{"id":4430,"date":"2020-12-05T09:07:51","date_gmt":"2020-12-05T10:07:51","guid":{"rendered":"https:\/\/sa-aria.com\/en\/?post_type=product&#038;p=4430"},"modified":"2021-04-25T14:55:46","modified_gmt":"2021-04-25T14:55:46","slug":"hi903-karl-fischer-volumetric","status":"publish","type":"product","link":"https:\/\/sa-aria.com\/en\/product\/hi903-karl-fischer-volumetric\/","title":{"rendered":"HI903 Karl Fischer Volumetric"},"content":{"rendered":"<h2>HI903 Karl Fischer Volumetric<\/h2>\n<div id=\"attachment_4432\" style=\"width: 229px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-4432\" loading=\"lazy\" class=\"size-full wp-image-4432\" src=\"https:\/\/sa-aria.com\/en\/wp-content\/uploads\/2020\/12\/903.jpg\" alt=\"HI903 Karl Fischer Volumetric\" width=\"219\" height=\"231\" \/><p id=\"caption-attachment-4432\" class=\"wp-caption-text\">HI903 Karl Fischer Volumetric<\/p><\/div>\n<p>THI903 Karl Fischer\u00a0 is a Karl fisher whom measure the amount of\u00a0 waters with Volumetric method . The range of measuring is between 0.01 to 100% .<\/p>\n<p>&nbsp;<\/p>\n<p><strong>The details of\u00a0 Precision titrant delivery system been listed as below:\u00a0<\/strong><\/p>\n<section>\n<article>\n<div class=\"section-row\">\n<div id=\"extended-description-tabs\" class=\"extended-description\">\n<div class=\"row\">\n<div id=\"description\" class=\"section-row section 1\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<ul>\n<li>40,000 step, piston dosing pump<\/li>\n<li>Accurate to 0.1%<\/li>\n<li>Delivers as little as 0.125 \u00b5L of titrant<\/li>\n<li>Precision ground, 5 mL glass burette with PTFE plunger, PTFE burette tubing, and polyurethane tube jacketing (thermally insulating, light blocking)<\/li>\n<li>Glass anti-diffusion dispensing tip<\/li>\n<li>Clip-Lock\u2122 exchangeable burette system enables users to exchange reagent burettes in a matter of seconds<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><b>Sealed solvent system<\/b><\/p>\n<p><b>Beaker top<\/b><\/p>\n<p><b>Anti-diffusion burette tip<\/b><\/p>\n<p><b>Built-in stirrer<\/b><\/p>\n<p><b>Rechargeable indicating desiccant<\/b><\/p>\n<p><b>PTFE bottle cap<\/b><\/p>\n<p><span style=\"font-size: 20px; font-weight: 600;\">Clip-Lock\u2122 Exchangeable Burette System<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section four\">\n<div class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\">\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<div class=\"section-image col-xs-12 col-sm-5 rem-p-r\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/903_1.jpg\" alt=\"\" \/><\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"section-row section nine\">\n<div class=\"col-xs-12 col-sm-6 rem-pad-mobile rem-p-l\">\n<div class=\"section-image col-xs-5 col-sm-3 circle-left\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/pc_roundel_175.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-text col-xs-7 col-sm-9\">\n<p>PC Interface &#8211; Download test results to a computer programmed with HANNA\u2019s Windows\u00ae compatible software directly from equipment via a USB port or a RS232 cable outlet.<\/p>\n<\/div>\n<\/div>\n<div class=\"col-xs-12 col-sm-6 rem-pad-mobile rem-p-r\">\n<div class=\"section-image col-xs-5 col-sm-3 circle-left\"><img class=\"img-responsive\" title=\"\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/clip_lock_interchangable_roundel_13.jpg\" alt=\"\" \/><\/div>\n<div class=\"section-text col-xs-7 col-sm-9\">\n<p>Clip-Lock\u2122 exchangeable burette system enables users to change burettes in seconds!<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/section>\n<div id=\"specifications\" class=\"specification col-xs-12\">\n<article>\n<h2>Specifications<\/h2>\n<section>To know <strong>HI903 <a href=\"http:\/\/www.hannainst.com\">HANNA<\/a> price<\/strong> or <strong>buy HI903 Karl Fischer Volumetric<\/strong> , please contact <a href=\"http:\/\/www.sa-aria.com\"><strong>Setare Arsh Aria<\/strong><\/a> company.<\/p>\n<div class=\"table\">\n<div class=\"section-row section spec\">\n<div class=\"section-text col-xs-12 rem-p-l rem-p-r\">\n<h3>HI903 Karl Fischer Volumetric technical\u00a0 Specifications:<\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>Range<\/b><\/td>\n<td><\/td>\n<td>&lt;100 ppm to 100%<\/td>\n<\/tr>\n<tr>\n<td><b>Resolution<\/b><\/td>\n<td><\/td>\n<td>1 ppm (0.0001%)<\/td>\n<\/tr>\n<tr>\n<td><b>Result Units<\/b><\/td>\n<td><\/td>\n<td>%, ppm, mg\/g, \u00b5g\/g, mg, \u00b5g, mg\/mL, \u00b5g\/mL, mg\/pc, \u00b5g\/pc<\/td>\n<\/tr>\n<tr>\n<td><b>Sample Type<\/b><\/td>\n<td><\/td>\n<td>liquid or solid<\/td>\n<\/tr>\n<tr>\n<td><b>Determination:<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Pre-Titration Conditioning<\/td>\n<td><\/td>\n<td>automatic<\/td>\n<\/tr>\n<tr>\n<td>\u2003Background Drift Correction<\/td>\n<td><\/td>\n<td>automatic or user selectable value<\/td>\n<\/tr>\n<tr>\n<td>\u2003Endpoint Criteria<\/td>\n<td><\/td>\n<td>fixed mV persistence, relative drift stop or absolute drift stop<\/td>\n<\/tr>\n<tr>\n<td>\u2003Dosing<\/td>\n<td><\/td>\n<td>dynamic with optional pre-dispensing rate<\/td>\n<\/tr>\n<tr>\n<td>\u2003Result Statistic<\/td>\n<td><\/td>\n<td>mean, standard deviation<\/td>\n<\/tr>\n<tr>\n<td><b>Clip Lock\u2122:<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Dosing Pump Resolution<\/td>\n<td><\/td>\n<td>1\/40000 of the burette volume (0.125 \u00b5L per dose)<\/td>\n<\/tr>\n<tr>\n<td>\u2003Dosing Pump Accuracy<\/td>\n<td><\/td>\n<td>\u00b10.1% of full burette volume<\/td>\n<\/tr>\n<tr>\n<td>\u2003Syringe<\/td>\n<td><\/td>\n<td>5 mL precision ground glass with PTFE plunger<\/td>\n<\/tr>\n<tr>\n<td>\u2003Valve<\/td>\n<td><\/td>\n<td>motor driven 3-way, PTFE liquid contact material<\/td>\n<\/tr>\n<tr>\n<td>\u2003Tubing<\/td>\n<td><\/td>\n<td>PTFE with light block and thermal jacketing<\/td>\n<\/tr>\n<tr>\n<td>\u2003Dispensing Tip<\/td>\n<td><\/td>\n<td>glass, fixed position, anti-diffusing<\/td>\n<\/tr>\n<tr>\n<td>\u2003Titration Vessel<\/td>\n<td><\/td>\n<td>conical with operation volume between 50-150 mL<\/td>\n<\/tr>\n<tr>\n<td>\u2003Solvent Handling System<\/td>\n<td><\/td>\n<td>sealed system, integrated diaphragm air pump<\/td>\n<\/tr>\n<tr>\n<td><b>Electrode:<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Type<\/td>\n<td><\/td>\n<td>dual platinum pin, polarisation electrode<\/td>\n<\/tr>\n<tr>\n<td>\u2003Connection<\/td>\n<td><\/td>\n<td>BNC<\/td>\n<\/tr>\n<tr>\n<td>\u2003Polarization Current<\/td>\n<td><\/td>\n<td>1, 2, 5, 10, 15, 20, 30 or 40 \u00b5A<\/td>\n<\/tr>\n<tr>\n<td>\u2003Voltage Range<\/td>\n<td><\/td>\n<td>2 mV to 1000 mV<\/td>\n<\/tr>\n<tr>\n<td>\u2003Voltage Resolution<\/td>\n<td><\/td>\n<td>0.1 mV<\/td>\n<\/tr>\n<tr>\n<td>\u2003Accuracy (@25\u00baC\/77\u00baF)<\/td>\n<td><\/td>\n<td>\u00b10.1%<\/td>\n<\/tr>\n<tr>\n<td><b>External Stirrer:<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003Type<\/td>\n<td><\/td>\n<td>magnetic, optically regulated, digital stirrer<\/td>\n<\/tr>\n<tr>\n<td>\u2003Speed<\/td>\n<td><\/td>\n<td>200-2000 rpm<\/td>\n<\/tr>\n<tr>\n<td>\u2003Resolution<\/td>\n<td><\/td>\n<td>100 rpm<\/td>\n<\/tr>\n<tr>\n<td><b>Peripheral Devices:<\/b><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\u2003PC<\/td>\n<td><\/td>\n<td>easily view, transfer, print or delete methods and reports via HI-900PC application<\/td>\n<\/tr>\n<tr>\n<td>\u2003USB Flash Drive<\/td>\n<td><\/td>\n<td>easily upgrade software or transfer methods and reports between devices using a USB drive<\/td>\n<\/tr>\n<tr>\n<td>\u2003Laboratory Analytical Balance<\/td>\n<td><\/td>\n<td>RS232 to connect any laboratory balance<\/td>\n<\/tr>\n<tr>\n<td>\u2003Printer<\/td>\n<td><\/td>\n<td>print directly from the HI 903 to a printer via parallel port<\/td>\n<\/tr>\n<tr>\n<td>\u2003Monitor<\/td>\n<td><\/td>\n<td>instrument status and titrations can be viewed on a larger screen using any VGA compatible external monitor<\/td>\n<\/tr>\n<tr>\n<td>\u2003Keyboard<\/td>\n<td><\/td>\n<td>alphanumeric text can be entered using an optional PS\/2 keyboard<\/td>\n<\/tr>\n<tr>\n<td><b>Graphic Display<\/b><\/td>\n<td><\/td>\n<td>5.7\u201d (320 x 240 pixel) color LCD<\/td>\n<\/tr>\n<tr>\n<td><b>Titration Methods<\/b><\/td>\n<td><\/td>\n<td>up to 100 (standard and user) methods<\/td>\n<\/tr>\n<tr>\n<td><b>Data Storage<\/b><\/td>\n<td><\/td>\n<td>up to 100 complete titration reports and drift rate reports can be stored<\/td>\n<\/tr>\n<tr>\n<td><b>GLP Conformity<\/b><\/td>\n<td><\/td>\n<td>Good Laboratory Practice and instrument data storage and printing<\/td>\n<\/tr>\n<tr>\n<td><b>Languages<\/b><\/td>\n<td><\/td>\n<td>English, Portuguese and Spanish<\/td>\n<\/tr>\n<tr>\n<td><b>Enclosure Material<\/b><\/td>\n<td><\/td>\n<td>ABS plastic and steel<\/td>\n<\/tr>\n<tr>\n<td><b>Keypad<\/b><\/td>\n<td><\/td>\n<td>polycarbonate<\/td>\n<\/tr>\n<tr>\n<td><b>Power Supply<\/b><\/td>\n<td><\/td>\n<td>\u201c-02\u201d model: 230VAC, 50\/60 Hz;<\/td>\n<\/tr>\n<tr>\n<td><b>Operating Environment<\/b><\/td>\n<td><\/td>\n<td>10 to 40\u00baC, up to 95% RH<\/td>\n<\/tr>\n<tr>\n<td><b>Storage Environment<\/b><\/td>\n<td><\/td>\n<td><small>-20 to 70\u00baC, up to 95% RH<\/small><\/td>\n<\/tr>\n<tr>\n<td><b>Dimensions<\/b><\/td>\n<td><\/td>\n<td>390 x 350 x 380 mm (15.3 x 13.8 x 14.9\u201d)<\/td>\n<\/tr>\n<tr>\n<td><b>Weight<\/b><\/td>\n<td><\/td>\n<td>approximately 10 kg (22 lbs.)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Order Information:<\/p>\n<p>HI903 Karl Fischer Volumetric (230V) are supplied with dual platinum pin electrode, dosing pump, 5 mL burette assembly with tubing, air pump assembly with tubing, beaker and bottle top assemblies and all fittings, desiccant cartridges (4) with indicating desiccant, stir bar, waste bottle, calibration key, USB cable, power cable, HI 900PC application, USB flash drive, quality certificate, ISO 8655 burette compliance report and instruction manual binder.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/article>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2>HI903 Karl Fischer Volumetric<\/h2>\n<p>THI903 Karl Fischer Volumetric is a reliable device for testing the exact amount of water in solutions from 0.01 to 100%, which professional and educated people can achieve the required results in just a few minutes.<\/p>\n<p>Unlike other Carl Fisher titrators, the Hana HI903 has a very precise dosing system and a special burette design to achieve results with unparalleled accuracy.<\/p>\n<p>A better experience than the Karl Fischer volumetric titrator<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":4431,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product\/4430"}],"collection":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/comments?post=4430"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media\/4431"}],"wp:attachment":[{"href":"https:\/\/sa-aria.com\/en\/wp-json\/wp\/v2\/media?parent=4430"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}