600.jpg 600w, https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/HI921-1.jpg 900w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> HI921 Autosampler for Automatic Titrator[\/caption]\n<section>\n<article>\n<div class=\"section-row\">\n<div id=\"extended-description-tabs\" class=\"extended-description\">\n<div class=\"row\">\n<div id=\"description\" class=\"section-row section 1\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<h3>Autosampler with 18 beaker tray<\/h3>\n<p>Using the autosampler, up to 18 samples can be run consecutively. The HI921 Autosampler for Automatic Titrator also interfaces directly with the HI902C to access titration methods. Once a method is established, the user can customize the automation sequence samples for the method. Sample names and size can be customized or auto filled in with preset values.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/section>\n","protected":false},"featured_media":4416,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4415"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4415"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4416"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4415"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}